105 <strong>Electric</strong> strikes<br />

<strong>Model</strong> <strong>118</strong><br />

Accessories<br />

Control unit / relay / switchover device<br />

Automatic door strike control model 750<br />

Automatic electric strike control to ensure unrestricted<br />

public access despite locked door. For premises<br />

such as doctor <strong>and</strong> lawyer practices<br />

Technical attributes<br />

Mounting method<br />

Adjustable waiting time<br />

<strong>Electric</strong> strike release time<br />

Height<br />

Width<br />

Depth<br />

Supply voltage<br />

Surface-mounted/distributor<br />

installation<br />

Approx. 1 to 20 sec<br />

Approx. 1 to 10 sec<br />

98 mm<br />

88 mm<br />

63 mm<br />

8 - 12 V AC<br />

Feature<br />

Order no.<br />

Automatic door strike control 7 5 0 - - - - - - - - - - 0 0<br />

Time-delay relay model 770<br />

A simple <strong>and</strong> very practical way to keep the door strike<br />

unlocked at set times.<br />

Technical attributes<br />

Mounting method<br />

Period<br />

Height<br />

Width<br />

Depth<br />

Max. contact rating<br />

Surface-mounted/distributor<br />

installation<br />

0,25-1023 sec.<br />

98 mm<br />

88 mm<br />

63 mm<br />

24 V / 1 A<br />

Relay control model 7421<br />

Relay control in plastic casing for surface <strong>and</strong> top hat<br />

rail mounting (distributor installation). It consists of<br />

two relays with two potential-free change-over contacts<br />

<strong>and</strong> recovery diodes each.<br />

Feature<br />

Order no.<br />

12 V AC/DC rated operating voltage 7 7 0 - 1 0 - - - - - - E 1 0<br />

24 V AC/DC rated operating voltage 7 7 0 - 1 0 - - - - - - F 1 0<br />

Technical attributes<br />

Mounting method<br />

Switching voltage<br />

Switching current<br />

Surface-mounted/distributor<br />

installation<br />

230 V AC max.<br />

2 A max.<br />

Accessories<br />

Feature<br />

Order no.<br />

12 V DC rated operating voltage 7 4 2 1 - 1 2 - - - - - - 0 0<br />

24 V DC rated operating voltage 7 4 2 1 - 2 4 - - - - - - 0 0