104 <strong>Electric</strong> strikes<br />

<strong>Model</strong> <strong>118</strong><br />

Accessories<br />

Unrestricted public access despite locked door<br />

Switchover device model 7410-10<br />

For commercial buildings, offices, medical practices,<br />

schools <strong>and</strong> large apartment buildings<br />

The entrance door is permanently unlocked automatically<br />

at certain times during the day, enabling visitors<br />

to come <strong>and</strong> go as they wish. The system is controlled<br />

by a timer switch. The electric strike is permanently<br />

unlocked by a continuous current at the times set on<br />

the time switch (DC operation, electric strike makes<br />

no buzzing sound). Outside these set times, the electric<br />

strike operates as normal, i.e. electric strike<br />

released via the electric strike button in the apartment.<br />

(AC operation, electric strike makes no buzzing<br />

sound)<br />

Diagram of Functions<br />

12 V ~<br />

Switchover<br />

device<br />

Transformer<br />

230 V<br />

Timer switch<br />

A complete system consists of the following individual<br />

components:<br />

<strong>Electric</strong> strike with electric unlocking (only series 1<br />

models), switchover device, timer switch, transformerrectifier<br />

device, electric strike push-button.<br />

<strong>Electric</strong> strike push-button<br />

Accessories<br />

<strong>Electric</strong> strike:<br />

Always use a special electric strike model (series 1 models<br />

only, except model 17, 116), order with extra<br />

electric unlocking option (E3, F3), so the strike will be<br />

supplied with special spools for continuous energising.<br />

Installation:<br />

Plastic casing for surface-mount installation, or fit<br />

onto st<strong>and</strong>ard rail (distributor installation)<br />

<strong>Electric</strong> strike with ... electric unlocking<br />

Circuit diagram for electric strike system with automatic<br />

electric unlocking controlled via timer switch<br />

Switch<br />

8-24V AC<br />

Pushbutton<br />

Timer Switch<br />

1) Warning: A bridge must be installed between terminals 3 <strong>and</strong> 4 for an 8V input voltage.<br />

2) <strong>Electric</strong> strike (fail-locked) with electric unlocking (rated voltage according to connection voltage)<br />

Contact rating for relay contacts: 1A