14 Insulation Resistance<br />

Object:<br />

Same test set-up as used in clause 11 Contact Resistance.<br />

Test Set-Up:<br />

Test procedure according to IEC 60512-2 Test 3a<br />

Measuring Instrument:<br />

Test Parameter:<br />

METRISO C<br />

maximum measurable isolation resistance 100 GΩ<br />

test voltage 500V DC<br />

The insulation resistance was defined with > 10GΩ.<br />

Results:<br />

Minimum insulation resistance: 64.7GΩ<br />