13 Dielectric Strength<br />

Object:<br />

Same test set-up as used in clause 11 Contact Resistance. It was checked in<br />

completely mated, half mated and unmated condition. Each combination of<br />

contact to contact and contact to shell was judged.<br />

Test Set-Up:<br />

Test procedure according to IEC 60512-2 test 4a<br />

Measuring Instrument:<br />

Test Parameter:<br />

GOR-1 Dielectrometre<br />

0 – 6 kV<br />

The conditional value of dielectric strength was defined with > 1.5 kV.<br />

Results:<br />

Minimum dielectric strength: 2.0 kV<br />