13 Dielectric Strength<br />
Object:<br />
Same test set-up as used in clause 11 Contact Resistance. It was checked in<br />
completely mated, half mated and unmated condition. Each combination of<br />
contact to contact and contact to shell was judged.<br />
Test Set-Up:<br />
Test procedure according to IEC 60512-2 test 4a<br />
Measuring Instrument:<br />
Test Parameter:<br />
GOR-1 Dielectrometre<br />
0 – 6 kV<br />
The conditional value of dielectric strength was defined with > 1.5 kV.<br />
Results:<br />
Minimum dielectric strength: 2.0 kV<br />