U.S. Patent<br />

No. 7,779,581<br />

Proudly Made in<br />

the U.S.A.<br />

www.adatile.com • 800-372-0519


24.000<br />

21.600 9 - EQUAL SPACES<br />

1.200<br />

14.400<br />

PART O.A.<br />

36.000<br />

27.429<br />

PART O.A.<br />

B<br />

B<br />

1.200<br />

VIEW-D<br />

1.250<br />

TOP VIEW<br />

34.286<br />

15 - EQUAL SPACES<br />

SIDE VIEW<br />

SECTION B-B<br />

VIEW -B<br />

.090 DEG. POINTS<br />

.045 HIGH TYP.<br />

.450<br />

DIA. TOP OF DOMES<br />

0.245<br />

0.200<br />

.900<br />

DIA. TYP.<br />

60.000°<br />

1.375<br />

DIA.(6)<br />

1.125<br />

DIA.(6)<br />

CAP COVER<br />

0.6250<br />

(6)<br />

0.722<br />

0.562<br />

0.062<br />

0.875<br />

(6)<br />

0.500<br />

0.250<br />

0.967<br />

P.O. Box 3 • North Billerica, MA 01862<br />

R 0.250<br />

TYP.<br />

VIEW -B 3 x SIZE<br />

HEX HEAD BOLTS & WASHER 6-PL.<br />

Copyright © 2008-2011 <strong>ADA</strong> <strong>Solutions</strong>, <strong>Inc</strong>. All rights reserved.


<strong>ADA</strong> <strong>Product</strong>s Feature:<br />

Composite Detectable Warning Surfaces<br />

for Pedestrian Crossings<br />

Cast-In-Place Replaceable<br />

Radius Replaceable (WET-SET)<br />

Radius Surface Mount<br />

Surface Mount (Retrofit)<br />

Cast–In–Place (WET-SET)<br />

Cost Effective, Readily Available, and Easy to Install<br />

<strong>ADA</strong>AG/PROW/CA Title 24 Compliant<br />

– Pleasing architectural quality appearance and high performance product with geometry strictly<br />

compliant with all applicable codes.<br />

– Approved for use by all major municipalities, DPW’s and state DOT’s.<br />

Superior Wear Resistance<br />

– Wear resistance properties far superior to that achieved with concrete based materials of any type.<br />

– <strong>ADA</strong>’s product will conform to irregular underlying substrates.<br />

– Eliminates hairline cracking observed in epoxy based and VPC (Vitrified Polymer Composite)<br />

based materials.<br />

Maintenance<br />

– Virtually impervious to absorption (key indicator of durability) when compared to<br />

concrete, epoxy, or VPC materials. Not affected by chemical exposure.<br />

– Performs well when subjected to snow removal operations.<br />

– Easy to clean and replace when necessary.<br />

Homogenous Materials allow for Superior Color Stability<br />

– Pigment is uniformly distributed throughout the thickness of our products.<br />

– Long term color stability without the need for secondary coatings.<br />

<strong>Product</strong> Availability<br />

– Immediate delivery<br />

– National distribution<br />

Proudly Made in the U.S.A.<br />

We offer unmatched selection, service, delivery and price, with a strong focus on customer satisfaction.<br />

<strong>ADA</strong> <strong>Solutions</strong>, <strong>Inc</strong>. is leading the way in the detectable warning marketplace. Use us once and you’ll<br />

see why so many companies across the country choose <strong>ADA</strong> <strong>Solutions</strong>, <strong>Inc</strong>.<br />

In stock colors<br />

Yellow<br />

Brick<br />

Red<br />

Black<br />

Dark<br />

Gray<br />

Clay<br />

Red<br />

1. Federal Yellow #33538 (lusterless)<br />

2. Brick Red #20109 (lusterless)<br />

3. Black #37038 (lusterless)<br />

4. Dark Gray #36118 (lusterless)<br />

5. Clay Red #22144 (lusterless)<br />

6. Safety Red #31350 (lusterless)<br />

43.8<br />

7.3<br />

2.5<br />

2.5<br />

7.8<br />

8.6<br />

www.adatile.com • 800-372-0519<br />

1


REPLACEABLE<br />

RADIUS<br />

REPLACEABLE<br />

Varies<br />

RADIUS<br />

SURFACE<br />

MOUNT<br />

Varies<br />

2


USE OF CHEM LINK M-1 ® ADHESIVE/SEALANT TO INSTALL<br />

<strong>ADA</strong> TACTILE WARNING SURFACE & WAYFINDING PANELS<br />

<strong>ADA</strong> <strong>Solutions</strong>, <strong>Inc</strong>. offers the most complete and cost effective<br />

composite tactile warning surface (TWS) and wayfinding product line in<br />

the industry. <strong>ADA</strong> the North American market share leader. <strong>ADA</strong> offers<br />

Surface Applied (SA) TWS Panels, Cast-In-Place (CIP) TWS Units, and<br />

Replaceable (REP) TWS Units to meet your project requirements. <strong>ADA</strong>’s<br />

TWS products offer outstanding long-term performance, are slip<br />

resistant, offer superior long-term color stability, and can be installed<br />

with a minimum of effort under a wide variety of conditions. <strong>ADA</strong>’s<br />

products comply with <strong>ADA</strong>AG, PROW, and CATitle 24<br />

requirements. <strong>ADA</strong> recommends the use of Hydroment ®<br />

Ultra-Set ® Advanced and Durabond D-818 urethane<br />

adhesives for installation of its tactile warning surface<br />

and wayfinding products.<br />

TYPICAL PHYSICAL PROPERTIES<br />

V.O.C. Compliant<br />

Less than 20 grams/liter<br />

Color<br />

White, Gray<br />

Weight<br />

11.7 lbs per gallon<br />

Hardness<br />

45+3 Shore A Type<br />

Flash Point<br />

N/A<br />

Sheer Strength<br />

400 PSI<br />

Elongation 400-550%<br />

Low Temp Flex<br />

-10° F<br />

Cure Time<br />

24 hours<br />

Service Temperature<br />

Normal Use<br />

-40° F to 200° F<br />

Continuous Immersion<br />

120° F<br />

• LEED 2.2 for New <strong>Construction</strong> and Major<br />

Renovations: Low Emitting Materials (Section 4.1)<br />

1 Point<br />

• NAHB Model Green Home Building Guidelines:<br />

5 Global Impact Points<br />

• VOC Content at 240° F: less than 20 grams/liter<br />

(including water), ASTM D2369, EPA Method 24<br />

ADH5GAL<br />

3


Cast-In-Place (wet-set)<br />

Replaceable Tactile<br />

4


Proudly Made in<br />

the U.S.A.<br />

U.S. Patent<br />

No. 7,779,581<br />

5


Cast-In-Place Replaceable Tactile<br />

Installation Procedure<br />

Be sure to read and understand all of these instructions before you begin.<br />

A. The physical characteristics of the concrete shall be as specified in the contract<br />

documents while maintaining a slump range of 4-7 inches to permit the solid<br />

placement of the <strong>ADA</strong> Cast-In-Place Replaceable Tactile Unit (<strong>ADA</strong>REP) in the<br />

wet cement.<br />

B. The concrete shall be poured and finished level, true and smooth to<br />

the required dimensions prior to the placement of the <strong>ADA</strong>REP unit.<br />

C. Place the <strong>ADA</strong>REP unit 6-8 inches from the curb line. Working in a<br />

grid pattern, tamp the <strong>ADA</strong>REP unit into the wet concrete using a rubber<br />

mallet and a piece of wood. Continue this process until all of the air has<br />

been released, and the <strong>ADA</strong>REP unit surface is flush with the surrounding area.<br />

IMPORTANT: Avoid striking the surface of the <strong>ADA</strong>REP unit directly.<br />

D. Following the placement, the <strong>ADA</strong>REP unit elevation should be checked to<br />

the adjacent surface with a straight edge. The <strong>ADA</strong>REP unit elevation should<br />

be consistent with the Contract Drawings and Specifications. Any required<br />

adjustments must be made prior to the time when the concrete begins to set.<br />

E. Important Notice to Installer: To allow for expansion and contraction,<br />

after tile is installed, use a 1/4” finish edge trowel around entire perimeter. On a continous<br />

run, be sure to space each unit 1/8” apart.<br />

F. When you are confident that the <strong>ADA</strong>REP unit is in place and no further adjustments<br />

are needed, place a cinder block on both ends to hold the <strong>ADA</strong>REP unit in<br />

place while the concrete sets.<br />

G. During and after the <strong>ADA</strong>REP unit installation, as well as the concrete curing<br />

stage, no walking or external forces can be placed on the <strong>ADA</strong>REP unit. The area<br />

must be protected from pedestrian traffic until concrete is cured. The <strong>ADA</strong>REP<br />

Warning Surface will be ready for pedestrian traffic within 2-4 hours.<br />

H. Be sure to remove plastic<br />

protective covering from the face<br />

of the <strong>ADA</strong>REP Unit once the<br />

concrete is cured.<br />

*Not recommended or warrantied for<br />

asphalt installation.<br />

Do not cut Cast-In-Place Replaceable Tactile. Use an appropriate<br />

sized tactile or Radius Tactile to fit the requirement.<br />

Contact manufacturer for more details.<br />

PRODUCT SIZES<br />

2’x3’ 2’x4’ 2’x5’<br />

3’x4’ 3’x5’<br />

APPLICATION<br />

Fresh Pour<br />

Concrete Ramps<br />

& Replacement<br />

6<br />

www.adatile.com • 800-372-0519


Cast-In-Place Replaceable Tactile<br />

(WET-SET)<br />

Replacement Procedure<br />

Be sure to read and understand all of these<br />

instructions before you begin.<br />

A. Lift the existing composite bolt cap from each anchor location on the<br />

<strong>ADA</strong> Cast-In-Place Replaceable Tactile unit (<strong>ADA</strong>REP) with a flat head<br />

screw driver.<br />

B. Remove the existing 1/2” x 1½” stainless steel bolts from each anchor<br />

location on the <strong>ADA</strong>REP unit with a ratchet. Save & reuse.<br />

C. Tap around all sides of the <strong>ADA</strong>REP unit and across the middle with a<br />

rubber mallet, working in a grid pattern.<br />

D. Pry the existing <strong>ADA</strong>REP unit from the concrete ramp with a small<br />

prybar, working around the edges until it can be lifted cleanly away.<br />

E. Be sure to remove all small debris and dust from the existing impression<br />

in the concrete ramp.<br />

IMPORTANT: Be careful not to get debris into anchor locations.<br />

F. Replace new <strong>ADA</strong>REP unit, of same size and orientation, into impression<br />

in concrete ramp. Lightly tamp down the <strong>ADA</strong>REP unit with a rubber<br />

mallet and a piece of wood. Continue this process until the <strong>ADA</strong>REP unit<br />

is set firmly into existing impression in concrete ramp.<br />

IMPORTANT: Avoid striking the <strong>ADA</strong>REP unit directly.<br />

G. Bolt existing 1/2” x 1½” stainless steel bolts back into each anchor location<br />

on new <strong>ADA</strong>REP unit.<br />

H. Snap a new composite bolt cap provided, into each anchor location<br />

on the <strong>ADA</strong>REP unit. The <strong>ADA</strong>REP unit is ready for pedestrian<br />

traffic immediately after installation is complete.<br />

View additional photos, drawings and<br />

specifications on our website: www.adatile.com.<br />

Call (800) 372-0519 with any questions.<br />

U.S. Patent<br />

No. 7,779,581<br />

www.adatile.com • 800-372-0519<br />

7


24.0<br />

21.6<br />

14.4<br />

PATENT PENDING<br />

B<br />

B<br />

Cast-In-Place Replaceable Tactile<br />

DOME GEOMETRY<br />

In accordance with <strong>ADA</strong> Regulations for Detectable Warning on Curb Ramps: Raised<br />

truncated domes with a diameter of nominal 0.9”, a height of nominal 0.2” and a<br />

center-to-center spacing of 2.35”.<br />

PANEL DIMENSIONS<br />

VIEW -B<br />

.090<br />

<strong>ADA</strong> Cast-In-Place .045<br />

DEG. HIGH POINTS<br />

Replaceable TYP. .900 Tactile units (<strong>ADA</strong>REP) are available in 24” x 36”,<br />

DIA. TYP.<br />

24” x 48”, 24” x 60”, .500<br />

60.000°<br />

DIA. TOP<br />

36”<br />

OF<br />

x<br />

DOMES<br />

48” and 36” x 60” sizes. <strong>ADA</strong>REP units may also be custom<br />

1.375<br />

configured to accommodate specific project DIA.(4) requirements. <strong>ADA</strong>REP units measure<br />

1.125<br />

DIA.(4)<br />

¼” nominal thickness and feature a ⅜” thick x 1” wide perimeter “flange.”<br />

MATERIAL<br />

1.250<br />

Inline Dome Pattern<br />

VIEW-D<br />

15 - EQUAL SPACES NOTE: US PATENT PENDING APPEARS ON<br />

TOP SIDE OF PART AS SHOWN.<br />

AIR VENTS AROUND THE<br />

OUTSIDE EDGES OF PANEL<br />

2.350<br />

A homogenous glass and carbon composite which is colorfast and UV stable.<br />

Truncated domes are fiberglass reinforced for enhanced durability. The color of the<br />

<strong>ADA</strong>REP unit is uniform throughout and does not rely R0.250 on any type of paint coating to achieve color stability. Standard colors<br />

TYP.<br />

include: Federal Yellow, Brick Red, Clay Red, Safety Red, Blue, Dark Gray and Black. For superior wheelchair, walker and<br />

HEX HEAD BOLTS & WASHER 4-PL.<br />

shopping cart mobility, truncated domes have a center-to-center (horizontally and vertically) spacing of 2.35 inches.<br />

0.870<br />

0.245<br />

0.200<br />

0.625<br />

0.312<br />

0.062<br />

0.250<br />

34.286<br />

CAP COVER<br />

0.6250<br />

(4)<br />

0.875<br />

(4)<br />

PHYSICAL CHARACTERISTICS<br />

Compressive Strength 28,900 psi ASTM D 695<br />

Flexural Strength 29,300 psi ASTM D 790<br />

Water Absorption .07% ASTM D 570<br />

Slip Resistance 1.18 Dry, 1.05 Wet ASTM C 1028<br />

Flame Spread Index 20 ASTM E 84<br />

Salt Spray No Change (200 hours) ASTM B 117<br />

Chemical Stain Testing No Deterioration ASTM 1308<br />

Abrasion Resistance 549 ASTM C 501<br />

Accelerated Weathering Delta E


Cast-In-Place Replaceable Tactile<br />

(WET-SET)<br />

24”x36” Tile<br />

2.35” Dome Spacing<br />

VIEW -B<br />

.090 DEG. POINTS<br />

.045 HIGH TYP.<br />

.450<br />

DIA. TOP OF DOMES<br />

.900<br />

DIA. TYP.<br />

1.375<br />

DIA.(8)<br />

1.125<br />

DIA.(8)<br />

VIEW -B 3 x SIZE<br />

CAP COVER<br />

0.6250<br />

(8)<br />

0.875<br />

(8)<br />

TOP VIEW<br />

34.286<br />

15 - EQUAL SPACES<br />

SIDE VIEW<br />

A<br />

R0.250<br />

TYP.<br />

HEX HEAD BOLTS & WASHER 8-PL.<br />

AIR VENTS LOCATED ON<br />

THE ENDS OF THE TWS UNIT<br />

BOTTOM VIEW<br />

9 - EQUAL SPACES<br />

21.600 1.200<br />

A<br />

US<br />

60.000°<br />

PATENT # 7,779,581<br />

24.000<br />

14.400<br />

0.062<br />

0.250<br />

1.250<br />

NOTE: U.S. PATENT # 7,779,581 APPEARS ON<br />

TOP SIDE OF PART AS SHOWN.<br />

2.350<br />

WWW.<strong>ADA</strong>TILE.COM<br />

U.S. PATENT<br />

# 7,779,581<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

(800)372-0519<br />

P.O. Box 3<br />

N.Billerica, Ma. 01862<br />

2.350<br />

VIEW-D<br />

36.000<br />

27.429<br />

SECTION A-A<br />

VIEW - " D" 2 x SIZE<br />

FIELD DOT 7 DOME LAYOUT<br />

TRADE PART NO.<br />

TACTILE WARNING SURFACE 2436NV8REP_<br />

MATERIAL<br />

SMC COMPOSITE<br />

PROJECT<br />

WET SET <strong>ADA</strong> STD REPLACEABLE TACTILE<br />

WARNING SURFACE UNIT<br />

8-BOLT LOCATIONS<br />

2.350" IN LINE TRUNCATED DOME PATTERN<br />

PART SIZE 24" x 36"<br />

PLANS AND DETAILS<br />

DRAWING NO.<br />

DATE<br />

<strong>ADA</strong>-REP2436<br />

1.200<br />

0.722<br />

0.967<br />

0.245<br />

0.200<br />

0.500<br />

0.22<br />

www.adatile.com • 800-372-0519<br />

9


Cast-In-Place Replaceable Tactile<br />

24”x48” Tile<br />

2.35” Dome Spacing<br />

VIEW -B 3 x SIZE<br />

HEX HEAD BOLTS & WASHER 8-PL.<br />

R 0.250<br />

TYP.<br />

0.722<br />

0.062<br />

0.500<br />

0.250<br />

(8)<br />

1.375<br />

DIA. (8)<br />

1.125<br />

DIA. (8)<br />

0.6250<br />

(8)<br />

0.875<br />

(8)<br />

.450<br />

DIA. TOP OF DOMES<br />

0.967 24.000<br />

1.200<br />

21.600<br />

0.245<br />

14.400<br />

0.200<br />

0.22<br />

60.000°<br />

.090 DEG. POINTS<br />

.045 HIGH TYP.<br />

.900<br />

DIA. TYP.<br />

CAP COVER<br />

VIEW -B<br />

SECTION A-A<br />

SIDE VIEW<br />

VIEW-D<br />

20 - EQUAL SPACES<br />

45.714<br />

1.250<br />

TOP VIEW<br />

A<br />

US<br />

9 - EQUAL SPACES<br />

1.200<br />

18.286 20.571<br />

9.1429 2.286 9.1429<br />

48.000<br />

PATENT # 7,779,581<br />

VIEW - " D" 2 x SIZE<br />

FIELD DOT 7 DOME LAYOUT<br />

2.350<br />

2.350<br />

NOTE: U.S. PATENT # 7,779,581 APPEARS ON<br />

TOP SIDE OF PART AS SHOWN.<br />

AIR VENTS LOCATED ON<br />

THE ENDS OF THE TWS UNIT<br />

A<br />

BOTTOM VIEW<br />

WWW.<strong>ADA</strong>TILE.COM<br />

U.S. PATENT<br />

# 7,779,581<br />

TRADE PART NO.<br />

TACTILE WARNING SURFACE 2448NV8REP_<br />

MATERIAL<br />

SMC COMPOSITE<br />

PROJECT<br />

WET SET <strong>ADA</strong> REPLACEABLE TACTILE<br />

WARNING SURFACE UNIT<br />

8-BOLT LOCATIONS<br />

2.350" IN LINE TRUNCATED DOME PATTERN<br />

PART SIZE 24" x 48"<br />

PLANS AND DETAILS<br />

DRAWING NO.<br />

DATE<br />

<strong>ADA</strong>-REP2448<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

(800)372-0519<br />

P.O. Box 3<br />

N.Billerica, Ma. 01862<br />

10<br />

www.adatile.com • 800-372-0519


Cast-In-Place Replaceable Tactile<br />

(WET-SET)<br />

24”x60” Tile<br />

2.35” Dome Spacing<br />

0.722<br />

0.062<br />

0.500<br />

0.250<br />

(11)<br />

0.6250<br />

(11)<br />

0.875<br />

(11)<br />

9 - EQUAL SPACES<br />

B<br />

TOP VIEW<br />

1.250<br />

57.143<br />

25 - EQUAL SPACES<br />

SIDE VIEW<br />

VIEW -B<br />

CAP COVER<br />

.090 DEG. POINTS<br />

.045 HIGH TYP.<br />

.900<br />

DIA. TYP. 60.000°<br />

.450<br />

DIA. TOP OF DOMES<br />

1.375<br />

DIA.(11)<br />

1.125<br />

DIA.(11)<br />

R0.250<br />

TYP.<br />

HEX HEAD BOLTS & WASHER 11-PL.<br />

VIEW -B 3 x SIZE<br />

US PATENT # 7,779,581<br />

B<br />

AIR VENTS LOCATED ON<br />

THE ENDS OF THE PANEL<br />

BOTTOM VIEW<br />

0.967<br />

24.000<br />

21.600<br />

14.400<br />

1.200<br />

2.350<br />

60.000<br />

18.286 13.714 18.286<br />

6.314 6.314<br />

VIEW-D<br />

SECTION B-B<br />

NOTE: U.S. PATENT # 7,779,581 APPEARS ON<br />

TOP SIDE OF PART AS SHOWN.<br />

2.350<br />

VIEW - " D" 2 x SIZE<br />

FIELD DOT 7 DOME LAYOUT<br />

WWW.<strong>ADA</strong>TILE.COM<br />

U.S. PATENT<br />

# 7,779,581<br />

TRADE PART NO.<br />

TACTILE WARNING SURFACE 2460NV11REP_<br />

MATERIAL<br />

SMC COMPOSITE<br />

PROJECT<br />

WET SET <strong>ADA</strong> REPLACEABLE TACTILE<br />

WARNING SURFACE UNIT<br />

11-BOLT LOCATIONS<br />

2.350" IN LINE TRUNCATED DOME PATTERN<br />

PART SIZE 24" x 60"<br />

PLANS AND DETAILS<br />

DRAWING NO.<br />

DATE<br />

<strong>ADA</strong>-REP2460<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

(800)372-0519<br />

P.O. Box 3<br />

N.Billerica, Ma. 01862<br />

0.245<br />

0.200<br />

0.22<br />

1.200<br />

www.adatile.com • 800-372-0519<br />

11


Cast-In-Place Replaceable Tactile<br />

36”x48” Tile<br />

2.35” Dome Spacing<br />

VIEW-D<br />

1.125<br />

36.000<br />

PART O.A.<br />

33.750 1.125<br />

15 - EQUAL SPACES<br />

VIEW -B 3 x SIZE<br />

HEX HEAD BOLTS & WASHER 12-PL.<br />

R 0.250<br />

TYP.<br />

0.562<br />

0.062<br />

0.250<br />

(12)<br />

0.722<br />

0.500<br />

0.967<br />

0.245<br />

0.200<br />

1.375<br />

DIA. (12)<br />

1.125<br />

DIA. (12)<br />

0.6250<br />

(12)<br />

0.875<br />

(12)<br />

.450<br />

DIA. TOP OF DOMES<br />

60.000°<br />

.090 DEG. POINTS<br />

.045 HIGH TYP.<br />

.900<br />

DIA. TYP.<br />

CAP COVER<br />

VIEW-B<br />

SECTION B-B<br />

SIDE VIEW<br />

AIR VENTS AROUND THE<br />

OUTSIDE EDGES OF PANEL<br />

20 - EQUAL SPACES<br />

45.714<br />

1.143<br />

1.143<br />

A A<br />

13.500 13.500<br />

18.286 20.571<br />

2.286<br />

PART O.A.<br />

48.000<br />

VIEW - " D" 2 x SIZE<br />

FIELD DOT 13 ON DOME LAYOUT<br />

2.350<br />

2.350<br />

NOTE: US PATENT PENDING APPEARS ON<br />

TOP SIDE OF PART AS SHOWN.<br />

BOTTOM VIEW<br />

WWW.<strong>ADA</strong>TILE.COM<br />

U.S. Patent No.7,779,581<br />

MATERIAL LIST<br />

ITEM<br />

DESCRIPTION<br />

PART NO. QT'Y<br />

1<br />

2<br />

3<br />

4<br />

SCALE<br />

AS NOTED<br />

FULL SIZE<br />

TRADE<br />

DETECTABLE WARNING SURFACE<br />

PART NO.<br />

SEE MATERIAL LIST<br />

MATERIAL<br />

PROJECT<br />

WET SET <strong>ADA</strong> REPLACEABLE TACTILE<br />

WARNING SURFACE UNIT<br />

2.375" IN LINE TRUNCATED DOME PATTERN<br />

PART SIZE 36" x 48"<br />

PLANS AND DETAILS<br />

DRAWING NO. REV. NO.<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

P.O. Box 3<br />

N.Billerica, Ma. 01862<br />

12<br />

www.adatile.com • 800-372-0519


NOTE: US PATENT PENDING APPEARS ON<br />

TOP SIDE OF PART AS SHOWN.<br />

2.350<br />

2.350<br />

VIEW - " D" 2 x SIZE<br />

FIELD DOT 13 ON DOME LAYOUT<br />

BOTTOM VIEW<br />

U.S. Patent No.7,779,581<br />

MATERIAL LIST<br />

ITEM<br />

DESCRIPTION<br />

PART NO. QT'Y<br />

SCALE<br />

AS NOTED<br />

FULL SIZE<br />

TRADE<br />

PART NO.<br />

DETECTABLE WARNING SURFACE<br />

SEE MATERIAL LIST<br />

MATERIAL<br />

PROJECT<br />

WET SET <strong>ADA</strong> REPLACEABLE TACTILE<br />

WARNING SURFACE UNIT<br />

2.375" IN LINE TRUNCATED DOME PATTERN<br />

PART SIZE 36" x 60"<br />

PLANS AND DETAILS<br />

DRAWING NO. REV. NO.<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

P.O. Box 3<br />

N.Billerica, Ma. 01862<br />

1<br />

2<br />

3<br />

4<br />

Cast-In-Place Replaceable Tactile<br />

(WET-SET)<br />

36x60” Tile<br />

2.35” Dome Spacing<br />

1.125<br />

36.000<br />

PART O.A.<br />

33.750 1.125<br />

15 - EQUAL SPACES<br />

13.500 13.500<br />

"B"<br />

VIEW-D<br />

59.429<br />

16.000 18.286 16.000<br />

1.143 1.143<br />

57.143<br />

20 - EQUAL SPACES<br />

SIDE VIEW<br />

AIR VENTS AROUND THE<br />

OUTSIDE EDGES OF PANEL<br />

SECTION B-B<br />

VIEW-B<br />

"B"<br />

0.722<br />

0.562<br />

0.062<br />

0.500<br />

0.250<br />

(12)<br />

0.967<br />

0.245<br />

0.200<br />

0.6250<br />

(12)<br />

0.875<br />

(12)<br />

.090 DEG. POINTS<br />

.045 HIGH TYP.<br />

.900<br />

DIA. TYP.<br />

60.000°<br />

.450<br />

DIA. TOP OF DOMES<br />

1.375<br />

DIA. (12)<br />

1.125<br />

DIA. (12)<br />

CAP COVER<br />

R 0.250<br />

TYP.<br />

VIEW -B 3 x SIZE<br />

HEX HEAD BOLTS & WASHER 12-PL.<br />

WWW.<strong>ADA</strong>TILE.COM<br />

www.adatile.com • 800-372-0519<br />

13


U.S. Patent<br />

No. 7,779,581<br />

Radius Tactile<br />

cast-in-place replaceable (wet-set)<br />

or surface mount<br />

14


Proudly Made in<br />

the U.S.A.<br />

15


Radius Tactile - Replaceable<br />

Installation Procedure<br />

Be sure to read and understand all of these<br />

instructions before you begin.<br />

A. The physical characteristics of the concrete shall be as specified in the contract<br />

documents while maintaining a slump range of 4-7 inches to permit the solid<br />

placement of the <strong>ADA</strong> Replaceable Tactile Unit (<strong>ADA</strong>REP) in the wet cement.<br />

B. The concrete shall be poured and finished level, true and smooth to the<br />

required dimensions prior to the placement of the <strong>ADA</strong>REP unit.<br />

C. Working in a grid pattern, tamp the <strong>ADA</strong>REP unit into the wet concrete<br />

using a rubber mallet and a piece of wood. Continue this process until all of the air<br />

has been released, and the <strong>ADA</strong>REP unit surface is flush with the surrounding area.<br />

IMPORTANT: Avoid striking the surface of the <strong>ADA</strong>REP unit directly.<br />

D. Following the placement, the <strong>ADA</strong>REP unit elevation should be checked to<br />

the adjacent surface with a straight edge. The <strong>ADA</strong>REP unit elevation should<br />

be consistent with the Contract Drawings and Specifications. Any required<br />

adjustments must be made prior to the time when the concrete begins to set.<br />

E. Important Notice to Installer: To allow for expansion and contraction,<br />

after tile is installed, use a 1/4” finish edge trowel around entire perimeter. On a continous<br />

run, be sure to space each unit 1/8” apart.<br />

F. When you are confident that the <strong>ADA</strong>REP unit is in place and no further<br />

adjustments are needed, place a cinder block on both ends to hold the <strong>ADA</strong>REP<br />

unit in place while the concrete sets.<br />

G. During and after the <strong>ADA</strong>REP unit installation, as well as the concrete curing<br />

stage, no walking or external forces can be placed on the <strong>ADA</strong>REP unit. The area<br />

must be protected from pedestrian traffic until concrete is cured. The <strong>ADA</strong>REP<br />

Warning Surface will be ready for pedestrian traffic within 2-4 hours.<br />

H. Be sure to remove plastic protective<br />

covering from the face of the <strong>ADA</strong>REP<br />

Unit once the concrete is cured.<br />

*Not recommended or warrantied for<br />

asphalt installation.<br />

View additional photos, drawings and specifications<br />

on our website: www.adatile.com.<br />

Call (800) 372-0519 with any questions.<br />

PRODUCT SIZES<br />

2’ x 33¼”<br />

APPLICATION<br />

Fresh Pour<br />

Concrete Ramps<br />

& Replacement<br />

16<br />

www.adatile.com • 800-372-0519


Radius Tactile - Replaceable<br />

(WET-SET)<br />

Replacement Procedure<br />

Be sure to read and understand all of these<br />

instructions before you begin.<br />

A. Lift the existing composite bolt cap from each anchor location on the <strong>ADA</strong><br />

Replaceable Tactile unit (<strong>ADA</strong>REP) with a flat head screw driver.<br />

B. Remove the existing 1/2” x 1½” stainless steel bolts from each anchor location<br />

on the <strong>ADA</strong>REP unit with a ratchet. Save & reuse.<br />

C. Tap around all sides of the <strong>ADA</strong>REP unit and across the middle with a rubber<br />

mallet, working in a grid pattern.<br />

D. Pry the existing <strong>ADA</strong>REP unit from the concrete ramp with a small<br />

prybar, working around the edges until it can be lifted cleanly away.<br />

E. Be sure to remove all small debris and dust from the existing impression<br />

in the concrete ramp.<br />

IMPORTANT: Be careful not to get debris into anchor locations.<br />

F. Replace new <strong>ADA</strong>REP unit into impression in concrete ramp. Lightly<br />

tamp down the <strong>ADA</strong>REP unit with a rubber mallet and a piece of wood.<br />

Continue this process until the <strong>ADA</strong>REP unit is set firmly into existing<br />

impression in concrete ramp.<br />

IMPORTANT: Avoid striking the <strong>ADA</strong>REP unit directly.<br />

G. Bolt existing 1/2” x 1½” stainless steel bolts back into each anchor location<br />

on new <strong>ADA</strong>REP unit.<br />

H. Snap a new composite bolt cap provided, into each anchor location<br />

on the <strong>ADA</strong>REP unit. The <strong>ADA</strong>REP unit is ready for pedestrian<br />

traffic immediately after installation is complete.<br />

View additional photos, drawings and<br />

specifications on our website: www.adatile.com.<br />

Call (800) 372-0519 with any questions.<br />

U.S. Patent<br />

No. 7,779,581<br />

www.adatile.com • 800-372-0519<br />

17


Radius Tactile - Replaceable<br />

Inline Dome Pattern<br />

DOME GEOMETRY<br />

<strong>ADA</strong>AG, PROWAG and <strong>ADA</strong>/ABA Compliant in-line truncated dome pattern.<br />

UNIVERSAL RADIUS TWS PRODUCT<br />

Universal Radius TWS <strong>Product</strong> is scored for a 10’, 15’ and 20’ radial condition and may be cut by a table saw to<br />

accommodate site conditions.<br />

Radius Panel Sizes<br />

• <strong>ADA</strong> Replaceable TWS Unit: 24” x 33¼”, 6 recessed and capped ½” x 1½” bolts with concrete inserts and heavy duty<br />

perimeter detail.<br />

MATERIAL<br />

A homogenous glass and carbon reinforced composite which is colorfast and UV stable. Truncated domes are fiberglass<br />

reinforced for enhanced durability. The color of the TWS Unit is uniform throughout and does not rely on any type of<br />

paint coating to achieve color stability. Standard colors: Federal Yellow, Brick Red, Clay Red, Safety Red, Blue, Dark<br />

Gray, and Black.<br />

PHYSICAL CHARACTERISTICS<br />

Compressive Strength 28,900 psi ASTM D 695<br />

Flexural Strength 29,300 psi ASTM D 790<br />

Slip Resistance 1.18 Dry, 1.05 Wet ASTM C 1028<br />

Chemical Stain Testing No Deterioration ASTM D 543<br />

Abrasion Resistance 549 ASTM C 501<br />

Accelerated Weathering Delta E


Radius Tactile - Replaceable<br />

(WET-SET)<br />

24”x33.25” Tile<br />

2.35” Dome Spacing<br />

33.252<br />

REF. DIM BEFORE CUT<br />

VIEW - D TOP VIEW<br />

8-BOLT LOCATIONS<br />

FRONT VIEW<br />

SECTION A-A<br />

SIDE VIEW<br />

VIEW-E 2 x SIZE<br />

VIEW-E<br />

BOTTOM VIEW<br />

1.700<br />

2.350<br />

A<br />

A<br />

.090 DEG. POINTS<br />

.045 HIGH TYP.<br />

0.450<br />

DIA. TOP OF DOMES<br />

0.900<br />

DIA. TYP.<br />

60°0'<br />

LABELED RADIUS<br />

CUT LINES FOR<br />

10', 15', 20' RADIAL<br />

CAP COVER<br />

R0.250<br />

TYP.<br />

HEX HEAD BOLTS & WASHER 8-PL.<br />

0.967<br />

0.722<br />

0.160<br />

0.875<br />

(8)<br />

0.625<br />

(8)<br />

24.000<br />

0.159<br />

VIEW-B 3 x SIZE<br />

'A' DIMENSION AFTER CUT<br />

SEE CHART<br />

'B' DIMENSION AFTER CUT<br />

SEE CHART<br />

VIEW - " D" 2 x SIZE<br />

FIELD DOT 13 ON DOME LAYOUT<br />

WWW.<strong>ADA</strong>TILE.COM<br />

U.S. PATENT<br />

# 7,779,581<br />

+ PATENT PENDING<br />

WET SET <strong>ADA</strong> STD REPLACEABLE TACTILE<br />

WARNING SURFACE UNIT<br />

8-BOLT LOCATIONS<br />

2.350" IN LINE TRUNCATED DOME PATTERN<br />

PART SIZE 24" x 10', 15', 20' RADIAL<br />

PLANS AND DETAILS<br />

<strong>ADA</strong>-REP24RAD<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

(800)372-0519<br />

P.O. Box 3<br />

N.Billerica, Ma. 01862<br />

0.715<br />

(8)<br />

10' RADIUS<br />

11.280<br />

10.392<br />

1.375<br />

DIA.(8)<br />

1.125<br />

DIA.(8)<br />

TRADE PART NO.<br />

TACTILE WARNING SURFACE 24RAD8REP_<br />

MATERIAL<br />

SMC COMPOSITE<br />

PROJECT<br />

DRAWING NO.<br />

DATE<br />

11.280<br />

14.375<br />

10.392<br />

0.563<br />

0.062<br />

0.245<br />

0.200<br />

DOMES<br />

www.adatile.com • 800-372-0519<br />

19


Radius Tactile - Surface Mount<br />

Installation Procedure<br />

Be sure to read and understand all of these instructions before you begin.<br />

A. The installation area should be cleaned of all debris, oil and grease, making<br />

sure the area is completely free of moisture. Tactile Panel may be surface<br />

mounted on existing pre-cleaned substrate.<br />

B. Lay out the Tactile Panel on the substrate as it will appear when installed.<br />

• If required, the Tactile Panel may be cut using a table saw and diamond<br />

tipped blade. 10’, 15’, & 20’ radius are pre-scored on backside of tactile<br />

panel. See web site for more details.<br />

C. Place a 3/8” bead of adhesive on the frame of the bottom of each Tactile<br />

Panel. Adhesive yield: 10SF per 10 ounce cartridge. 18-24SF per 20 ounce<br />

cartridge.<br />

D. Set the Tactile Panel in the installation area. Make all necessary adjustments<br />

prior to fastening.<br />

E. Fasteners shall be installed in pre-formed fastener locations. Holes shall be<br />

drilled using a hammer drill with 1/4” x 2” min SDS bits. The drilled holes<br />

must be a minimum of 2” deep. Place fasteners in hole and hammer into<br />

place.<br />

• If additional fasteners are required, use a 1/2”, six point, 82 degree<br />

countersink to add a new fastener location. Follow the same drilling<br />

method for installing the fastener.<br />

F. Caulk around perimeter of entire installation using BASF NP1 or<br />

equivalent.<br />

• All concrete dust present on the Tactile Panel resulting from the drilling<br />

process must be cleaned off of the Tactile Panel prior to using any<br />

caulking materials.<br />

*Not recommended or warrantied for asphalt installation.<br />

View additional photos, drawings and specifications on our website:<br />

www.adatile.com. Call (800) 372-0519 with any questions.<br />

PRODUCT SIZES<br />

2’ x 33¼”<br />

APPLICATION<br />

Existing<br />

Concrete Ramps<br />

www.adatile.com • 800-372-0519<br />

21


Radius Tactile - Surface Mount<br />

Inline Dome Pattern<br />

DOME GEOMETRY<br />

<strong>ADA</strong>AG, PROWAG and <strong>ADA</strong>/ABA Compliant in-line truncated dome pattern.<br />

UNIVERSAL RADIUS TWS Panel<br />

Universal Radius TWS Panel is scored on backside for a 10’, 15’ and 20’ radial condition and may be cut by a table saw<br />

to accommodate site conditions.<br />

Radius Panel Sizes<br />

• <strong>ADA</strong> Surface Applied TWS Panel: 24” x 33¼”, 16 composite sleeve anchors with stainless steel pins, adhesive &<br />

perimeter sealant.<br />

MATERIAL<br />

A homogenous glass and carbon reinforced composite which is colorfast and UV stable. Truncated domes are fiberglass<br />

reinforced for enhanced durability. The color of the TWS Unit is uniform throughout and does not rely on any type of<br />

paint coating to achieve color stability. Standard colors: Federal Yellow, Brick Red, Clay Red, Safety Red, Blue, Dark<br />

Gray, and Black.<br />

PHYSICAL CHARACTERISTICS<br />

Compressive Strength 28,900 psi ASTM D 695<br />

Flexural Strength 29,300 psi ASTM D 790<br />

Slip Resistance 1.18 Dry, 1.05 Wet ASTM C 1028<br />

Chemical Stain Testing No Deterioration ASTM D 543<br />

Abrasion Resistance 549 ASTM C 501<br />

Accelerated Weathering Delta E


Radius Tactile - Surface Mount<br />

24”x33.25” Tile<br />

2.35” Dome Spacing<br />

33.260<br />

REF DIM BEFORE CUT<br />

A<br />

27.500<br />

REF DIM BEFORE CUT<br />

VIEW A<br />

16- ANCHOR LOCATIONS<br />

LABELED RADIUS<br />

CUT LINES<br />

.005 RAISED LETTERS<br />

.045 RAISED CUT LINES<br />

.436<br />

DIA<br />

70.0°<br />

16-PL<br />

1/4" x 1 1/2" LG.<br />

EXPANSION ANCHOR<br />

.900<br />

DIA. 150-PL<br />

MATERIAL LIST<br />

ITEM<br />

DESCRIPTION<br />

PART NO. QT'Y<br />

1<br />

2<br />

3<br />

4<br />

SCALE<br />

AS NOTED<br />

FULL SIZE<br />

TRADE<br />

PART NO.<br />

DETECTABLE WARNING SURFACE SEE MATERIAL LIST<br />

MATERIAL<br />

PROJECT<br />

24" X 10', 15', 20' RADIAL<br />

SOUND ATTENUATING<br />

CURB RAMP TILE 2.350" (INLINE DOME)<br />

PLANS AND DETAILS<br />

DRAWING NO. REV. NO.<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

P.O. Box 3<br />

N.Billerica, Ma. 01862<br />

45.0°<br />

VIEW B 2X SCALE<br />

TILE INSTALLATION<br />

VIEW-B 4x SCALE<br />

2.350<br />

24.000<br />

.432<br />

O.A.<br />

.188<br />

PANEL<br />

.045<br />

POINTS<br />

.200<br />

DOME 150-PL<br />

.188<br />

PANEL<br />

.045<br />

CUT LINE<br />

A<br />

TOP VIEW<br />

FRONT VIEW<br />

VIEW B<br />

SECTION A-A<br />

1.700<br />

VIEW A 2X SCALE<br />

VIEW C<br />

SIDE VIEW BOTTOM VIEW<br />

VIEW C 2X SCALE<br />

WWW.<strong>ADA</strong>TILE.COM<br />

<strong>ADA</strong> SURFACE PANEL APPLIED<br />

DETECTABLKE TWS<br />

www.adatile.com • 800-372-0519<br />

23


Surface Mount<br />

Tactile<br />

24


Proudly Made in<br />

the U.S.A.<br />

25


Surface Mount Tactile<br />

Installation Procedure<br />

Be sure to read and understand all of these<br />

instructions before you begin.<br />

A. The installation area should be cleaned of all debris, oil and grease, making<br />

sure the area is completely free of moisture. Tactile Panel may be surface<br />

mounted on existing pre-cleaned substrate.<br />

B. Lay out the Tactile Panel on the substrate as it will appear when installed.<br />

• If required, the Tactile Panel may be cut using a table saw and marble<br />

tipped blade. See web site for more details.<br />

C. Place a 3/8” bead of adhesive on the frame of the bottom of each Tactile<br />

Panel. Adhesive yield: 10SF per 10 ounce cartridge.<br />

D. Set the Tactile Panel in the installation area. Make all necessary adjustments<br />

prior to fastening.<br />

E. Fasteners shall be installed in pre-formed fastener locations. Holes shall be<br />

drilled using a hammer drill with 1/4” x 2” min SDS bits. The drilled holes<br />

must be a minimum of 2” deep. Place fasteners in hole and hammer into place.<br />

• If additional fasteners are required, use a 1/2”, six point, 82 degree<br />

countersink to add a new fastener location. Follow the same drilling<br />

method for installing the fastener.<br />

F. Caulk around perimeter of entire installation using BASF NP1 or equivalent.<br />

• All concrete dust present on the Tactile Panel resulting from the drilling<br />

process must be cleaned off of the Tactile Panel prior to using any<br />

caulking materials.<br />

*Not recommended or warrantied for asphalt installation.<br />

PRODUCT SIZES<br />

2’x3’ 2’x4’ 2’x5’<br />

3’x4’ 3’x5’<br />

View additional photos, drawings and specifications<br />

on our website: www.adatile.com.<br />

Call (800) 372-0519 with any questions.<br />

APPLICATION<br />

Existing<br />

Concrete Ramps<br />

26<br />

www.adatile.com • 800-372-0519


DOME GEOMETRY<br />

In accordance with <strong>ADA</strong> Regulations for Detectable Warning<br />

on Curb Ramps: Raised truncated domes with a diameter<br />

of nominal 0.9”, a height of nominal 0.2”, and a centerto-center<br />

spacing of nominal 1.67” minimum and 2.35”<br />

maximum.<br />

PANEL DIMENSIONS<br />

Tactile Panels are available in 24”x36”, 24”x48”, 24”x60”,<br />

36”x48” and 36”x60” sizes and measure 3/16” thick. Panels<br />

can be custom cut to fit field conditions. All four edges of<br />

each panel have a ½” beveled edge. Each panel has 12 to<br />

24 pre-formed fastener locations based upon panel size.<br />

MATERIAL<br />

A homogenous glass and carbon reinforced composite which is colorfast and UV stable. Truncated domes are fiberglass<br />

reinforced for enhanced durability. The Tactile panel color is uniform throughout and does not rely on any type of paint<br />

coating to achieve color stability. Standard colors include: Federal Yellow, Brick Red, Clay Red, Safety Red, Blue, Dark<br />

Gray and Black.<br />

PHYSICAL CHARACTERISTICS<br />

Compressive Strength 28,900 psi ASTM D 695<br />

Flexural Strength 29,300 psi ASTM D 790<br />

Water Absorption .07% ASTM D 570<br />

Slip Resistance 1.18 Dry/1.05 Wet ASTM C 1028<br />

Flame Spread Index 20 ASTM E 84<br />

Salt Spray No Change (200 hours) ASTM B 117<br />

Chemical Stain Testing No Deterioration ASTM 1308<br />

Abrasion Resistance 549 ASTM C 501<br />

Accelerated Weathering Delta E


790<br />

1<br />

2<br />

3<br />

4<br />

Surface Mount Composite Tactile<br />

24”x36” Tile<br />

1.67” Dome Spacing<br />

24.2812<br />

PART O.A.<br />

1.2971<br />

1.6700<br />

13 - 13 EQUAL SPACES<br />

0.4425<br />

PART O.A.<br />

1.286<br />

21.709<br />

13 - EQUAL SPACES<br />

1.286<br />

R.1250<br />

4-PL.<br />

"B"<br />

0.1350<br />

WALL THICKNESS<br />

R.125<br />

4-PL.<br />

1/4" DIA. CTSK HOLES<br />

(TYP. 12 LOCATIONS)<br />

1.1467<br />

1.6700<br />

VIEW-A 4 x SCALE<br />

37.3700<br />

PART O.A.<br />

HALF SCALE<br />

1/4" DIA. CTSK HOLES<br />

(TYP. 12 LOCATIONS)<br />

"B"<br />

30°<br />

.1975<br />

.0625<br />

.7500<br />

300<br />

.200<br />

18-PL.<br />

.500<br />

4-SIDES<br />

.900<br />

DIA. 260 PL.<br />

.0625<br />

.480<br />

DIA. 18-PL.<br />

18-PL<br />

.450<br />

DIA. 260 PL.<br />

.090 DEG POINTS<br />

.045 HIGH<br />

SECTION "B" 2X SCALE<br />

.200<br />

DOME 308 PL.<br />

0.1350<br />

TILE INSTALLATION<br />

VIEW-B 4x SCALE<br />

1/4" x 1 1/2" LG.<br />

EXPANSION ANCHOR<br />

WWW.<strong>ADA</strong>TILE.COM<br />

MATERIAL LIST<br />

ITEM<br />

DESCRIPTION<br />

PART NO. QT'Y<br />

SCALE<br />

AS NOTED<br />

FULL SIZE<br />

TRADE<br />

DETECTABLE WARNING SURFACE<br />

MATERIAL<br />

PART NO.<br />

SEE MATERIAL LIST<br />

PROJECT<br />

SURFACE APPLIED DETECTABLE<br />

WARNING SURFACE SYSTEM<br />

24" x 36" SOUND ATTENUATING<br />

CURB RAMP TILE (INLINE DOME)<br />

PLANS AND DETAILS<br />

DRAWING NO. REV. NO.<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

PO Box 3<br />

N.Billerica, Ma. 01862<br />

28<br />

www.adatile.com • 800-372-0519


79°<br />

R.125<br />

4-PL.<br />

"B"<br />

R.1250<br />

4-PL.<br />

1.200<br />

2.3500<br />

VIEW-A 2x SCALE<br />

36.6500<br />

PART O.A.<br />

"B"<br />

.500<br />

4-SIDES<br />

.7500<br />

.480<br />

DIA. 18-PL.<br />

30°<br />

30°<br />

24.0000<br />

PART O.A.<br />

1.200<br />

9 -9 EQUAL SPACES<br />

2.3500<br />

PART O.A.<br />

0.4425<br />

1.2000<br />

21.6000<br />

9 - EQUAL SPACES<br />

1.2000<br />

0.1350<br />

WALL THICKNESS<br />

.1975<br />

.0625<br />

.200<br />

18-PL.<br />

.0625<br />

1/4" DIA. CTSK HOLES<br />

(TYP. 12 LOCATIONS)<br />

HALF SCALE<br />

18-PL<br />

.900<br />

DIA. 260 PL.<br />

1/4" x 1 1/2" LG.<br />

EXPANSION ANCHOR<br />

DOME 260 PL.<br />

.200<br />

1/4" DIA. CTSK HOLES<br />

(TYP. 12 LOCATIONS)<br />

.450<br />

DIA. 260 PL.<br />

SECTION "B" 2X SCALE<br />

.090 DEG POINTS<br />

.045 HIGH<br />

TILE INSTALLATION<br />

VIEW-B 4x SCALE<br />

WWW.<strong>ADA</strong>TILE.COM<br />

MATERIAL LIST<br />

ITEM DESCRIPTION<br />

PART NO. QT'Y<br />

SCALE<br />

AS NOTED<br />

FULL SIZE<br />

TRADE<br />

DETECTABLE WARNING SURFACE<br />

PART NO.<br />

SEE MATERIAL LIST<br />

MATERIAL<br />

PROJECT<br />

SURFACE APPLIED DETECTABLE<br />

WARNING SURFACE SYSTEM<br />

24" x 36" SOUND ATTENUATING<br />

CURB RAMP TILE (INLINE DOME)<br />

PLANS AND DETAILS<br />

DRAWING NO.<br />

REV. NO.<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

PO Box 3<br />

N.Billerica, Ma. 01862<br />

1<br />

2<br />

3<br />

4<br />

Surface Mount Composite Tactile<br />

24”x36” Tile<br />

2.35” Dome Spacing<br />

www.adatile.com • 800-372-0519 29


1<br />

3<br />

4<br />

79°<br />

2<br />

Surface Mount Composite Tactile<br />

24”x48” Tile<br />

1.67” Dome Spacing<br />

24.281<br />

PART O.A.<br />

1.297 1.670<br />

13 - 13 EQUAL SPACES<br />

0.443<br />

PART O.A.<br />

1.271<br />

21.709<br />

13 - EQUAL SPACES<br />

1.286<br />

R.1250<br />

4-PL.<br />

"B"<br />

0.1350<br />

WALL THICKNESS<br />

R.125<br />

4-PL.<br />

1/4" DIA. CTSK HOLES<br />

(TYP. 15 LOCATIONS)<br />

1.147<br />

1.670<br />

VIEW-A 4 x SCALE<br />

HALF SCALE<br />

1/4" DIA. CTSK HOLES<br />

(TYP. 15 LOCATIONS)<br />

.1975<br />

.0625<br />

.7500<br />

30°<br />

30°<br />

.200<br />

18-PL.<br />

.500<br />

"B" 4-SIDES<br />

49.060<br />

PART O.A.<br />

.900<br />

DIA. 260 PL.<br />

.0625<br />

.480<br />

DIA. 18-PL.<br />

18-PL<br />

.450<br />

DIA. 260 PL.<br />

.090 DEG POINTS<br />

.045 HIGH<br />

SECTION "B" 2X SCALE<br />

.200<br />

DOME 406 PL.<br />

0.1350<br />

TILE INSTALLATION<br />

VIEW-B 4x SCALE<br />

1/4" x 1 1/2" LG.<br />

EXPANSION ANCHOR<br />

WWW.<strong>ADA</strong>TILE.COM<br />

MATERIAL LIST<br />

ITEM<br />

DESCRIPTION<br />

PART NO. QT'Y<br />

SCALE<br />

AS NOTED<br />

FULL SIZE<br />

TRADE<br />

DETECTABLE WARNING SURFACE<br />

MATERIAL<br />

PART NO.<br />

SEE MATERIAL LIST<br />

PROJECT<br />

SURFACE APPLIED DETECTABLE<br />

WARNING SURFACE SYSTEM<br />

24" x 48" SOUND ATTENUATING<br />

CURB RAMP TILE (INLINE DOME)<br />

PLANS AND DETAILS<br />

DRAWING NO.<br />

REV. NO.<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

PO Box 3<br />

N.Billerica, Ma. 01862<br />

30<br />

www.adatile.com • 800-372-0519


79°<br />

1.200<br />

VIEW-A 2x SCALE<br />

.480<br />

DIA. 18-PL.<br />

30°<br />

0.4425<br />

PART O.A.<br />

0.1350<br />

WALL THICKNESS<br />

"B"<br />

R.1250<br />

4-PL.<br />

.7500<br />

.900<br />

DIA. 260 PL.<br />

1.200<br />

2.3500<br />

9 -9 EQUAL SPACES<br />

.1975<br />

.0625<br />

.200<br />

18-PL.<br />

.0625<br />

30°<br />

R.125<br />

4-PL.<br />

1/4" DIA. CTSK HOLES<br />

(TYP. 12 LOCATIONS)<br />

2.3500<br />

48.6500<br />

PART O.A.<br />

HALF SCALE<br />

"B"<br />

.500<br />

4-SIDES<br />

18-PL<br />

SECTION "B" 2X SCALE<br />

24.0000<br />

PART O.A.<br />

1.2000<br />

21.6000<br />

9 - EQUAL SPACES<br />

1.2000<br />

DOME 260 PL.<br />

.200<br />

1/4" DIA. CTSK HOLES<br />

(TYP. 12 LOCATIONS)<br />

.450<br />

DIA. 260 PL.<br />

.090 DEG POINTS<br />

.045 HIGH<br />

TILE INSTALLATION<br />

VIEW-B 4x SCALE<br />

1/4" x 1 1/2" LG.<br />

EXPANSION ANCHOR<br />

WWW.<strong>ADA</strong>TILE.COM<br />

MATERIAL LIST<br />

ITEM DESCRIPTION<br />

PART NO. QT'Y<br />

SCALE<br />

AS NOTED<br />

FULL SIZE<br />

TRADE<br />

DETECTABLE WARNING SURFACE<br />

PART NO.<br />

SEE MATERIAL LIST<br />

MATERIAL<br />

PROJECT<br />

SURFACE APPLIED DETECTABLE<br />

WARNING SURFACE SYSTEM<br />

24" x 48" SOUND ATTENUATING<br />

CURB RAMP TILE (INLINE DOME)<br />

PLANS AND DETAILS<br />

DRAWING NO. REV. NO.<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

1 Survey Circle<br />

N.Billerica, Ma. 01862<br />

1<br />

2<br />

3<br />

4<br />

Surface Mount Composite Tactile<br />

24”x48” Tile<br />

2.35” Dome Spacing<br />

www.adatile.com • 800-372-0519 31


79°<br />

1<br />

2<br />

3<br />

4<br />

Surface Mount Composite Tactile<br />

24”x60” Tile<br />

1.67” Dome Spacing<br />

24.281<br />

PART O.A.<br />

1.297<br />

1.670<br />

13 - 13 EQUAL SPACES<br />

0.443<br />

PART O.A.<br />

1.271<br />

21.709<br />

13 - EQUAL SPACES<br />

1.286<br />

R.1250<br />

4-PL.<br />

"B"<br />

0.1350<br />

WALL THICKNESS<br />

R.125<br />

4-PL.<br />

1/4" DIA. CTSK HOLES<br />

(TYP. 18 LOCATIONS)<br />

1.147<br />

1.670<br />

VIEW-A 4 x SCALE<br />

HALF SCALE<br />

1/4" DIA. CTSK HOLES<br />

(TYP. 18 LOCATIONS)<br />

.1975<br />

.0625<br />

.7500<br />

30°<br />

30°<br />

.200<br />

18-PL.<br />

.500<br />

"B" 4-SIDES<br />

60.750<br />

PART O.A.<br />

.900<br />

DIA. 260 PL.<br />

.0625<br />

.480<br />

DIA. 18-PL.<br />

18-PL<br />

.450<br />

DIA. 260 PL.<br />

.090 DEG POINTS<br />

.045 HIGH<br />

SECTION "B" 2X SCALE<br />

.200<br />

DOME 504 PL.<br />

0.1350<br />

TILE INSTALLATION<br />

VIEW-B 4x SCALE<br />

1/4" x 1 1/2" LG.<br />

EXPANSION ANCHOR<br />

WWW.<strong>ADA</strong>TILE.COM<br />

MATERIAL LIST<br />

ITEM<br />

DESCRIPTION<br />

PART NO.<br />

QT'Y<br />

SCALE<br />

AS NOTED<br />

FULL SIZE<br />

TRADE<br />

DETECTABLE WARNING SURFACE<br />

MATERIAL<br />

PART NO.<br />

SEE MATERIAL LIST<br />

PROJECT<br />

SURFACE APPLIED DETECTABLE<br />

WARNING SURFACE SYSTEM<br />

24" x 60" SOUND ATTENUATING<br />

CURB RAMP TILE (INLINE DOME)<br />

PLANS AND DETAILS<br />

DRAWING NO.<br />

REV. NO.<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

PO Box 3<br />

N.Billerica, Ma. 01862<br />

32<br />

www.adatile.com • 800-372-0519


79°<br />

R.125<br />

4-PL.<br />

60.6500<br />

PART O.A.<br />

.500<br />

4-SIDES<br />

18-PL<br />

.900<br />

DIA. 260 PL.<br />

.480<br />

DIA. 18-PL.<br />

DRAWING NO. REV. NO.<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

P.O. Box 3<br />

N.Billerica, Ma. 01862<br />

30°<br />

24.0000<br />

PART O.A.<br />

0.4425<br />

PART O.A.<br />

1.2000<br />

21.6000<br />

9 - EQUAL SPACES<br />

0.1350<br />

WALL THICKNESS<br />

.1975<br />

.0625<br />

.200<br />

18-PL.<br />

DOME 260 PL.<br />

.200<br />

1/4" DIA. CTSK HOLES<br />

(TYP. 12 LOCATIONS)<br />

"B" "B"<br />

R.1250<br />

4-PL.<br />

1.200<br />

2.3500<br />

VIEW-A 2x SCALE<br />

HALF SCALE<br />

.7500<br />

.450<br />

DIA. 260 PL.<br />

SECTION "B" 2X SCALE<br />

.090 DEG POINTS<br />

.045 HIGH<br />

TILE INSTALLATION<br />

VIEW-B 4x SCALE<br />

1/4" x 1 1/2" LG.<br />

EXPANSION ANCHOR<br />

MATERIAL LIST<br />

ITEM DESCRIPTION PART NO. QT'Y<br />

SCALE<br />

AS NOTED<br />

TRADE PART NO.<br />

DETECTABLE WARNING SURFACE<br />

SEE MATERIAL LIST<br />

MATERIAL<br />

PROJECT<br />

SURFACE APPLIED DETECTABLE<br />

WARNING SURFACE SYSTEM<br />

24" x 60" SOUND ATTENUATING<br />

CURB RAMP TILE (INLINE DOME)<br />

PLANS AND DETAILS<br />

1<br />

2<br />

3<br />

4<br />

Surface Mount Composite Tactile<br />

24”x60” Tile<br />

2.35” Dome Spacing<br />

1.200<br />

2.3500<br />

9 -9 EQUAL SPACES<br />

1.2000<br />

.0625<br />

30°<br />

1/4" DIA. CTSK HOLES<br />

(TYP. 12 LOCATIONS)<br />

WWW.<strong>ADA</strong>TILE.COM<br />

www.adatile.com • 800-372-0519 33


790<br />

1<br />

2<br />

3<br />

4<br />

Surface Mount Composite Tactile<br />

36”x48” Tile<br />

1.67” Dome Spacing<br />

36.000<br />

PART O.A.<br />

1.300<br />

1.670<br />

21 - 21 EQUAL SPACES<br />

0.443<br />

PART O.A.<br />

1.300<br />

33.399<br />

21 - EQUAL SPACES<br />

1.300<br />

R.1250<br />

4-PL.<br />

"B"<br />

0.1350<br />

WALL THICKNESS<br />

R.125<br />

4-PL.<br />

1/4" DIA. CTSK HOLES<br />

(TYP. 20 LOCATIONS)<br />

1.147 1.670<br />

VIEW-A 4 x SCALE<br />

HALF SCALE<br />

1/4" DIA. CTSK HOLES<br />

(TYP. 20 LOCATIONS)<br />

49.060<br />

PART O.A.<br />

"B"<br />

30°<br />

.1975<br />

.0625<br />

.7500<br />

300<br />

.200<br />

18-PL.<br />

.500<br />

4-SIDES<br />

.900<br />

DIA. 260 PL.<br />

.0625<br />

.450<br />

DIA. 18-PL.<br />

18-PL<br />

.450<br />

DIA. 260 PL.<br />

.090 DEG POINTS<br />

.045 HIGH<br />

SECTION "B" 4 X SCALE<br />

.200<br />

DOME 638 PL.<br />

0.1350<br />

TILE INSTALLATION<br />

VIEW-B 4x SCALE<br />

1/4" x 1 1/2" LG.<br />

EXPANSION ANCHOR<br />

WWW.<strong>ADA</strong>TILE.COM<br />

MATERIAL LIST<br />

ITEM<br />

DESCRIPTION<br />

PART NO. QT'Y<br />

SCALE<br />

AS NOTED<br />

FULL SIZE<br />

TRADE<br />

DETECTABLE WARNING SURFACE<br />

MATERIAL<br />

PART NO.<br />

SEE MATERIAL LIST<br />

PROJECT<br />

SURFACE APPLIED DETECTABLE<br />

WARNING SURFACE SYSTEM<br />

36" x 48" SOUND ATTENUATING<br />

CURB RAMP TILE (INLINE DOME)<br />

PLANS AND DETAILS<br />

DRAWING NO. REV. NO.<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

PO Box 3<br />

N.Billerica, Ma. 01862<br />

34<br />

www.adatile.com • 800-372-0519


79°<br />

"B"<br />

R.1250<br />

4-PL.<br />

1.147<br />

1.670<br />

VIEW-A 4 x SCALE<br />

60.750<br />

PART O.A.<br />

.900<br />

DIA. 260 PL.<br />

SECTION "B" 4 X SCALE<br />

36.000<br />

1.300<br />

1.670<br />

21 - 21 EQUAL SPACES<br />

0.443<br />

PART O.A.<br />

1.300<br />

33.399<br />

21 - EQUAL SPACES<br />

0.1350<br />

WALL THICKNESS<br />

.0625<br />

.500<br />

4-SIDES<br />

30°<br />

.1975<br />

.0625<br />

.200<br />

18-PL.<br />

30°<br />

R.125<br />

4-PL.<br />

1/4" DIA. CTSK HOLES<br />

(TYP. 24 LOCATIONS)<br />

HALF SCALE<br />

1/4" DIA. CTSK HOLES<br />

(TYP. 24 LOCATIONS)<br />

"B"<br />

.7500<br />

18-PL<br />

.480<br />

DIA. 18-PL.<br />

PART O.A.<br />

1.300<br />

DOME 792 PL.<br />

.200<br />

0.1350<br />

.450<br />

DIA. 260 PL.<br />

.090 DEG POINTS<br />

.045 HIGH<br />

TILE INSTALLATION<br />

VIEW-B 4x SCALE<br />

1/4" x 1 1/2" LG.<br />

EXPANSION ANCHOR<br />

WWW.<strong>ADA</strong>TILE.COM<br />

MATERIAL LIST<br />

ITEM<br />

DESCRIPTION<br />

PART NO. QT'Y<br />

SCALE<br />

AS NOTED<br />

FULL SIZE<br />

TRADE<br />

DETECTABLE WARNING SURFACE<br />

PART NO.<br />

SEE MATERIAL LIST<br />

MATERIAL<br />

PROJECT<br />

SURFACE APPLIED DETECTABLE<br />

WARNING SURFACE SYSTEM<br />

36" x 60" SOUND ATTENUATING<br />

CURB RAMP TILE (INLINE DOME)<br />

PLANS AND DETAILS<br />

DRAWING NO. REV. NO.<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

PO Box 3<br />

N.Billerica, Ma. 01862<br />

1<br />

2<br />

3<br />

4<br />

Surface Mount Composite Tactile<br />

36”x60” Tile<br />

1.67” Dome Spacing<br />

www.adatile.com • 800-372-0519 35


Cast-In-Place<br />

Tactile<br />

36


Proudly Made in<br />

the U.S.A.<br />

37


Cast-In-Place Tactile<br />

Installation Procedure<br />

Be sure to read and understand all of these instructions before you begin.<br />

A. The physical characteristics of the concrete shall be as specified in the<br />

contract documents while maintaining a slump range of 4-7 to permit the solid<br />

placement of the Tactile Unit in the wet cement.<br />

B. The concrete shall be poured and finished level, true and smooth to the required<br />

dimensions prior to the placement of the Tactile Unit.<br />

C. Place the Tactile Unit 6-8 inches from the curb line. Working in a grid pattern,<br />

tamp the Tactile Unit into the wet concrete using a rubber mallet<br />

and a piece of wood. Continue this process until all of the air has been<br />

released, and the Tactile Unit surface is flush with the surrounding area.<br />

IMPORTANT: Avoid striking the surface of the Tactile Unit directly.<br />

D. Following the placement, the Tactile Unit elevation should be checked to the adjacent<br />

surface with a straight edge. The Tactile Unit elevation should be consistent<br />

with the contract drawings and specifications. Any required<br />

adjustments must be made prior to the time when the concrete<br />

begins to set.<br />

E. Important Notice to Installer: To allow for expansion<br />

and contraction, after tile is installed, use a 1/4” finish edge trowel<br />

around entire perimeter. On a continous run, be sure to space each<br />

unit 1/8” apart.<br />

F. When you are confident that the Tactile Unit is in place, and<br />

no further adjustments are needed, place a cinder block on both<br />

ends to hold the Tactile Unit in place while the concrete sets.<br />

G. During and after the Tactile Unit installation, as well as the<br />

concrete curing stage, no walking or external forces can be<br />

placed on the Tactile Unit. The area must be protected from<br />

pedestrian traffic until concrete is cured. The Tactile Warning<br />

Surface will be ready for pedestrian traffic within 2-4 hours.<br />

H. Be sure to remove plastic protective covering from the face of<br />

the Tactile Unit once the concrete is cured.<br />

View additional photos, drawings and specifications on our website:<br />

www.adatile.com. Call (800) 372-0519 with any questions.<br />

PRODUCT SIZES<br />

2’x3’ 2’x4’ 2’x5’<br />

3’x4’ 3’x5’<br />

APPLICATION<br />

Fresh Pour<br />

Concrete<br />

Ramps<br />

38<br />

www.adatile.com • 800-372-0519


DOME GEOMETRY<br />

In accordance with <strong>ADA</strong> Regulations for Detectable Warning on Curb Ramps: Raised truncated domes with a diameter of nominal<br />

0.9”, a height of nominal 0.2”, and a center-to-center spacing of 1.67” minimum, and 2.35” maximum.<br />

PANEL DIMENSIONS<br />

Tactile Units are available in 2’x3’ , 2’x4’ , 2’x5’ , 3’x4’ and 3’x5’ sizes. Tactile Units may also be custom configured to accommodate<br />

specific project requirements. Tactile Units measure 0.25” nominal thickness and feature embedment ribs at 3” on center.<br />

MATERIAL<br />

A homogenous glass and carbon reinforced composite which is colorfast and UV stable. Truncated domes are fiberglass reinforced<br />

for enhanced durability. The color of the Tactile Unit is uniform throughout and does not rely on any type of paint coating to<br />

achieve color stability. Standard colors include: Federal Yellow, Brick<br />

Red, Clay Red, Safety Red, Blue, Dark Gray and Black.<br />

INSTALLATION<br />

Tactile Units are to be used on new curb ramp locations. The Tactile<br />

Units can be pre-filled with concrete and set in place or pressed into<br />

place in the freshly poured concrete.<br />

Cast-In-Place Tactile<br />

Inline Dome Pattern<br />

PHYSICAL CHARACTERISTICS<br />

Compressive Strength 28,900 psi ASTM D 695<br />

Flexural Strength 29,300 psi ASTM D 790<br />

Water Absorption .07% ASTM D 570<br />

Slip Resistance 1.18 Dry, 1.05 Wet ASTM C 1028<br />

Flame Spread Index 20 ASTM E 84<br />

Salt Spray No Change (200 hours) ASTM B 117<br />

Chemical Stain Testing No Deterioration ASTM 1308<br />

Abrasion Resistance 549 ASTM C 501<br />

Accelerated Weathering Delta E


1<br />

2<br />

3<br />

4<br />

Cast-In-Place Tactile<br />

24”x36” Tile<br />

1.67” Dome Spacing<br />

24.000<br />

PART O.A.<br />

1.670 1.145<br />

13 - 13 EQUAL SPACES<br />

DETAIL "B"<br />

1.145<br />

21.710 1.145<br />

13 - EQUAL SPACES<br />

DETAIL "A"<br />

DETAIL "C"<br />

1.434<br />

1.670<br />

27 - 27 EQUAL SPACES<br />

DETAIL "A"<br />

36.000<br />

PART O.A.<br />

TOP OF PANEL<br />

1.375<br />

.250<br />

0.750<br />

EQUAL SPACES OF .750<br />

.1875<br />

DETAIL "B"<br />

6.000<br />

3.000<br />

TYP.<br />

0.188<br />

+2° A/S DRAFT<br />

1.160<br />

.060<br />

.200<br />

.450<br />

DIA.<br />

.900<br />

DIA.<br />

FLANGE @ 3" C/C (SEE PLAN<br />

FOR ORIENTATION)<br />

.1875<br />

0.625" DIA. HOLE<br />

EMBEDMENT FLANGES<br />

AS SHOWN IN PLAN<br />

.0600<br />

DETAIL "C"<br />

0.090 0.090<br />

0.045<br />

90°<br />

0.625" DIA. HOLE<br />

EMBEDMENT FLANGES<br />

BOTTOM OF PANEL<br />

INTERNAL EMBEDMENT<br />

FLANGE @ 3" C/C<br />

36.000<br />

PART O.A.<br />

90°<br />

0.045<br />

24.000<br />

PART O.A.<br />

WWW.<strong>ADA</strong>TILE.COM<br />

MATERIAL LIST<br />

ITEM<br />

DESCRIPTION<br />

PART NO.<br />

QT'Y<br />

SCALE<br />

AS NOTED<br />

FULL SIZE<br />

TRADE<br />

DETECTABLE WARNING SURFACE<br />

MATERIAL<br />

PART NO.<br />

SEE MATERIAL LIST<br />

PROJECT<br />

EMBEDMENT PANEL DETECTABLE<br />

WARNING SURFACE SYSTEM<br />

24" x 36" SOUND ATTENUATING<br />

CURB RAMP TILE (INLINE DOME)<br />

PLANS AND DETAILS<br />

DRAWING NO.<br />

REV. NO.<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

P.O. Box 3<br />

N.Billerica, Ma. 01862<br />

40<br />

www.adatile.com • 800-372-0519


Cast-In-Place Tactile<br />

24”x36” Tile<br />

2.35” Dome Spacing<br />

DETAIL "A"<br />

36.000<br />

PART O.A.<br />

TOP OF PANEL<br />

24.000<br />

PART O.A.<br />

1.200 21.600<br />

9 - EQUAL SPACES<br />

1.200<br />

24.000<br />

PART O.A.<br />

1.200<br />

2.3500<br />

DETAIL "A"<br />

INTERNAL EMBEDMENT<br />

FLANGE @ 3" C/C (SEE PLAN<br />

FOR ORIENTATION)<br />

.450<br />

36.000<br />

PART O.A.<br />

INTERNAL EMBEDMENT<br />

FLANGE @ 3" C/C<br />

BOTTOM OF PANEL<br />

0.625" DIA. HOLE<br />

EMBEDMENT FLANGES<br />

MATERIAL LIST<br />

ITEM DESCRIPTION<br />

PART NO.<br />

SCALE<br />

AS NOTED<br />

FULL SIZE<br />

TRADE<br />

DETECTABLE WARNING SURFACE<br />

PART NO.<br />

SEE MATERIAL LIST<br />

MATERIAL<br />

PROJECT<br />

EMBEDMENT PANEL DETECTABLE<br />

WARNING SURFACE SYSTEM<br />

24" x 36" SOUND ATTENUATING<br />

CURB RAMP TILE (INLINE DOME)<br />

PLANS AND DETAILS<br />

DRAWING NO.<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

P.O. Box 3<br />

N.Billerica, Ma. 01862<br />

QT'Y<br />

REV. NO.<br />

1<br />

2<br />

3<br />

4<br />

2.3500<br />

1.200<br />

9 -9 EQUAL SPACES<br />

.060<br />

0.750<br />

EQUAL SPACES OF .750<br />

.1875<br />

1.160<br />

TYP.<br />

0.188<br />

+2° A/S DRAFT<br />

3.000<br />

6.000<br />

.1875<br />

0.625" DIA. HOLE<br />

EMBEDMENT FLANGES<br />

AS SHOWN IN PLAN<br />

1.375<br />

.250<br />

.0600<br />

DIA.<br />

.900<br />

DIA.<br />

.09000<br />

DIA.<br />

DETAIL "C"<br />

.200<br />

DETAIL "B"<br />

90°<br />

90°<br />

.0450<br />

.0450<br />

DETAIL "B"<br />

DETAIL "C"<br />

.0900<br />

DIA.<br />

WWW.<strong>ADA</strong>TILE.COM<br />

www.adatile.com • 800-372-0519<br />

41


1<br />

2<br />

3<br />

4<br />

Cast-In-Place Tactile<br />

24”x48”<br />

1.67” Dome Spacing<br />

24.000<br />

PART O.A.<br />

1.670<br />

13 - 13 EQUAL SPACES<br />

1.145<br />

DETAIL "B"<br />

1.145<br />

21.710<br />

13 - EQUAL SPACES<br />

1.145<br />

DETAIL "A"<br />

1.434<br />

DETAIL "C"<br />

1.670<br />

27 - 27 EQUAL SPACES<br />

DETAIL "A"<br />

48.000<br />

PART O.A.<br />

TOP OF PANEL<br />

Sect. A-A<br />

1.375<br />

.250<br />

EQUAL SPACES OF .750<br />

0.750<br />

.1875<br />

DETAIL "B"<br />

6.000<br />

3.000<br />

0.188<br />

+2° A/S DRAFT<br />

1.160<br />

TYP.<br />

.060<br />

.200<br />

.450<br />

DIA.<br />

.900<br />

DIA.<br />

FLANGE @ 3" C/C (SEE PLAN<br />

FOR ORIENTATION)<br />

.1875<br />

0.625" DIA. HOLE<br />

EMBEDMENT FLANGES<br />

AS SHOWN IN PLAN<br />

.0600<br />

DETAIL "C"<br />

0.090 0.090<br />

0.045<br />

90°<br />

0.625" DIA. HOLE<br />

EMBEDMENT FLANGES<br />

BOTTOM OF PANEL<br />

INTERNAL EMBEDMENT<br />

FLANGE @ 3" C/C<br />

48.000<br />

PART O.A.<br />

90°<br />

0.045<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

P.O. Box 3<br />

N.Billerica, Ma. 01862<br />

DRAWING NO. REV. NO.<br />

PLANS AND DETAILS<br />

24" x 48" SOUND ATTENUATING<br />

CURB RAMP TILE (INLINE DOME)<br />

EMBEDMENT PANEL DETECTABLE<br />

WARNING SURFACE SYSTEM<br />

PROJECT<br />

MATERIAL<br />

TRADE<br />

DETECTABLE WARNING SURFACE<br />

SEE MATERIAL LIST<br />

PART NO.<br />

SCALE<br />

AS NOTED<br />

FULL SIZE<br />

ITEM<br />

DESCRIPTION<br />

PART NO. QT'Y<br />

MATERIAL LIST<br />

WWW.<strong>ADA</strong>TILE.COM<br />

24.000<br />

PART O.A.<br />

42<br />

www.adatile.com • 800-372-0519


Cast-In-Place Tactile<br />

24”x48” Tile<br />

2.35” Dome Spacing<br />

DETAIL "A"<br />

48.000<br />

PART O.A.<br />

TOP OF PANEL<br />

48.000<br />

PART O.A.<br />

INTERNAL EMBEDMENT<br />

FLANGE @ 3" C/C<br />

BOTTOM OF PANEL<br />

0.625" DIA. HOLE<br />

EMBEDMENT FLANGES<br />

MATERIAL LIST<br />

ITEM DESCRIPTION<br />

PART NO. QT'Y<br />

SCALE<br />

AS NOTED<br />

FULL SIZE<br />

TRADE<br />

DETECTABLE WARNING SURFACE<br />

PART NO.<br />

SEE MATERIAL LIST<br />

MATERIAL<br />

PROJECT<br />

EMBEDMENT PANEL DETECTABLE<br />

WARNING SURFACE SYSTEM<br />

24" x 48" SOUND ATTENUATING<br />

CURB RAMP TILE (INLINE DOME)<br />

PLANS AND DETAILS<br />

DRAWING NO.<br />

REV. NO.<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

P.O. Box 3<br />

N.Billerica, Ma. 01862<br />

1<br />

2<br />

3<br />

4<br />

24.000<br />

PART O.A.<br />

1.200 21.600<br />

9 - EQUAL SPACES<br />

1.200<br />

24.000<br />

PART O.A.<br />

1.200<br />

2.3500<br />

DETAIL "A"<br />

INTERNAL EMBEDMENT<br />

FLANGE @ 3" C/C (SEE PLAN<br />

FOR ORIENTATION)<br />

.450<br />

1.160<br />

TYP.<br />

0.188<br />

+2° A/S DRAFT<br />

6.000<br />

DETAIL "B"<br />

2.3500<br />

9 -9 EQUAL SPACES<br />

1.200<br />

1.375<br />

.060<br />

0.750<br />

EQUAL SPACES OF .750<br />

.1875<br />

DIA.<br />

3.000<br />

.250<br />

.0600<br />

DIA.<br />

.900<br />

90°<br />

90°<br />

.1875<br />

0.625" DIA. HOLE<br />

EMBEDMENT FLANGES<br />

AS SHOWN IN PLAN<br />

.200<br />

.0450<br />

.0450<br />

DETAIL "B"<br />

DETAIL "C"<br />

.0900<br />

DIA.<br />

.09000<br />

DIA.<br />

DETAIL "C"<br />

WWW.<strong>ADA</strong>TILE.COM<br />

www.adatile.com • 800-372-0519<br />

43


1<br />

2<br />

3<br />

4<br />

Cast-In-Place Tactile<br />

24”x60” Tile<br />

1.67” Dome Spacing<br />

24.000<br />

PART O.A.<br />

1.670 1.145<br />

13 - 13 EQUAL SPACES<br />

DETAIL "B"<br />

1.145<br />

21.710 1.145<br />

13 - EQUAL SPACES<br />

DETAIL "A"<br />

1.434<br />

DETAIL "C"<br />

27 - 27 EQUAL SPACES<br />

1.670<br />

DETAIL "A"<br />

1.375<br />

.250<br />

TOP OF PANEL<br />

60.000<br />

PART O.A.<br />

0.750<br />

EQUAL SPACES OF .750<br />

.1875<br />

DETAIL "B"<br />

6.000<br />

3.000<br />

0.188<br />

+2° A/S DRAFT<br />

1.160<br />

TYP.<br />

.060<br />

.200<br />

.450<br />

DIA.<br />

.900<br />

DIA.<br />

FLANGE @ 3" C/C (SEE PLAN<br />

FOR ORIENTATION)<br />

.1875<br />

0.625" DIA. HOLE<br />

EMBEDMENT FLANGES<br />

AS SHOWN IN PLAN<br />

.0600<br />

DETAIL "C"<br />

0.090 0.090<br />

0.045<br />

90°<br />

90°<br />

0.045<br />

0.625" DIA. HOLE<br />

EMBEDMENT FLANGES<br />

BOTTOM OF PANEL<br />

INTERNAL EMBEDMENT<br />

FLANGE @ 3" C/C<br />

60.000<br />

PART O.A.<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

P.O. Box 3<br />

N.Billerica, Ma. 01862<br />

DRAWING NO. REV. NO.<br />

24" x 60" SOUND ATTENUATING<br />

CURB RAMP TILE (INLINE DOME)<br />

PLANS AND DETAILS<br />

EMBEDMENT PANEL DETECTABLE<br />

WARNING SURFACE SYSTEM<br />

PROJECT<br />

MATERIAL<br />

TRADE<br />

DETECTABLE WARNING SURFACE<br />

SEE MATERIAL LIST<br />

PART NO.<br />

AS NOTED<br />

FULL SIZE<br />

SCALE<br />

ITEM<br />

DESCRIPTION<br />

PART NO.<br />

QT'Y<br />

MATERIAL LIST<br />

WWW.<strong>ADA</strong>TILE.COM<br />

24.000<br />

PART O.A.<br />

44<br />

www.adatile.com • 800-372-0519


Cast-In-Place Tactile<br />

24”x60” Tile<br />

2.35” Dome Spacing<br />

1.200 2.3500<br />

DETAIL "A"<br />

0.750<br />

EQUAL SPACES OF .750<br />

.1875<br />

.450<br />

DIA.<br />

6.000<br />

DETAIL "B"<br />

.900<br />

DIA.<br />

90°<br />

90°<br />

.1875<br />

MATERIAL LIST<br />

ITEM DESCRIPTION<br />

PART NO. QT'Y<br />

SCALE<br />

AS NOTED<br />

FULL SIZE<br />

TRADE<br />

DETECTABLE WARNING SURFACE<br />

PART NO.<br />

SEE MATERIAL LIST<br />

MATERIAL<br />

PROJECT<br />

EMBEDMENT PANEL DETECTABLE<br />

WARNING SURFACE SYSTEM<br />

24" x 60" SOUND ATTENUATING<br />

CURB RAMP TILE (INLINE DOME)<br />

PLANS AND DETAILS<br />

DRAWING NO. REV. NO.<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

P.O. Box 3<br />

N.Billerica, Ma. 01862<br />

1<br />

2<br />

3<br />

4<br />

2.3500 1.200<br />

9 -9 EQUAL SPACES<br />

1.375<br />

.250<br />

.200<br />

.0450<br />

.0600<br />

.0450<br />

DETAIL "A"<br />

DETAIL "B"<br />

DETAIL "C"<br />

60.000<br />

PART O.A.<br />

INTERNAL EMBEDMENT<br />

FLANGE @ 3" C/C (SEE PLAN<br />

FOR ORIENTATION)<br />

60.000<br />

PART O.A.<br />

.0900<br />

DIA.<br />

.09000<br />

DIA.<br />

DETAIL "C"<br />

0.625" DIA. HOLE<br />

EMBEDMENT FLANGES<br />

AS SHOWN IN PLAN<br />

24.000<br />

PART O.A.<br />

1.200<br />

21.600<br />

1.200<br />

9 - EQUAL SPACES<br />

24.000<br />

PART O.A.<br />

TOP OF PANEL<br />

1.160<br />

TYP.<br />

0.188<br />

+2° A/S DRAFT<br />

3.000<br />

INTERNAL EMBEDMENT<br />

FLANGE @ 3" C/C<br />

BOTTOM OF PANEL<br />

0.625" DIA. HOLE<br />

EMBEDMENT FLANGES<br />

WWW.<strong>ADA</strong>TILE.COM<br />

.060<br />

www.adatile.com • 800-372-0519<br />

45


1<br />

2<br />

3<br />

4<br />

Cast-In-Place Tactile<br />

36”x48” Tile<br />

1.67” Dome Spacing<br />

1.670<br />

20 -20 EQUAL SPACES<br />

1.300<br />

0.775<br />

DETAIL "B"<br />

1.300<br />

36.000<br />

PART O.A.<br />

33.400<br />

20 - EQUAL SPACES<br />

1.300<br />

DETAIL "A"<br />

DETAIL "B"<br />

DETAIL "A"<br />

6.000<br />

3.000<br />

.1875<br />

.1875<br />

0.625" DIA. HOLE<br />

EMBEDMENT FLANGES<br />

AS SHOWN IN PLAN<br />

0.188<br />

+2° A/S DRAFT<br />

1.160<br />

TYP.<br />

1.375<br />

.060<br />

.250<br />

.200<br />

.0600<br />

0.750<br />

EQUAL SPACES OF .750<br />

.450<br />

DIA.<br />

.900<br />

DIA.<br />

35 -35 EQUAL SPACES<br />

1.670<br />

FLANGE @ 3" C/C (SEE PLAN<br />

FOR ORIENTATION)<br />

DETAIL "C"<br />

Sect. A-A<br />

0.090 0.090<br />

DETAIL "C"<br />

0.625" DIA. HOLE<br />

EMBEDMENT FLANGES<br />

90°<br />

TOP OF PANEL BOTTOM OF PANEL<br />

90°<br />

0.045<br />

0.045<br />

"A" "A"<br />

INTERNAL EMBEDMENT<br />

FLANGE @ 3" C/C<br />

48.000 48.000<br />

PART O.A.<br />

PART O.A.<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

P.O. Box 3<br />

N.Billerica, Ma. 01862<br />

DRAWING NO. REV. NO.<br />

36" x 48" SOUND ATTENUATING<br />

CURB RAMP TILE (INLINE DOME)<br />

PLANS AND DETAILS<br />

EMBEDMENT PANEL DETECTABLE<br />

WARNING SURFACE SYSTEM<br />

PROJECT<br />

MATERIAL<br />

TRADE<br />

DETECTABLE WARNING SURFACE<br />

SEE MATERIAL LIST<br />

PART NO.<br />

AS NOTED<br />

FULL SIZE<br />

SCALE<br />

ITEM<br />

DESCRIPTION<br />

PART NO.<br />

QT'Y<br />

MATERIAL LIST<br />

WWW.<strong>ADA</strong>TILE.COM<br />

36.000<br />

PART O.A.<br />

46<br />

www.adatile.com • 800-372-0519


Cast-In-Place Tactile<br />

36”x60” Tile<br />

1.67” Dome Spacing<br />

DETAIL "A"<br />

DETAIL "B"<br />

60.000<br />

PART O.A.<br />

60.000<br />

PART O.A.<br />

DETAIL "C"<br />

DETAIL "C"<br />

DETAIL "A"<br />

MATERIAL LIST<br />

ITEM DESCRIPTION<br />

PART NO.<br />

QT'Y<br />

SCALE<br />

AS NOTED<br />

FULL SIZE<br />

TRADE<br />

DETECTABLE WARNING SURFACE<br />

PART NO.<br />

SEE MATERIAL LIST<br />

MATERIAL<br />

PROJECT<br />

EMBEDMENT PANEL DETECTABLE<br />

WARNING SURFACE SYSTEM<br />

36" x 60" SOUND ATTENUATING<br />

CURB RAMP TILE (INLINE DOME)<br />

PLANS AND DETAILS<br />

DRAWING NO. REV. NO.<br />

<strong>ADA</strong> SOLUTIONS, INC.<br />

P.O. Box 3<br />

N.Billerica, Ma. 01862<br />

1<br />

2<br />

3<br />

4<br />

36.000<br />

PART O.A.<br />

33.400<br />

20 - EQUAL SPACES<br />

36.000<br />

PART O.A.<br />

INTERNAL EMBEDMENT<br />

FLANGE @ 3" C/C<br />

TOP OF PANEL BOTTOM OF PANEL<br />

0.625" DIA. HOLE<br />

EMBEDMENT FLANGES<br />

0.090 0.090<br />

1.300<br />

1.300<br />

0.045<br />

0.045<br />

0.775<br />

"A" "A"<br />

Sect. A-A<br />

90°<br />

1.670<br />

35 -35 EQUAL SPACES<br />

FLANGE @ 3" C/C (SEE PLAN<br />

FOR ORIENTATION)<br />

0.750<br />

EQUAL SPACES OF .750<br />

.450<br />

DIA.<br />

DIA.<br />

.900<br />

1.160<br />

TYP.<br />

6.000<br />

DETAIL "B"<br />

90°<br />

1.670<br />

20 -20 EQUAL SPACES<br />

1.300<br />

1.375<br />

.060<br />

.250<br />

.200<br />

.0600<br />

35.485<br />

.1875<br />

0.188<br />

+2° A/S DRAFT<br />

3.000<br />

.1875<br />

0.625" DIA. HOLE<br />

EMBEDMENT FLANGES<br />

AS SHOWN IN PLAN<br />

WWW.<strong>ADA</strong>TILE.COM<br />

www.adatile.com • 800-372-0519<br />

47


About the Law<br />

Summary<br />

To view the entire report published by the Access Board go to<br />

REVISED DRAFT GUIDELINES:<br />

http://www.access-board.gov/rowdraft.htm<br />

Accessible Public Rights-Of-Way (11/23/05)<br />

R304 Detectable Warning Surfaces<br />

R304.1 General. Detectable warnings shall consist of a surface of truncated domes aligned in a<br />

square or radial grid pattern and shall comply with R304.<br />

R304.1.1 Dome Size. Truncated domes in a detectable warning surface shall have a base<br />

diameter of 23 mm (0.9 in) minimum to 36 mm (1.4 in) maximum, a top diameter of 50<br />

percent of the base diameter minimum to 65 precent of the base diameter maximum, and a<br />

height of 5 mm (0.2 in).<br />

R304.1.2 Dome Spacing. Truncated domes in a detectable warning surface shall have a<br />

center-to-center spacing of 41 mm (1.6 in) minimum and 61 mm (2.4 in) maximum, and<br />

a base-to-base spacing of 17 mm (.65 in) minimum, measured between the most adjacent<br />

domes.<br />

R304.1.3 Contrast. Detectable warning surfaces shall contrast visually with adjacent gutter,<br />

street or highway, or walkway surface, either light-on-dark, or dark-on-light.<br />

R304.1.4 Size. Detectable warning surfaces shall extend 610 mm (24 in) minimum in the<br />

direction of travel and the full width of the curb ramp (exclusive of flares), the landing, or the<br />

blended transition.<br />

R304.2 Location and Alignment<br />

R304.2.1 Perpendicular Curb Ramps. Where both ends of the bottom grade break<br />

complying with R303.3.4 are 1.5 m (5.0 ft) or less from the back of the curb, the detectable<br />

warning shall be located on the ramp surface at the bottom grade break. Where either end of<br />

the bottom grade break is more than 1.5 m (5.0 ft) from the back of the curb, the<br />

detectable warning shall be located on the lower landing.<br />

R304.2.2 Landings and Blended Transitions. The detectable warning shall be located on<br />

the landing or blended transition at the back of the curb.<br />

R304.2.3 Alignment. The rows of truncated domes in a detectable warning surface shall be<br />

aligned to be perpendicular or radial to the grade break between the ramp, landing, or blended<br />

transition and the street.<br />

48<br />

www.adatile.com • 800-372-0519


THE ONLY COMPLETE DETECTABLE WARNING AND<br />

WAYFINDING SOLUTION FOR THE VISUALLY IMPAIRED<br />

49


www.adatile.com • 800-372-0519 8/11