ADA Solutions, Inc. - Product Brochure - Reed Construction Data
ADA Solutions, Inc. - Product Brochure - Reed Construction Data
ADA Solutions, Inc. - Product Brochure - Reed Construction Data
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
U.S. Patent<br />
No. 7,779,581<br />
Proudly Made in<br />
the U.S.A.<br />
www.adatile.com • 800-372-0519
24.000<br />
21.600 9 - EQUAL SPACES<br />
1.200<br />
14.400<br />
PART O.A.<br />
36.000<br />
27.429<br />
PART O.A.<br />
B<br />
B<br />
1.200<br />
VIEW-D<br />
1.250<br />
TOP VIEW<br />
34.286<br />
15 - EQUAL SPACES<br />
SIDE VIEW<br />
SECTION B-B<br />
VIEW -B<br />
.090 DEG. POINTS<br />
.045 HIGH TYP.<br />
.450<br />
DIA. TOP OF DOMES<br />
0.245<br />
0.200<br />
.900<br />
DIA. TYP.<br />
60.000°<br />
1.375<br />
DIA.(6)<br />
1.125<br />
DIA.(6)<br />
CAP COVER<br />
0.6250<br />
(6)<br />
0.722<br />
0.562<br />
0.062<br />
0.875<br />
(6)<br />
0.500<br />
0.250<br />
0.967<br />
P.O. Box 3 • North Billerica, MA 01862<br />
R 0.250<br />
TYP.<br />
VIEW -B 3 x SIZE<br />
HEX HEAD BOLTS & WASHER 6-PL.<br />
Copyright © 2008-2011 <strong>ADA</strong> <strong>Solutions</strong>, <strong>Inc</strong>. All rights reserved.
<strong>ADA</strong> <strong>Product</strong>s Feature:<br />
Composite Detectable Warning Surfaces<br />
for Pedestrian Crossings<br />
Cast-In-Place Replaceable<br />
Radius Replaceable (WET-SET)<br />
Radius Surface Mount<br />
Surface Mount (Retrofit)<br />
Cast–In–Place (WET-SET)<br />
Cost Effective, Readily Available, and Easy to Install<br />
<strong>ADA</strong>AG/PROW/CA Title 24 Compliant<br />
– Pleasing architectural quality appearance and high performance product with geometry strictly<br />
compliant with all applicable codes.<br />
– Approved for use by all major municipalities, DPW’s and state DOT’s.<br />
Superior Wear Resistance<br />
– Wear resistance properties far superior to that achieved with concrete based materials of any type.<br />
– <strong>ADA</strong>’s product will conform to irregular underlying substrates.<br />
– Eliminates hairline cracking observed in epoxy based and VPC (Vitrified Polymer Composite)<br />
based materials.<br />
Maintenance<br />
– Virtually impervious to absorption (key indicator of durability) when compared to<br />
concrete, epoxy, or VPC materials. Not affected by chemical exposure.<br />
– Performs well when subjected to snow removal operations.<br />
– Easy to clean and replace when necessary.<br />
Homogenous Materials allow for Superior Color Stability<br />
– Pigment is uniformly distributed throughout the thickness of our products.<br />
– Long term color stability without the need for secondary coatings.<br />
<strong>Product</strong> Availability<br />
– Immediate delivery<br />
– National distribution<br />
Proudly Made in the U.S.A.<br />
We offer unmatched selection, service, delivery and price, with a strong focus on customer satisfaction.<br />
<strong>ADA</strong> <strong>Solutions</strong>, <strong>Inc</strong>. is leading the way in the detectable warning marketplace. Use us once and you’ll<br />
see why so many companies across the country choose <strong>ADA</strong> <strong>Solutions</strong>, <strong>Inc</strong>.<br />
In stock colors<br />
Yellow<br />
Brick<br />
Red<br />
Black<br />
Dark<br />
Gray<br />
Clay<br />
Red<br />
1. Federal Yellow #33538 (lusterless)<br />
2. Brick Red #20109 (lusterless)<br />
3. Black #37038 (lusterless)<br />
4. Dark Gray #36118 (lusterless)<br />
5. Clay Red #22144 (lusterless)<br />
6. Safety Red #31350 (lusterless)<br />
43.8<br />
7.3<br />
2.5<br />
2.5<br />
7.8<br />
8.6<br />
www.adatile.com • 800-372-0519<br />
1
REPLACEABLE<br />
RADIUS<br />
REPLACEABLE<br />
Varies<br />
RADIUS<br />
SURFACE<br />
MOUNT<br />
Varies<br />
2
USE OF CHEM LINK M-1 ® ADHESIVE/SEALANT TO INSTALL<br />
<strong>ADA</strong> TACTILE WARNING SURFACE & WAYFINDING PANELS<br />
<strong>ADA</strong> <strong>Solutions</strong>, <strong>Inc</strong>. offers the most complete and cost effective<br />
composite tactile warning surface (TWS) and wayfinding product line in<br />
the industry. <strong>ADA</strong> the North American market share leader. <strong>ADA</strong> offers<br />
Surface Applied (SA) TWS Panels, Cast-In-Place (CIP) TWS Units, and<br />
Replaceable (REP) TWS Units to meet your project requirements. <strong>ADA</strong>’s<br />
TWS products offer outstanding long-term performance, are slip<br />
resistant, offer superior long-term color stability, and can be installed<br />
with a minimum of effort under a wide variety of conditions. <strong>ADA</strong>’s<br />
products comply with <strong>ADA</strong>AG, PROW, and CATitle 24<br />
requirements. <strong>ADA</strong> recommends the use of Hydroment ®<br />
Ultra-Set ® Advanced and Durabond D-818 urethane<br />
adhesives for installation of its tactile warning surface<br />
and wayfinding products.<br />
TYPICAL PHYSICAL PROPERTIES<br />
V.O.C. Compliant<br />
Less than 20 grams/liter<br />
Color<br />
White, Gray<br />
Weight<br />
11.7 lbs per gallon<br />
Hardness<br />
45+3 Shore A Type<br />
Flash Point<br />
N/A<br />
Sheer Strength<br />
400 PSI<br />
Elongation 400-550%<br />
Low Temp Flex<br />
-10° F<br />
Cure Time<br />
24 hours<br />
Service Temperature<br />
Normal Use<br />
-40° F to 200° F<br />
Continuous Immersion<br />
120° F<br />
• LEED 2.2 for New <strong>Construction</strong> and Major<br />
Renovations: Low Emitting Materials (Section 4.1)<br />
1 Point<br />
• NAHB Model Green Home Building Guidelines:<br />
5 Global Impact Points<br />
• VOC Content at 240° F: less than 20 grams/liter<br />
(including water), ASTM D2369, EPA Method 24<br />
ADH5GAL<br />
3
Cast-In-Place (wet-set)<br />
Replaceable Tactile<br />
4
Proudly Made in<br />
the U.S.A.<br />
U.S. Patent<br />
No. 7,779,581<br />
5
Cast-In-Place Replaceable Tactile<br />
Installation Procedure<br />
Be sure to read and understand all of these instructions before you begin.<br />
A. The physical characteristics of the concrete shall be as specified in the contract<br />
documents while maintaining a slump range of 4-7 inches to permit the solid<br />
placement of the <strong>ADA</strong> Cast-In-Place Replaceable Tactile Unit (<strong>ADA</strong>REP) in the<br />
wet cement.<br />
B. The concrete shall be poured and finished level, true and smooth to<br />
the required dimensions prior to the placement of the <strong>ADA</strong>REP unit.<br />
C. Place the <strong>ADA</strong>REP unit 6-8 inches from the curb line. Working in a<br />
grid pattern, tamp the <strong>ADA</strong>REP unit into the wet concrete using a rubber<br />
mallet and a piece of wood. Continue this process until all of the air has<br />
been released, and the <strong>ADA</strong>REP unit surface is flush with the surrounding area.<br />
IMPORTANT: Avoid striking the surface of the <strong>ADA</strong>REP unit directly.<br />
D. Following the placement, the <strong>ADA</strong>REP unit elevation should be checked to<br />
the adjacent surface with a straight edge. The <strong>ADA</strong>REP unit elevation should<br />
be consistent with the Contract Drawings and Specifications. Any required<br />
adjustments must be made prior to the time when the concrete begins to set.<br />
E. Important Notice to Installer: To allow for expansion and contraction,<br />
after tile is installed, use a 1/4” finish edge trowel around entire perimeter. On a continous<br />
run, be sure to space each unit 1/8” apart.<br />
F. When you are confident that the <strong>ADA</strong>REP unit is in place and no further adjustments<br />
are needed, place a cinder block on both ends to hold the <strong>ADA</strong>REP unit in<br />
place while the concrete sets.<br />
G. During and after the <strong>ADA</strong>REP unit installation, as well as the concrete curing<br />
stage, no walking or external forces can be placed on the <strong>ADA</strong>REP unit. The area<br />
must be protected from pedestrian traffic until concrete is cured. The <strong>ADA</strong>REP<br />
Warning Surface will be ready for pedestrian traffic within 2-4 hours.<br />
H. Be sure to remove plastic<br />
protective covering from the face<br />
of the <strong>ADA</strong>REP Unit once the<br />
concrete is cured.<br />
*Not recommended or warrantied for<br />
asphalt installation.<br />
Do not cut Cast-In-Place Replaceable Tactile. Use an appropriate<br />
sized tactile or Radius Tactile to fit the requirement.<br />
Contact manufacturer for more details.<br />
PRODUCT SIZES<br />
2’x3’ 2’x4’ 2’x5’<br />
3’x4’ 3’x5’<br />
APPLICATION<br />
Fresh Pour<br />
Concrete Ramps<br />
& Replacement<br />
6<br />
www.adatile.com • 800-372-0519
Cast-In-Place Replaceable Tactile<br />
(WET-SET)<br />
Replacement Procedure<br />
Be sure to read and understand all of these<br />
instructions before you begin.<br />
A. Lift the existing composite bolt cap from each anchor location on the<br />
<strong>ADA</strong> Cast-In-Place Replaceable Tactile unit (<strong>ADA</strong>REP) with a flat head<br />
screw driver.<br />
B. Remove the existing 1/2” x 1½” stainless steel bolts from each anchor<br />
location on the <strong>ADA</strong>REP unit with a ratchet. Save & reuse.<br />
C. Tap around all sides of the <strong>ADA</strong>REP unit and across the middle with a<br />
rubber mallet, working in a grid pattern.<br />
D. Pry the existing <strong>ADA</strong>REP unit from the concrete ramp with a small<br />
prybar, working around the edges until it can be lifted cleanly away.<br />
E. Be sure to remove all small debris and dust from the existing impression<br />
in the concrete ramp.<br />
IMPORTANT: Be careful not to get debris into anchor locations.<br />
F. Replace new <strong>ADA</strong>REP unit, of same size and orientation, into impression<br />
in concrete ramp. Lightly tamp down the <strong>ADA</strong>REP unit with a rubber<br />
mallet and a piece of wood. Continue this process until the <strong>ADA</strong>REP unit<br />
is set firmly into existing impression in concrete ramp.<br />
IMPORTANT: Avoid striking the <strong>ADA</strong>REP unit directly.<br />
G. Bolt existing 1/2” x 1½” stainless steel bolts back into each anchor location<br />
on new <strong>ADA</strong>REP unit.<br />
H. Snap a new composite bolt cap provided, into each anchor location<br />
on the <strong>ADA</strong>REP unit. The <strong>ADA</strong>REP unit is ready for pedestrian<br />
traffic immediately after installation is complete.<br />
View additional photos, drawings and<br />
specifications on our website: www.adatile.com.<br />
Call (800) 372-0519 with any questions.<br />
U.S. Patent<br />
No. 7,779,581<br />
www.adatile.com • 800-372-0519<br />
7
24.0<br />
21.6<br />
14.4<br />
PATENT PENDING<br />
B<br />
B<br />
Cast-In-Place Replaceable Tactile<br />
DOME GEOMETRY<br />
In accordance with <strong>ADA</strong> Regulations for Detectable Warning on Curb Ramps: Raised<br />
truncated domes with a diameter of nominal 0.9”, a height of nominal 0.2” and a<br />
center-to-center spacing of 2.35”.<br />
PANEL DIMENSIONS<br />
VIEW -B<br />
.090<br />
<strong>ADA</strong> Cast-In-Place .045<br />
DEG. HIGH POINTS<br />
Replaceable TYP. .900 Tactile units (<strong>ADA</strong>REP) are available in 24” x 36”,<br />
DIA. TYP.<br />
24” x 48”, 24” x 60”, .500<br />
60.000°<br />
DIA. TOP<br />
36”<br />
OF<br />
x<br />
DOMES<br />
48” and 36” x 60” sizes. <strong>ADA</strong>REP units may also be custom<br />
1.375<br />
configured to accommodate specific project DIA.(4) requirements. <strong>ADA</strong>REP units measure<br />
1.125<br />
DIA.(4)<br />
¼” nominal thickness and feature a ⅜” thick x 1” wide perimeter “flange.”<br />
MATERIAL<br />
1.250<br />
Inline Dome Pattern<br />
VIEW-D<br />
15 - EQUAL SPACES NOTE: US PATENT PENDING APPEARS ON<br />
TOP SIDE OF PART AS SHOWN.<br />
AIR VENTS AROUND THE<br />
OUTSIDE EDGES OF PANEL<br />
2.350<br />
A homogenous glass and carbon composite which is colorfast and UV stable.<br />
Truncated domes are fiberglass reinforced for enhanced durability. The color of the<br />
<strong>ADA</strong>REP unit is uniform throughout and does not rely R0.250 on any type of paint coating to achieve color stability. Standard colors<br />
TYP.<br />
include: Federal Yellow, Brick Red, Clay Red, Safety Red, Blue, Dark Gray and Black. For superior wheelchair, walker and<br />
HEX HEAD BOLTS & WASHER 4-PL.<br />
shopping cart mobility, truncated domes have a center-to-center (horizontally and vertically) spacing of 2.35 inches.<br />
0.870<br />
0.245<br />
0.200<br />
0.625<br />
0.312<br />
0.062<br />
0.250<br />
34.286<br />
CAP COVER<br />
0.6250<br />
(4)<br />
0.875<br />
(4)<br />
PHYSICAL CHARACTERISTICS<br />
Compressive Strength 28,900 psi ASTM D 695<br />
Flexural Strength 29,300 psi ASTM D 790<br />
Water Absorption .07% ASTM D 570<br />
Slip Resistance 1.18 Dry, 1.05 Wet ASTM C 1028<br />
Flame Spread Index 20 ASTM E 84<br />
Salt Spray No Change (200 hours) ASTM B 117<br />
Chemical Stain Testing No Deterioration ASTM 1308<br />
Abrasion Resistance 549 ASTM C 501<br />
Accelerated Weathering Delta E
Cast-In-Place Replaceable Tactile<br />
(WET-SET)<br />
24”x36” Tile<br />
2.35” Dome Spacing<br />
VIEW -B<br />
.090 DEG. POINTS<br />
.045 HIGH TYP.<br />
.450<br />
DIA. TOP OF DOMES<br />
.900<br />
DIA. TYP.<br />
1.375<br />
DIA.(8)<br />
1.125<br />
DIA.(8)<br />
VIEW -B 3 x SIZE<br />
CAP COVER<br />
0.6250<br />
(8)<br />
0.875<br />
(8)<br />
TOP VIEW<br />
34.286<br />
15 - EQUAL SPACES<br />
SIDE VIEW<br />
A<br />
R0.250<br />
TYP.<br />
HEX HEAD BOLTS & WASHER 8-PL.<br />
AIR VENTS LOCATED ON<br />
THE ENDS OF THE TWS UNIT<br />
BOTTOM VIEW<br />
9 - EQUAL SPACES<br />
21.600 1.200<br />
A<br />
US<br />
60.000°<br />
PATENT # 7,779,581<br />
24.000<br />
14.400<br />
0.062<br />
0.250<br />
1.250<br />
NOTE: U.S. PATENT # 7,779,581 APPEARS ON<br />
TOP SIDE OF PART AS SHOWN.<br />
2.350<br />
WWW.<strong>ADA</strong>TILE.COM<br />
U.S. PATENT<br />
# 7,779,581<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
(800)372-0519<br />
P.O. Box 3<br />
N.Billerica, Ma. 01862<br />
2.350<br />
VIEW-D<br />
36.000<br />
27.429<br />
SECTION A-A<br />
VIEW - " D" 2 x SIZE<br />
FIELD DOT 7 DOME LAYOUT<br />
TRADE PART NO.<br />
TACTILE WARNING SURFACE 2436NV8REP_<br />
MATERIAL<br />
SMC COMPOSITE<br />
PROJECT<br />
WET SET <strong>ADA</strong> STD REPLACEABLE TACTILE<br />
WARNING SURFACE UNIT<br />
8-BOLT LOCATIONS<br />
2.350" IN LINE TRUNCATED DOME PATTERN<br />
PART SIZE 24" x 36"<br />
PLANS AND DETAILS<br />
DRAWING NO.<br />
DATE<br />
<strong>ADA</strong>-REP2436<br />
1.200<br />
0.722<br />
0.967<br />
0.245<br />
0.200<br />
0.500<br />
0.22<br />
www.adatile.com • 800-372-0519<br />
9
Cast-In-Place Replaceable Tactile<br />
24”x48” Tile<br />
2.35” Dome Spacing<br />
VIEW -B 3 x SIZE<br />
HEX HEAD BOLTS & WASHER 8-PL.<br />
R 0.250<br />
TYP.<br />
0.722<br />
0.062<br />
0.500<br />
0.250<br />
(8)<br />
1.375<br />
DIA. (8)<br />
1.125<br />
DIA. (8)<br />
0.6250<br />
(8)<br />
0.875<br />
(8)<br />
.450<br />
DIA. TOP OF DOMES<br />
0.967 24.000<br />
1.200<br />
21.600<br />
0.245<br />
14.400<br />
0.200<br />
0.22<br />
60.000°<br />
.090 DEG. POINTS<br />
.045 HIGH TYP.<br />
.900<br />
DIA. TYP.<br />
CAP COVER<br />
VIEW -B<br />
SECTION A-A<br />
SIDE VIEW<br />
VIEW-D<br />
20 - EQUAL SPACES<br />
45.714<br />
1.250<br />
TOP VIEW<br />
A<br />
US<br />
9 - EQUAL SPACES<br />
1.200<br />
18.286 20.571<br />
9.1429 2.286 9.1429<br />
48.000<br />
PATENT # 7,779,581<br />
VIEW - " D" 2 x SIZE<br />
FIELD DOT 7 DOME LAYOUT<br />
2.350<br />
2.350<br />
NOTE: U.S. PATENT # 7,779,581 APPEARS ON<br />
TOP SIDE OF PART AS SHOWN.<br />
AIR VENTS LOCATED ON<br />
THE ENDS OF THE TWS UNIT<br />
A<br />
BOTTOM VIEW<br />
WWW.<strong>ADA</strong>TILE.COM<br />
U.S. PATENT<br />
# 7,779,581<br />
TRADE PART NO.<br />
TACTILE WARNING SURFACE 2448NV8REP_<br />
MATERIAL<br />
SMC COMPOSITE<br />
PROJECT<br />
WET SET <strong>ADA</strong> REPLACEABLE TACTILE<br />
WARNING SURFACE UNIT<br />
8-BOLT LOCATIONS<br />
2.350" IN LINE TRUNCATED DOME PATTERN<br />
PART SIZE 24" x 48"<br />
PLANS AND DETAILS<br />
DRAWING NO.<br />
DATE<br />
<strong>ADA</strong>-REP2448<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
(800)372-0519<br />
P.O. Box 3<br />
N.Billerica, Ma. 01862<br />
10<br />
www.adatile.com • 800-372-0519
Cast-In-Place Replaceable Tactile<br />
(WET-SET)<br />
24”x60” Tile<br />
2.35” Dome Spacing<br />
0.722<br />
0.062<br />
0.500<br />
0.250<br />
(11)<br />
0.6250<br />
(11)<br />
0.875<br />
(11)<br />
9 - EQUAL SPACES<br />
B<br />
TOP VIEW<br />
1.250<br />
57.143<br />
25 - EQUAL SPACES<br />
SIDE VIEW<br />
VIEW -B<br />
CAP COVER<br />
.090 DEG. POINTS<br />
.045 HIGH TYP.<br />
.900<br />
DIA. TYP. 60.000°<br />
.450<br />
DIA. TOP OF DOMES<br />
1.375<br />
DIA.(11)<br />
1.125<br />
DIA.(11)<br />
R0.250<br />
TYP.<br />
HEX HEAD BOLTS & WASHER 11-PL.<br />
VIEW -B 3 x SIZE<br />
US PATENT # 7,779,581<br />
B<br />
AIR VENTS LOCATED ON<br />
THE ENDS OF THE PANEL<br />
BOTTOM VIEW<br />
0.967<br />
24.000<br />
21.600<br />
14.400<br />
1.200<br />
2.350<br />
60.000<br />
18.286 13.714 18.286<br />
6.314 6.314<br />
VIEW-D<br />
SECTION B-B<br />
NOTE: U.S. PATENT # 7,779,581 APPEARS ON<br />
TOP SIDE OF PART AS SHOWN.<br />
2.350<br />
VIEW - " D" 2 x SIZE<br />
FIELD DOT 7 DOME LAYOUT<br />
WWW.<strong>ADA</strong>TILE.COM<br />
U.S. PATENT<br />
# 7,779,581<br />
TRADE PART NO.<br />
TACTILE WARNING SURFACE 2460NV11REP_<br />
MATERIAL<br />
SMC COMPOSITE<br />
PROJECT<br />
WET SET <strong>ADA</strong> REPLACEABLE TACTILE<br />
WARNING SURFACE UNIT<br />
11-BOLT LOCATIONS<br />
2.350" IN LINE TRUNCATED DOME PATTERN<br />
PART SIZE 24" x 60"<br />
PLANS AND DETAILS<br />
DRAWING NO.<br />
DATE<br />
<strong>ADA</strong>-REP2460<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
(800)372-0519<br />
P.O. Box 3<br />
N.Billerica, Ma. 01862<br />
0.245<br />
0.200<br />
0.22<br />
1.200<br />
www.adatile.com • 800-372-0519<br />
11
Cast-In-Place Replaceable Tactile<br />
36”x48” Tile<br />
2.35” Dome Spacing<br />
VIEW-D<br />
1.125<br />
36.000<br />
PART O.A.<br />
33.750 1.125<br />
15 - EQUAL SPACES<br />
VIEW -B 3 x SIZE<br />
HEX HEAD BOLTS & WASHER 12-PL.<br />
R 0.250<br />
TYP.<br />
0.562<br />
0.062<br />
0.250<br />
(12)<br />
0.722<br />
0.500<br />
0.967<br />
0.245<br />
0.200<br />
1.375<br />
DIA. (12)<br />
1.125<br />
DIA. (12)<br />
0.6250<br />
(12)<br />
0.875<br />
(12)<br />
.450<br />
DIA. TOP OF DOMES<br />
60.000°<br />
.090 DEG. POINTS<br />
.045 HIGH TYP.<br />
.900<br />
DIA. TYP.<br />
CAP COVER<br />
VIEW-B<br />
SECTION B-B<br />
SIDE VIEW<br />
AIR VENTS AROUND THE<br />
OUTSIDE EDGES OF PANEL<br />
20 - EQUAL SPACES<br />
45.714<br />
1.143<br />
1.143<br />
A A<br />
13.500 13.500<br />
18.286 20.571<br />
2.286<br />
PART O.A.<br />
48.000<br />
VIEW - " D" 2 x SIZE<br />
FIELD DOT 13 ON DOME LAYOUT<br />
2.350<br />
2.350<br />
NOTE: US PATENT PENDING APPEARS ON<br />
TOP SIDE OF PART AS SHOWN.<br />
BOTTOM VIEW<br />
WWW.<strong>ADA</strong>TILE.COM<br />
U.S. Patent No.7,779,581<br />
MATERIAL LIST<br />
ITEM<br />
DESCRIPTION<br />
PART NO. QT'Y<br />
1<br />
2<br />
3<br />
4<br />
SCALE<br />
AS NOTED<br />
FULL SIZE<br />
TRADE<br />
DETECTABLE WARNING SURFACE<br />
PART NO.<br />
SEE MATERIAL LIST<br />
MATERIAL<br />
PROJECT<br />
WET SET <strong>ADA</strong> REPLACEABLE TACTILE<br />
WARNING SURFACE UNIT<br />
2.375" IN LINE TRUNCATED DOME PATTERN<br />
PART SIZE 36" x 48"<br />
PLANS AND DETAILS<br />
DRAWING NO. REV. NO.<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
P.O. Box 3<br />
N.Billerica, Ma. 01862<br />
12<br />
www.adatile.com • 800-372-0519
NOTE: US PATENT PENDING APPEARS ON<br />
TOP SIDE OF PART AS SHOWN.<br />
2.350<br />
2.350<br />
VIEW - " D" 2 x SIZE<br />
FIELD DOT 13 ON DOME LAYOUT<br />
BOTTOM VIEW<br />
U.S. Patent No.7,779,581<br />
MATERIAL LIST<br />
ITEM<br />
DESCRIPTION<br />
PART NO. QT'Y<br />
SCALE<br />
AS NOTED<br />
FULL SIZE<br />
TRADE<br />
PART NO.<br />
DETECTABLE WARNING SURFACE<br />
SEE MATERIAL LIST<br />
MATERIAL<br />
PROJECT<br />
WET SET <strong>ADA</strong> REPLACEABLE TACTILE<br />
WARNING SURFACE UNIT<br />
2.375" IN LINE TRUNCATED DOME PATTERN<br />
PART SIZE 36" x 60"<br />
PLANS AND DETAILS<br />
DRAWING NO. REV. NO.<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
P.O. Box 3<br />
N.Billerica, Ma. 01862<br />
1<br />
2<br />
3<br />
4<br />
Cast-In-Place Replaceable Tactile<br />
(WET-SET)<br />
36x60” Tile<br />
2.35” Dome Spacing<br />
1.125<br />
36.000<br />
PART O.A.<br />
33.750 1.125<br />
15 - EQUAL SPACES<br />
13.500 13.500<br />
"B"<br />
VIEW-D<br />
59.429<br />
16.000 18.286 16.000<br />
1.143 1.143<br />
57.143<br />
20 - EQUAL SPACES<br />
SIDE VIEW<br />
AIR VENTS AROUND THE<br />
OUTSIDE EDGES OF PANEL<br />
SECTION B-B<br />
VIEW-B<br />
"B"<br />
0.722<br />
0.562<br />
0.062<br />
0.500<br />
0.250<br />
(12)<br />
0.967<br />
0.245<br />
0.200<br />
0.6250<br />
(12)<br />
0.875<br />
(12)<br />
.090 DEG. POINTS<br />
.045 HIGH TYP.<br />
.900<br />
DIA. TYP.<br />
60.000°<br />
.450<br />
DIA. TOP OF DOMES<br />
1.375<br />
DIA. (12)<br />
1.125<br />
DIA. (12)<br />
CAP COVER<br />
R 0.250<br />
TYP.<br />
VIEW -B 3 x SIZE<br />
HEX HEAD BOLTS & WASHER 12-PL.<br />
WWW.<strong>ADA</strong>TILE.COM<br />
www.adatile.com • 800-372-0519<br />
13
U.S. Patent<br />
No. 7,779,581<br />
Radius Tactile<br />
cast-in-place replaceable (wet-set)<br />
or surface mount<br />
14
Proudly Made in<br />
the U.S.A.<br />
15
Radius Tactile - Replaceable<br />
Installation Procedure<br />
Be sure to read and understand all of these<br />
instructions before you begin.<br />
A. The physical characteristics of the concrete shall be as specified in the contract<br />
documents while maintaining a slump range of 4-7 inches to permit the solid<br />
placement of the <strong>ADA</strong> Replaceable Tactile Unit (<strong>ADA</strong>REP) in the wet cement.<br />
B. The concrete shall be poured and finished level, true and smooth to the<br />
required dimensions prior to the placement of the <strong>ADA</strong>REP unit.<br />
C. Working in a grid pattern, tamp the <strong>ADA</strong>REP unit into the wet concrete<br />
using a rubber mallet and a piece of wood. Continue this process until all of the air<br />
has been released, and the <strong>ADA</strong>REP unit surface is flush with the surrounding area.<br />
IMPORTANT: Avoid striking the surface of the <strong>ADA</strong>REP unit directly.<br />
D. Following the placement, the <strong>ADA</strong>REP unit elevation should be checked to<br />
the adjacent surface with a straight edge. The <strong>ADA</strong>REP unit elevation should<br />
be consistent with the Contract Drawings and Specifications. Any required<br />
adjustments must be made prior to the time when the concrete begins to set.<br />
E. Important Notice to Installer: To allow for expansion and contraction,<br />
after tile is installed, use a 1/4” finish edge trowel around entire perimeter. On a continous<br />
run, be sure to space each unit 1/8” apart.<br />
F. When you are confident that the <strong>ADA</strong>REP unit is in place and no further<br />
adjustments are needed, place a cinder block on both ends to hold the <strong>ADA</strong>REP<br />
unit in place while the concrete sets.<br />
G. During and after the <strong>ADA</strong>REP unit installation, as well as the concrete curing<br />
stage, no walking or external forces can be placed on the <strong>ADA</strong>REP unit. The area<br />
must be protected from pedestrian traffic until concrete is cured. The <strong>ADA</strong>REP<br />
Warning Surface will be ready for pedestrian traffic within 2-4 hours.<br />
H. Be sure to remove plastic protective<br />
covering from the face of the <strong>ADA</strong>REP<br />
Unit once the concrete is cured.<br />
*Not recommended or warrantied for<br />
asphalt installation.<br />
View additional photos, drawings and specifications<br />
on our website: www.adatile.com.<br />
Call (800) 372-0519 with any questions.<br />
PRODUCT SIZES<br />
2’ x 33¼”<br />
APPLICATION<br />
Fresh Pour<br />
Concrete Ramps<br />
& Replacement<br />
16<br />
www.adatile.com • 800-372-0519
Radius Tactile - Replaceable<br />
(WET-SET)<br />
Replacement Procedure<br />
Be sure to read and understand all of these<br />
instructions before you begin.<br />
A. Lift the existing composite bolt cap from each anchor location on the <strong>ADA</strong><br />
Replaceable Tactile unit (<strong>ADA</strong>REP) with a flat head screw driver.<br />
B. Remove the existing 1/2” x 1½” stainless steel bolts from each anchor location<br />
on the <strong>ADA</strong>REP unit with a ratchet. Save & reuse.<br />
C. Tap around all sides of the <strong>ADA</strong>REP unit and across the middle with a rubber<br />
mallet, working in a grid pattern.<br />
D. Pry the existing <strong>ADA</strong>REP unit from the concrete ramp with a small<br />
prybar, working around the edges until it can be lifted cleanly away.<br />
E. Be sure to remove all small debris and dust from the existing impression<br />
in the concrete ramp.<br />
IMPORTANT: Be careful not to get debris into anchor locations.<br />
F. Replace new <strong>ADA</strong>REP unit into impression in concrete ramp. Lightly<br />
tamp down the <strong>ADA</strong>REP unit with a rubber mallet and a piece of wood.<br />
Continue this process until the <strong>ADA</strong>REP unit is set firmly into existing<br />
impression in concrete ramp.<br />
IMPORTANT: Avoid striking the <strong>ADA</strong>REP unit directly.<br />
G. Bolt existing 1/2” x 1½” stainless steel bolts back into each anchor location<br />
on new <strong>ADA</strong>REP unit.<br />
H. Snap a new composite bolt cap provided, into each anchor location<br />
on the <strong>ADA</strong>REP unit. The <strong>ADA</strong>REP unit is ready for pedestrian<br />
traffic immediately after installation is complete.<br />
View additional photos, drawings and<br />
specifications on our website: www.adatile.com.<br />
Call (800) 372-0519 with any questions.<br />
U.S. Patent<br />
No. 7,779,581<br />
www.adatile.com • 800-372-0519<br />
17
Radius Tactile - Replaceable<br />
Inline Dome Pattern<br />
DOME GEOMETRY<br />
<strong>ADA</strong>AG, PROWAG and <strong>ADA</strong>/ABA Compliant in-line truncated dome pattern.<br />
UNIVERSAL RADIUS TWS PRODUCT<br />
Universal Radius TWS <strong>Product</strong> is scored for a 10’, 15’ and 20’ radial condition and may be cut by a table saw to<br />
accommodate site conditions.<br />
Radius Panel Sizes<br />
• <strong>ADA</strong> Replaceable TWS Unit: 24” x 33¼”, 6 recessed and capped ½” x 1½” bolts with concrete inserts and heavy duty<br />
perimeter detail.<br />
MATERIAL<br />
A homogenous glass and carbon reinforced composite which is colorfast and UV stable. Truncated domes are fiberglass<br />
reinforced for enhanced durability. The color of the TWS Unit is uniform throughout and does not rely on any type of<br />
paint coating to achieve color stability. Standard colors: Federal Yellow, Brick Red, Clay Red, Safety Red, Blue, Dark<br />
Gray, and Black.<br />
PHYSICAL CHARACTERISTICS<br />
Compressive Strength 28,900 psi ASTM D 695<br />
Flexural Strength 29,300 psi ASTM D 790<br />
Slip Resistance 1.18 Dry, 1.05 Wet ASTM C 1028<br />
Chemical Stain Testing No Deterioration ASTM D 543<br />
Abrasion Resistance 549 ASTM C 501<br />
Accelerated Weathering Delta E
Radius Tactile - Replaceable<br />
(WET-SET)<br />
24”x33.25” Tile<br />
2.35” Dome Spacing<br />
33.252<br />
REF. DIM BEFORE CUT<br />
VIEW - D TOP VIEW<br />
8-BOLT LOCATIONS<br />
FRONT VIEW<br />
SECTION A-A<br />
SIDE VIEW<br />
VIEW-E 2 x SIZE<br />
VIEW-E<br />
BOTTOM VIEW<br />
1.700<br />
2.350<br />
A<br />
A<br />
.090 DEG. POINTS<br />
.045 HIGH TYP.<br />
0.450<br />
DIA. TOP OF DOMES<br />
0.900<br />
DIA. TYP.<br />
60°0'<br />
LABELED RADIUS<br />
CUT LINES FOR<br />
10', 15', 20' RADIAL<br />
CAP COVER<br />
R0.250<br />
TYP.<br />
HEX HEAD BOLTS & WASHER 8-PL.<br />
0.967<br />
0.722<br />
0.160<br />
0.875<br />
(8)<br />
0.625<br />
(8)<br />
24.000<br />
0.159<br />
VIEW-B 3 x SIZE<br />
'A' DIMENSION AFTER CUT<br />
SEE CHART<br />
'B' DIMENSION AFTER CUT<br />
SEE CHART<br />
VIEW - " D" 2 x SIZE<br />
FIELD DOT 13 ON DOME LAYOUT<br />
WWW.<strong>ADA</strong>TILE.COM<br />
U.S. PATENT<br />
# 7,779,581<br />
+ PATENT PENDING<br />
WET SET <strong>ADA</strong> STD REPLACEABLE TACTILE<br />
WARNING SURFACE UNIT<br />
8-BOLT LOCATIONS<br />
2.350" IN LINE TRUNCATED DOME PATTERN<br />
PART SIZE 24" x 10', 15', 20' RADIAL<br />
PLANS AND DETAILS<br />
<strong>ADA</strong>-REP24RAD<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
(800)372-0519<br />
P.O. Box 3<br />
N.Billerica, Ma. 01862<br />
0.715<br />
(8)<br />
10' RADIUS<br />
11.280<br />
10.392<br />
1.375<br />
DIA.(8)<br />
1.125<br />
DIA.(8)<br />
TRADE PART NO.<br />
TACTILE WARNING SURFACE 24RAD8REP_<br />
MATERIAL<br />
SMC COMPOSITE<br />
PROJECT<br />
DRAWING NO.<br />
DATE<br />
11.280<br />
14.375<br />
10.392<br />
0.563<br />
0.062<br />
0.245<br />
0.200<br />
DOMES<br />
www.adatile.com • 800-372-0519<br />
19
Radius Tactile - Surface Mount<br />
Installation Procedure<br />
Be sure to read and understand all of these instructions before you begin.<br />
A. The installation area should be cleaned of all debris, oil and grease, making<br />
sure the area is completely free of moisture. Tactile Panel may be surface<br />
mounted on existing pre-cleaned substrate.<br />
B. Lay out the Tactile Panel on the substrate as it will appear when installed.<br />
• If required, the Tactile Panel may be cut using a table saw and diamond<br />
tipped blade. 10’, 15’, & 20’ radius are pre-scored on backside of tactile<br />
panel. See web site for more details.<br />
C. Place a 3/8” bead of adhesive on the frame of the bottom of each Tactile<br />
Panel. Adhesive yield: 10SF per 10 ounce cartridge. 18-24SF per 20 ounce<br />
cartridge.<br />
D. Set the Tactile Panel in the installation area. Make all necessary adjustments<br />
prior to fastening.<br />
E. Fasteners shall be installed in pre-formed fastener locations. Holes shall be<br />
drilled using a hammer drill with 1/4” x 2” min SDS bits. The drilled holes<br />
must be a minimum of 2” deep. Place fasteners in hole and hammer into<br />
place.<br />
• If additional fasteners are required, use a 1/2”, six point, 82 degree<br />
countersink to add a new fastener location. Follow the same drilling<br />
method for installing the fastener.<br />
F. Caulk around perimeter of entire installation using BASF NP1 or<br />
equivalent.<br />
• All concrete dust present on the Tactile Panel resulting from the drilling<br />
process must be cleaned off of the Tactile Panel prior to using any<br />
caulking materials.<br />
*Not recommended or warrantied for asphalt installation.<br />
View additional photos, drawings and specifications on our website:<br />
www.adatile.com. Call (800) 372-0519 with any questions.<br />
PRODUCT SIZES<br />
2’ x 33¼”<br />
APPLICATION<br />
Existing<br />
Concrete Ramps<br />
www.adatile.com • 800-372-0519<br />
21
Radius Tactile - Surface Mount<br />
Inline Dome Pattern<br />
DOME GEOMETRY<br />
<strong>ADA</strong>AG, PROWAG and <strong>ADA</strong>/ABA Compliant in-line truncated dome pattern.<br />
UNIVERSAL RADIUS TWS Panel<br />
Universal Radius TWS Panel is scored on backside for a 10’, 15’ and 20’ radial condition and may be cut by a table saw<br />
to accommodate site conditions.<br />
Radius Panel Sizes<br />
• <strong>ADA</strong> Surface Applied TWS Panel: 24” x 33¼”, 16 composite sleeve anchors with stainless steel pins, adhesive &<br />
perimeter sealant.<br />
MATERIAL<br />
A homogenous glass and carbon reinforced composite which is colorfast and UV stable. Truncated domes are fiberglass<br />
reinforced for enhanced durability. The color of the TWS Unit is uniform throughout and does not rely on any type of<br />
paint coating to achieve color stability. Standard colors: Federal Yellow, Brick Red, Clay Red, Safety Red, Blue, Dark<br />
Gray, and Black.<br />
PHYSICAL CHARACTERISTICS<br />
Compressive Strength 28,900 psi ASTM D 695<br />
Flexural Strength 29,300 psi ASTM D 790<br />
Slip Resistance 1.18 Dry, 1.05 Wet ASTM C 1028<br />
Chemical Stain Testing No Deterioration ASTM D 543<br />
Abrasion Resistance 549 ASTM C 501<br />
Accelerated Weathering Delta E
Radius Tactile - Surface Mount<br />
24”x33.25” Tile<br />
2.35” Dome Spacing<br />
33.260<br />
REF DIM BEFORE CUT<br />
A<br />
27.500<br />
REF DIM BEFORE CUT<br />
VIEW A<br />
16- ANCHOR LOCATIONS<br />
LABELED RADIUS<br />
CUT LINES<br />
.005 RAISED LETTERS<br />
.045 RAISED CUT LINES<br />
.436<br />
DIA<br />
70.0°<br />
16-PL<br />
1/4" x 1 1/2" LG.<br />
EXPANSION ANCHOR<br />
.900<br />
DIA. 150-PL<br />
MATERIAL LIST<br />
ITEM<br />
DESCRIPTION<br />
PART NO. QT'Y<br />
1<br />
2<br />
3<br />
4<br />
SCALE<br />
AS NOTED<br />
FULL SIZE<br />
TRADE<br />
PART NO.<br />
DETECTABLE WARNING SURFACE SEE MATERIAL LIST<br />
MATERIAL<br />
PROJECT<br />
24" X 10', 15', 20' RADIAL<br />
SOUND ATTENUATING<br />
CURB RAMP TILE 2.350" (INLINE DOME)<br />
PLANS AND DETAILS<br />
DRAWING NO. REV. NO.<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
P.O. Box 3<br />
N.Billerica, Ma. 01862<br />
45.0°<br />
VIEW B 2X SCALE<br />
TILE INSTALLATION<br />
VIEW-B 4x SCALE<br />
2.350<br />
24.000<br />
.432<br />
O.A.<br />
.188<br />
PANEL<br />
.045<br />
POINTS<br />
.200<br />
DOME 150-PL<br />
.188<br />
PANEL<br />
.045<br />
CUT LINE<br />
A<br />
TOP VIEW<br />
FRONT VIEW<br />
VIEW B<br />
SECTION A-A<br />
1.700<br />
VIEW A 2X SCALE<br />
VIEW C<br />
SIDE VIEW BOTTOM VIEW<br />
VIEW C 2X SCALE<br />
WWW.<strong>ADA</strong>TILE.COM<br />
<strong>ADA</strong> SURFACE PANEL APPLIED<br />
DETECTABLKE TWS<br />
www.adatile.com • 800-372-0519<br />
23
Surface Mount<br />
Tactile<br />
24
Proudly Made in<br />
the U.S.A.<br />
25
Surface Mount Tactile<br />
Installation Procedure<br />
Be sure to read and understand all of these<br />
instructions before you begin.<br />
A. The installation area should be cleaned of all debris, oil and grease, making<br />
sure the area is completely free of moisture. Tactile Panel may be surface<br />
mounted on existing pre-cleaned substrate.<br />
B. Lay out the Tactile Panel on the substrate as it will appear when installed.<br />
• If required, the Tactile Panel may be cut using a table saw and marble<br />
tipped blade. See web site for more details.<br />
C. Place a 3/8” bead of adhesive on the frame of the bottom of each Tactile<br />
Panel. Adhesive yield: 10SF per 10 ounce cartridge.<br />
D. Set the Tactile Panel in the installation area. Make all necessary adjustments<br />
prior to fastening.<br />
E. Fasteners shall be installed in pre-formed fastener locations. Holes shall be<br />
drilled using a hammer drill with 1/4” x 2” min SDS bits. The drilled holes<br />
must be a minimum of 2” deep. Place fasteners in hole and hammer into place.<br />
• If additional fasteners are required, use a 1/2”, six point, 82 degree<br />
countersink to add a new fastener location. Follow the same drilling<br />
method for installing the fastener.<br />
F. Caulk around perimeter of entire installation using BASF NP1 or equivalent.<br />
• All concrete dust present on the Tactile Panel resulting from the drilling<br />
process must be cleaned off of the Tactile Panel prior to using any<br />
caulking materials.<br />
*Not recommended or warrantied for asphalt installation.<br />
PRODUCT SIZES<br />
2’x3’ 2’x4’ 2’x5’<br />
3’x4’ 3’x5’<br />
View additional photos, drawings and specifications<br />
on our website: www.adatile.com.<br />
Call (800) 372-0519 with any questions.<br />
APPLICATION<br />
Existing<br />
Concrete Ramps<br />
26<br />
www.adatile.com • 800-372-0519
DOME GEOMETRY<br />
In accordance with <strong>ADA</strong> Regulations for Detectable Warning<br />
on Curb Ramps: Raised truncated domes with a diameter<br />
of nominal 0.9”, a height of nominal 0.2”, and a centerto-center<br />
spacing of nominal 1.67” minimum and 2.35”<br />
maximum.<br />
PANEL DIMENSIONS<br />
Tactile Panels are available in 24”x36”, 24”x48”, 24”x60”,<br />
36”x48” and 36”x60” sizes and measure 3/16” thick. Panels<br />
can be custom cut to fit field conditions. All four edges of<br />
each panel have a ½” beveled edge. Each panel has 12 to<br />
24 pre-formed fastener locations based upon panel size.<br />
MATERIAL<br />
A homogenous glass and carbon reinforced composite which is colorfast and UV stable. Truncated domes are fiberglass<br />
reinforced for enhanced durability. The Tactile panel color is uniform throughout and does not rely on any type of paint<br />
coating to achieve color stability. Standard colors include: Federal Yellow, Brick Red, Clay Red, Safety Red, Blue, Dark<br />
Gray and Black.<br />
PHYSICAL CHARACTERISTICS<br />
Compressive Strength 28,900 psi ASTM D 695<br />
Flexural Strength 29,300 psi ASTM D 790<br />
Water Absorption .07% ASTM D 570<br />
Slip Resistance 1.18 Dry/1.05 Wet ASTM C 1028<br />
Flame Spread Index 20 ASTM E 84<br />
Salt Spray No Change (200 hours) ASTM B 117<br />
Chemical Stain Testing No Deterioration ASTM 1308<br />
Abrasion Resistance 549 ASTM C 501<br />
Accelerated Weathering Delta E
790<br />
1<br />
2<br />
3<br />
4<br />
Surface Mount Composite Tactile<br />
24”x36” Tile<br />
1.67” Dome Spacing<br />
24.2812<br />
PART O.A.<br />
1.2971<br />
1.6700<br />
13 - 13 EQUAL SPACES<br />
0.4425<br />
PART O.A.<br />
1.286<br />
21.709<br />
13 - EQUAL SPACES<br />
1.286<br />
R.1250<br />
4-PL.<br />
"B"<br />
0.1350<br />
WALL THICKNESS<br />
R.125<br />
4-PL.<br />
1/4" DIA. CTSK HOLES<br />
(TYP. 12 LOCATIONS)<br />
1.1467<br />
1.6700<br />
VIEW-A 4 x SCALE<br />
37.3700<br />
PART O.A.<br />
HALF SCALE<br />
1/4" DIA. CTSK HOLES<br />
(TYP. 12 LOCATIONS)<br />
"B"<br />
30°<br />
.1975<br />
.0625<br />
.7500<br />
300<br />
.200<br />
18-PL.<br />
.500<br />
4-SIDES<br />
.900<br />
DIA. 260 PL.<br />
.0625<br />
.480<br />
DIA. 18-PL.<br />
18-PL<br />
.450<br />
DIA. 260 PL.<br />
.090 DEG POINTS<br />
.045 HIGH<br />
SECTION "B" 2X SCALE<br />
.200<br />
DOME 308 PL.<br />
0.1350<br />
TILE INSTALLATION<br />
VIEW-B 4x SCALE<br />
1/4" x 1 1/2" LG.<br />
EXPANSION ANCHOR<br />
WWW.<strong>ADA</strong>TILE.COM<br />
MATERIAL LIST<br />
ITEM<br />
DESCRIPTION<br />
PART NO. QT'Y<br />
SCALE<br />
AS NOTED<br />
FULL SIZE<br />
TRADE<br />
DETECTABLE WARNING SURFACE<br />
MATERIAL<br />
PART NO.<br />
SEE MATERIAL LIST<br />
PROJECT<br />
SURFACE APPLIED DETECTABLE<br />
WARNING SURFACE SYSTEM<br />
24" x 36" SOUND ATTENUATING<br />
CURB RAMP TILE (INLINE DOME)<br />
PLANS AND DETAILS<br />
DRAWING NO. REV. NO.<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
PO Box 3<br />
N.Billerica, Ma. 01862<br />
28<br />
www.adatile.com • 800-372-0519
79°<br />
R.125<br />
4-PL.<br />
"B"<br />
R.1250<br />
4-PL.<br />
1.200<br />
2.3500<br />
VIEW-A 2x SCALE<br />
36.6500<br />
PART O.A.<br />
"B"<br />
.500<br />
4-SIDES<br />
.7500<br />
.480<br />
DIA. 18-PL.<br />
30°<br />
30°<br />
24.0000<br />
PART O.A.<br />
1.200<br />
9 -9 EQUAL SPACES<br />
2.3500<br />
PART O.A.<br />
0.4425<br />
1.2000<br />
21.6000<br />
9 - EQUAL SPACES<br />
1.2000<br />
0.1350<br />
WALL THICKNESS<br />
.1975<br />
.0625<br />
.200<br />
18-PL.<br />
.0625<br />
1/4" DIA. CTSK HOLES<br />
(TYP. 12 LOCATIONS)<br />
HALF SCALE<br />
18-PL<br />
.900<br />
DIA. 260 PL.<br />
1/4" x 1 1/2" LG.<br />
EXPANSION ANCHOR<br />
DOME 260 PL.<br />
.200<br />
1/4" DIA. CTSK HOLES<br />
(TYP. 12 LOCATIONS)<br />
.450<br />
DIA. 260 PL.<br />
SECTION "B" 2X SCALE<br />
.090 DEG POINTS<br />
.045 HIGH<br />
TILE INSTALLATION<br />
VIEW-B 4x SCALE<br />
WWW.<strong>ADA</strong>TILE.COM<br />
MATERIAL LIST<br />
ITEM DESCRIPTION<br />
PART NO. QT'Y<br />
SCALE<br />
AS NOTED<br />
FULL SIZE<br />
TRADE<br />
DETECTABLE WARNING SURFACE<br />
PART NO.<br />
SEE MATERIAL LIST<br />
MATERIAL<br />
PROJECT<br />
SURFACE APPLIED DETECTABLE<br />
WARNING SURFACE SYSTEM<br />
24" x 36" SOUND ATTENUATING<br />
CURB RAMP TILE (INLINE DOME)<br />
PLANS AND DETAILS<br />
DRAWING NO.<br />
REV. NO.<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
PO Box 3<br />
N.Billerica, Ma. 01862<br />
1<br />
2<br />
3<br />
4<br />
Surface Mount Composite Tactile<br />
24”x36” Tile<br />
2.35” Dome Spacing<br />
www.adatile.com • 800-372-0519 29
1<br />
3<br />
4<br />
79°<br />
2<br />
Surface Mount Composite Tactile<br />
24”x48” Tile<br />
1.67” Dome Spacing<br />
24.281<br />
PART O.A.<br />
1.297 1.670<br />
13 - 13 EQUAL SPACES<br />
0.443<br />
PART O.A.<br />
1.271<br />
21.709<br />
13 - EQUAL SPACES<br />
1.286<br />
R.1250<br />
4-PL.<br />
"B"<br />
0.1350<br />
WALL THICKNESS<br />
R.125<br />
4-PL.<br />
1/4" DIA. CTSK HOLES<br />
(TYP. 15 LOCATIONS)<br />
1.147<br />
1.670<br />
VIEW-A 4 x SCALE<br />
HALF SCALE<br />
1/4" DIA. CTSK HOLES<br />
(TYP. 15 LOCATIONS)<br />
.1975<br />
.0625<br />
.7500<br />
30°<br />
30°<br />
.200<br />
18-PL.<br />
.500<br />
"B" 4-SIDES<br />
49.060<br />
PART O.A.<br />
.900<br />
DIA. 260 PL.<br />
.0625<br />
.480<br />
DIA. 18-PL.<br />
18-PL<br />
.450<br />
DIA. 260 PL.<br />
.090 DEG POINTS<br />
.045 HIGH<br />
SECTION "B" 2X SCALE<br />
.200<br />
DOME 406 PL.<br />
0.1350<br />
TILE INSTALLATION<br />
VIEW-B 4x SCALE<br />
1/4" x 1 1/2" LG.<br />
EXPANSION ANCHOR<br />
WWW.<strong>ADA</strong>TILE.COM<br />
MATERIAL LIST<br />
ITEM<br />
DESCRIPTION<br />
PART NO. QT'Y<br />
SCALE<br />
AS NOTED<br />
FULL SIZE<br />
TRADE<br />
DETECTABLE WARNING SURFACE<br />
MATERIAL<br />
PART NO.<br />
SEE MATERIAL LIST<br />
PROJECT<br />
SURFACE APPLIED DETECTABLE<br />
WARNING SURFACE SYSTEM<br />
24" x 48" SOUND ATTENUATING<br />
CURB RAMP TILE (INLINE DOME)<br />
PLANS AND DETAILS<br />
DRAWING NO.<br />
REV. NO.<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
PO Box 3<br />
N.Billerica, Ma. 01862<br />
30<br />
www.adatile.com • 800-372-0519
79°<br />
1.200<br />
VIEW-A 2x SCALE<br />
.480<br />
DIA. 18-PL.<br />
30°<br />
0.4425<br />
PART O.A.<br />
0.1350<br />
WALL THICKNESS<br />
"B"<br />
R.1250<br />
4-PL.<br />
.7500<br />
.900<br />
DIA. 260 PL.<br />
1.200<br />
2.3500<br />
9 -9 EQUAL SPACES<br />
.1975<br />
.0625<br />
.200<br />
18-PL.<br />
.0625<br />
30°<br />
R.125<br />
4-PL.<br />
1/4" DIA. CTSK HOLES<br />
(TYP. 12 LOCATIONS)<br />
2.3500<br />
48.6500<br />
PART O.A.<br />
HALF SCALE<br />
"B"<br />
.500<br />
4-SIDES<br />
18-PL<br />
SECTION "B" 2X SCALE<br />
24.0000<br />
PART O.A.<br />
1.2000<br />
21.6000<br />
9 - EQUAL SPACES<br />
1.2000<br />
DOME 260 PL.<br />
.200<br />
1/4" DIA. CTSK HOLES<br />
(TYP. 12 LOCATIONS)<br />
.450<br />
DIA. 260 PL.<br />
.090 DEG POINTS<br />
.045 HIGH<br />
TILE INSTALLATION<br />
VIEW-B 4x SCALE<br />
1/4" x 1 1/2" LG.<br />
EXPANSION ANCHOR<br />
WWW.<strong>ADA</strong>TILE.COM<br />
MATERIAL LIST<br />
ITEM DESCRIPTION<br />
PART NO. QT'Y<br />
SCALE<br />
AS NOTED<br />
FULL SIZE<br />
TRADE<br />
DETECTABLE WARNING SURFACE<br />
PART NO.<br />
SEE MATERIAL LIST<br />
MATERIAL<br />
PROJECT<br />
SURFACE APPLIED DETECTABLE<br />
WARNING SURFACE SYSTEM<br />
24" x 48" SOUND ATTENUATING<br />
CURB RAMP TILE (INLINE DOME)<br />
PLANS AND DETAILS<br />
DRAWING NO. REV. NO.<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
1 Survey Circle<br />
N.Billerica, Ma. 01862<br />
1<br />
2<br />
3<br />
4<br />
Surface Mount Composite Tactile<br />
24”x48” Tile<br />
2.35” Dome Spacing<br />
www.adatile.com • 800-372-0519 31
79°<br />
1<br />
2<br />
3<br />
4<br />
Surface Mount Composite Tactile<br />
24”x60” Tile<br />
1.67” Dome Spacing<br />
24.281<br />
PART O.A.<br />
1.297<br />
1.670<br />
13 - 13 EQUAL SPACES<br />
0.443<br />
PART O.A.<br />
1.271<br />
21.709<br />
13 - EQUAL SPACES<br />
1.286<br />
R.1250<br />
4-PL.<br />
"B"<br />
0.1350<br />
WALL THICKNESS<br />
R.125<br />
4-PL.<br />
1/4" DIA. CTSK HOLES<br />
(TYP. 18 LOCATIONS)<br />
1.147<br />
1.670<br />
VIEW-A 4 x SCALE<br />
HALF SCALE<br />
1/4" DIA. CTSK HOLES<br />
(TYP. 18 LOCATIONS)<br />
.1975<br />
.0625<br />
.7500<br />
30°<br />
30°<br />
.200<br />
18-PL.<br />
.500<br />
"B" 4-SIDES<br />
60.750<br />
PART O.A.<br />
.900<br />
DIA. 260 PL.<br />
.0625<br />
.480<br />
DIA. 18-PL.<br />
18-PL<br />
.450<br />
DIA. 260 PL.<br />
.090 DEG POINTS<br />
.045 HIGH<br />
SECTION "B" 2X SCALE<br />
.200<br />
DOME 504 PL.<br />
0.1350<br />
TILE INSTALLATION<br />
VIEW-B 4x SCALE<br />
1/4" x 1 1/2" LG.<br />
EXPANSION ANCHOR<br />
WWW.<strong>ADA</strong>TILE.COM<br />
MATERIAL LIST<br />
ITEM<br />
DESCRIPTION<br />
PART NO.<br />
QT'Y<br />
SCALE<br />
AS NOTED<br />
FULL SIZE<br />
TRADE<br />
DETECTABLE WARNING SURFACE<br />
MATERIAL<br />
PART NO.<br />
SEE MATERIAL LIST<br />
PROJECT<br />
SURFACE APPLIED DETECTABLE<br />
WARNING SURFACE SYSTEM<br />
24" x 60" SOUND ATTENUATING<br />
CURB RAMP TILE (INLINE DOME)<br />
PLANS AND DETAILS<br />
DRAWING NO.<br />
REV. NO.<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
PO Box 3<br />
N.Billerica, Ma. 01862<br />
32<br />
www.adatile.com • 800-372-0519
79°<br />
R.125<br />
4-PL.<br />
60.6500<br />
PART O.A.<br />
.500<br />
4-SIDES<br />
18-PL<br />
.900<br />
DIA. 260 PL.<br />
.480<br />
DIA. 18-PL.<br />
DRAWING NO. REV. NO.<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
P.O. Box 3<br />
N.Billerica, Ma. 01862<br />
30°<br />
24.0000<br />
PART O.A.<br />
0.4425<br />
PART O.A.<br />
1.2000<br />
21.6000<br />
9 - EQUAL SPACES<br />
0.1350<br />
WALL THICKNESS<br />
.1975<br />
.0625<br />
.200<br />
18-PL.<br />
DOME 260 PL.<br />
.200<br />
1/4" DIA. CTSK HOLES<br />
(TYP. 12 LOCATIONS)<br />
"B" "B"<br />
R.1250<br />
4-PL.<br />
1.200<br />
2.3500<br />
VIEW-A 2x SCALE<br />
HALF SCALE<br />
.7500<br />
.450<br />
DIA. 260 PL.<br />
SECTION "B" 2X SCALE<br />
.090 DEG POINTS<br />
.045 HIGH<br />
TILE INSTALLATION<br />
VIEW-B 4x SCALE<br />
1/4" x 1 1/2" LG.<br />
EXPANSION ANCHOR<br />
MATERIAL LIST<br />
ITEM DESCRIPTION PART NO. QT'Y<br />
SCALE<br />
AS NOTED<br />
TRADE PART NO.<br />
DETECTABLE WARNING SURFACE<br />
SEE MATERIAL LIST<br />
MATERIAL<br />
PROJECT<br />
SURFACE APPLIED DETECTABLE<br />
WARNING SURFACE SYSTEM<br />
24" x 60" SOUND ATTENUATING<br />
CURB RAMP TILE (INLINE DOME)<br />
PLANS AND DETAILS<br />
1<br />
2<br />
3<br />
4<br />
Surface Mount Composite Tactile<br />
24”x60” Tile<br />
2.35” Dome Spacing<br />
1.200<br />
2.3500<br />
9 -9 EQUAL SPACES<br />
1.2000<br />
.0625<br />
30°<br />
1/4" DIA. CTSK HOLES<br />
(TYP. 12 LOCATIONS)<br />
WWW.<strong>ADA</strong>TILE.COM<br />
www.adatile.com • 800-372-0519 33
790<br />
1<br />
2<br />
3<br />
4<br />
Surface Mount Composite Tactile<br />
36”x48” Tile<br />
1.67” Dome Spacing<br />
36.000<br />
PART O.A.<br />
1.300<br />
1.670<br />
21 - 21 EQUAL SPACES<br />
0.443<br />
PART O.A.<br />
1.300<br />
33.399<br />
21 - EQUAL SPACES<br />
1.300<br />
R.1250<br />
4-PL.<br />
"B"<br />
0.1350<br />
WALL THICKNESS<br />
R.125<br />
4-PL.<br />
1/4" DIA. CTSK HOLES<br />
(TYP. 20 LOCATIONS)<br />
1.147 1.670<br />
VIEW-A 4 x SCALE<br />
HALF SCALE<br />
1/4" DIA. CTSK HOLES<br />
(TYP. 20 LOCATIONS)<br />
49.060<br />
PART O.A.<br />
"B"<br />
30°<br />
.1975<br />
.0625<br />
.7500<br />
300<br />
.200<br />
18-PL.<br />
.500<br />
4-SIDES<br />
.900<br />
DIA. 260 PL.<br />
.0625<br />
.450<br />
DIA. 18-PL.<br />
18-PL<br />
.450<br />
DIA. 260 PL.<br />
.090 DEG POINTS<br />
.045 HIGH<br />
SECTION "B" 4 X SCALE<br />
.200<br />
DOME 638 PL.<br />
0.1350<br />
TILE INSTALLATION<br />
VIEW-B 4x SCALE<br />
1/4" x 1 1/2" LG.<br />
EXPANSION ANCHOR<br />
WWW.<strong>ADA</strong>TILE.COM<br />
MATERIAL LIST<br />
ITEM<br />
DESCRIPTION<br />
PART NO. QT'Y<br />
SCALE<br />
AS NOTED<br />
FULL SIZE<br />
TRADE<br />
DETECTABLE WARNING SURFACE<br />
MATERIAL<br />
PART NO.<br />
SEE MATERIAL LIST<br />
PROJECT<br />
SURFACE APPLIED DETECTABLE<br />
WARNING SURFACE SYSTEM<br />
36" x 48" SOUND ATTENUATING<br />
CURB RAMP TILE (INLINE DOME)<br />
PLANS AND DETAILS<br />
DRAWING NO. REV. NO.<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
PO Box 3<br />
N.Billerica, Ma. 01862<br />
34<br />
www.adatile.com • 800-372-0519
79°<br />
"B"<br />
R.1250<br />
4-PL.<br />
1.147<br />
1.670<br />
VIEW-A 4 x SCALE<br />
60.750<br />
PART O.A.<br />
.900<br />
DIA. 260 PL.<br />
SECTION "B" 4 X SCALE<br />
36.000<br />
1.300<br />
1.670<br />
21 - 21 EQUAL SPACES<br />
0.443<br />
PART O.A.<br />
1.300<br />
33.399<br />
21 - EQUAL SPACES<br />
0.1350<br />
WALL THICKNESS<br />
.0625<br />
.500<br />
4-SIDES<br />
30°<br />
.1975<br />
.0625<br />
.200<br />
18-PL.<br />
30°<br />
R.125<br />
4-PL.<br />
1/4" DIA. CTSK HOLES<br />
(TYP. 24 LOCATIONS)<br />
HALF SCALE<br />
1/4" DIA. CTSK HOLES<br />
(TYP. 24 LOCATIONS)<br />
"B"<br />
.7500<br />
18-PL<br />
.480<br />
DIA. 18-PL.<br />
PART O.A.<br />
1.300<br />
DOME 792 PL.<br />
.200<br />
0.1350<br />
.450<br />
DIA. 260 PL.<br />
.090 DEG POINTS<br />
.045 HIGH<br />
TILE INSTALLATION<br />
VIEW-B 4x SCALE<br />
1/4" x 1 1/2" LG.<br />
EXPANSION ANCHOR<br />
WWW.<strong>ADA</strong>TILE.COM<br />
MATERIAL LIST<br />
ITEM<br />
DESCRIPTION<br />
PART NO. QT'Y<br />
SCALE<br />
AS NOTED<br />
FULL SIZE<br />
TRADE<br />
DETECTABLE WARNING SURFACE<br />
PART NO.<br />
SEE MATERIAL LIST<br />
MATERIAL<br />
PROJECT<br />
SURFACE APPLIED DETECTABLE<br />
WARNING SURFACE SYSTEM<br />
36" x 60" SOUND ATTENUATING<br />
CURB RAMP TILE (INLINE DOME)<br />
PLANS AND DETAILS<br />
DRAWING NO. REV. NO.<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
PO Box 3<br />
N.Billerica, Ma. 01862<br />
1<br />
2<br />
3<br />
4<br />
Surface Mount Composite Tactile<br />
36”x60” Tile<br />
1.67” Dome Spacing<br />
www.adatile.com • 800-372-0519 35
Cast-In-Place<br />
Tactile<br />
36
Proudly Made in<br />
the U.S.A.<br />
37
Cast-In-Place Tactile<br />
Installation Procedure<br />
Be sure to read and understand all of these instructions before you begin.<br />
A. The physical characteristics of the concrete shall be as specified in the<br />
contract documents while maintaining a slump range of 4-7 to permit the solid<br />
placement of the Tactile Unit in the wet cement.<br />
B. The concrete shall be poured and finished level, true and smooth to the required<br />
dimensions prior to the placement of the Tactile Unit.<br />
C. Place the Tactile Unit 6-8 inches from the curb line. Working in a grid pattern,<br />
tamp the Tactile Unit into the wet concrete using a rubber mallet<br />
and a piece of wood. Continue this process until all of the air has been<br />
released, and the Tactile Unit surface is flush with the surrounding area.<br />
IMPORTANT: Avoid striking the surface of the Tactile Unit directly.<br />
D. Following the placement, the Tactile Unit elevation should be checked to the adjacent<br />
surface with a straight edge. The Tactile Unit elevation should be consistent<br />
with the contract drawings and specifications. Any required<br />
adjustments must be made prior to the time when the concrete<br />
begins to set.<br />
E. Important Notice to Installer: To allow for expansion<br />
and contraction, after tile is installed, use a 1/4” finish edge trowel<br />
around entire perimeter. On a continous run, be sure to space each<br />
unit 1/8” apart.<br />
F. When you are confident that the Tactile Unit is in place, and<br />
no further adjustments are needed, place a cinder block on both<br />
ends to hold the Tactile Unit in place while the concrete sets.<br />
G. During and after the Tactile Unit installation, as well as the<br />
concrete curing stage, no walking or external forces can be<br />
placed on the Tactile Unit. The area must be protected from<br />
pedestrian traffic until concrete is cured. The Tactile Warning<br />
Surface will be ready for pedestrian traffic within 2-4 hours.<br />
H. Be sure to remove plastic protective covering from the face of<br />
the Tactile Unit once the concrete is cured.<br />
View additional photos, drawings and specifications on our website:<br />
www.adatile.com. Call (800) 372-0519 with any questions.<br />
PRODUCT SIZES<br />
2’x3’ 2’x4’ 2’x5’<br />
3’x4’ 3’x5’<br />
APPLICATION<br />
Fresh Pour<br />
Concrete<br />
Ramps<br />
38<br />
www.adatile.com • 800-372-0519
DOME GEOMETRY<br />
In accordance with <strong>ADA</strong> Regulations for Detectable Warning on Curb Ramps: Raised truncated domes with a diameter of nominal<br />
0.9”, a height of nominal 0.2”, and a center-to-center spacing of 1.67” minimum, and 2.35” maximum.<br />
PANEL DIMENSIONS<br />
Tactile Units are available in 2’x3’ , 2’x4’ , 2’x5’ , 3’x4’ and 3’x5’ sizes. Tactile Units may also be custom configured to accommodate<br />
specific project requirements. Tactile Units measure 0.25” nominal thickness and feature embedment ribs at 3” on center.<br />
MATERIAL<br />
A homogenous glass and carbon reinforced composite which is colorfast and UV stable. Truncated domes are fiberglass reinforced<br />
for enhanced durability. The color of the Tactile Unit is uniform throughout and does not rely on any type of paint coating to<br />
achieve color stability. Standard colors include: Federal Yellow, Brick<br />
Red, Clay Red, Safety Red, Blue, Dark Gray and Black.<br />
INSTALLATION<br />
Tactile Units are to be used on new curb ramp locations. The Tactile<br />
Units can be pre-filled with concrete and set in place or pressed into<br />
place in the freshly poured concrete.<br />
Cast-In-Place Tactile<br />
Inline Dome Pattern<br />
PHYSICAL CHARACTERISTICS<br />
Compressive Strength 28,900 psi ASTM D 695<br />
Flexural Strength 29,300 psi ASTM D 790<br />
Water Absorption .07% ASTM D 570<br />
Slip Resistance 1.18 Dry, 1.05 Wet ASTM C 1028<br />
Flame Spread Index 20 ASTM E 84<br />
Salt Spray No Change (200 hours) ASTM B 117<br />
Chemical Stain Testing No Deterioration ASTM 1308<br />
Abrasion Resistance 549 ASTM C 501<br />
Accelerated Weathering Delta E
1<br />
2<br />
3<br />
4<br />
Cast-In-Place Tactile<br />
24”x36” Tile<br />
1.67” Dome Spacing<br />
24.000<br />
PART O.A.<br />
1.670 1.145<br />
13 - 13 EQUAL SPACES<br />
DETAIL "B"<br />
1.145<br />
21.710 1.145<br />
13 - EQUAL SPACES<br />
DETAIL "A"<br />
DETAIL "C"<br />
1.434<br />
1.670<br />
27 - 27 EQUAL SPACES<br />
DETAIL "A"<br />
36.000<br />
PART O.A.<br />
TOP OF PANEL<br />
1.375<br />
.250<br />
0.750<br />
EQUAL SPACES OF .750<br />
.1875<br />
DETAIL "B"<br />
6.000<br />
3.000<br />
TYP.<br />
0.188<br />
+2° A/S DRAFT<br />
1.160<br />
.060<br />
.200<br />
.450<br />
DIA.<br />
.900<br />
DIA.<br />
FLANGE @ 3" C/C (SEE PLAN<br />
FOR ORIENTATION)<br />
.1875<br />
0.625" DIA. HOLE<br />
EMBEDMENT FLANGES<br />
AS SHOWN IN PLAN<br />
.0600<br />
DETAIL "C"<br />
0.090 0.090<br />
0.045<br />
90°<br />
0.625" DIA. HOLE<br />
EMBEDMENT FLANGES<br />
BOTTOM OF PANEL<br />
INTERNAL EMBEDMENT<br />
FLANGE @ 3" C/C<br />
36.000<br />
PART O.A.<br />
90°<br />
0.045<br />
24.000<br />
PART O.A.<br />
WWW.<strong>ADA</strong>TILE.COM<br />
MATERIAL LIST<br />
ITEM<br />
DESCRIPTION<br />
PART NO.<br />
QT'Y<br />
SCALE<br />
AS NOTED<br />
FULL SIZE<br />
TRADE<br />
DETECTABLE WARNING SURFACE<br />
MATERIAL<br />
PART NO.<br />
SEE MATERIAL LIST<br />
PROJECT<br />
EMBEDMENT PANEL DETECTABLE<br />
WARNING SURFACE SYSTEM<br />
24" x 36" SOUND ATTENUATING<br />
CURB RAMP TILE (INLINE DOME)<br />
PLANS AND DETAILS<br />
DRAWING NO.<br />
REV. NO.<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
P.O. Box 3<br />
N.Billerica, Ma. 01862<br />
40<br />
www.adatile.com • 800-372-0519
Cast-In-Place Tactile<br />
24”x36” Tile<br />
2.35” Dome Spacing<br />
DETAIL "A"<br />
36.000<br />
PART O.A.<br />
TOP OF PANEL<br />
24.000<br />
PART O.A.<br />
1.200 21.600<br />
9 - EQUAL SPACES<br />
1.200<br />
24.000<br />
PART O.A.<br />
1.200<br />
2.3500<br />
DETAIL "A"<br />
INTERNAL EMBEDMENT<br />
FLANGE @ 3" C/C (SEE PLAN<br />
FOR ORIENTATION)<br />
.450<br />
36.000<br />
PART O.A.<br />
INTERNAL EMBEDMENT<br />
FLANGE @ 3" C/C<br />
BOTTOM OF PANEL<br />
0.625" DIA. HOLE<br />
EMBEDMENT FLANGES<br />
MATERIAL LIST<br />
ITEM DESCRIPTION<br />
PART NO.<br />
SCALE<br />
AS NOTED<br />
FULL SIZE<br />
TRADE<br />
DETECTABLE WARNING SURFACE<br />
PART NO.<br />
SEE MATERIAL LIST<br />
MATERIAL<br />
PROJECT<br />
EMBEDMENT PANEL DETECTABLE<br />
WARNING SURFACE SYSTEM<br />
24" x 36" SOUND ATTENUATING<br />
CURB RAMP TILE (INLINE DOME)<br />
PLANS AND DETAILS<br />
DRAWING NO.<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
P.O. Box 3<br />
N.Billerica, Ma. 01862<br />
QT'Y<br />
REV. NO.<br />
1<br />
2<br />
3<br />
4<br />
2.3500<br />
1.200<br />
9 -9 EQUAL SPACES<br />
.060<br />
0.750<br />
EQUAL SPACES OF .750<br />
.1875<br />
1.160<br />
TYP.<br />
0.188<br />
+2° A/S DRAFT<br />
3.000<br />
6.000<br />
.1875<br />
0.625" DIA. HOLE<br />
EMBEDMENT FLANGES<br />
AS SHOWN IN PLAN<br />
1.375<br />
.250<br />
.0600<br />
DIA.<br />
.900<br />
DIA.<br />
.09000<br />
DIA.<br />
DETAIL "C"<br />
.200<br />
DETAIL "B"<br />
90°<br />
90°<br />
.0450<br />
.0450<br />
DETAIL "B"<br />
DETAIL "C"<br />
.0900<br />
DIA.<br />
WWW.<strong>ADA</strong>TILE.COM<br />
www.adatile.com • 800-372-0519<br />
41
1<br />
2<br />
3<br />
4<br />
Cast-In-Place Tactile<br />
24”x48”<br />
1.67” Dome Spacing<br />
24.000<br />
PART O.A.<br />
1.670<br />
13 - 13 EQUAL SPACES<br />
1.145<br />
DETAIL "B"<br />
1.145<br />
21.710<br />
13 - EQUAL SPACES<br />
1.145<br />
DETAIL "A"<br />
1.434<br />
DETAIL "C"<br />
1.670<br />
27 - 27 EQUAL SPACES<br />
DETAIL "A"<br />
48.000<br />
PART O.A.<br />
TOP OF PANEL<br />
Sect. A-A<br />
1.375<br />
.250<br />
EQUAL SPACES OF .750<br />
0.750<br />
.1875<br />
DETAIL "B"<br />
6.000<br />
3.000<br />
0.188<br />
+2° A/S DRAFT<br />
1.160<br />
TYP.<br />
.060<br />
.200<br />
.450<br />
DIA.<br />
.900<br />
DIA.<br />
FLANGE @ 3" C/C (SEE PLAN<br />
FOR ORIENTATION)<br />
.1875<br />
0.625" DIA. HOLE<br />
EMBEDMENT FLANGES<br />
AS SHOWN IN PLAN<br />
.0600<br />
DETAIL "C"<br />
0.090 0.090<br />
0.045<br />
90°<br />
0.625" DIA. HOLE<br />
EMBEDMENT FLANGES<br />
BOTTOM OF PANEL<br />
INTERNAL EMBEDMENT<br />
FLANGE @ 3" C/C<br />
48.000<br />
PART O.A.<br />
90°<br />
0.045<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
P.O. Box 3<br />
N.Billerica, Ma. 01862<br />
DRAWING NO. REV. NO.<br />
PLANS AND DETAILS<br />
24" x 48" SOUND ATTENUATING<br />
CURB RAMP TILE (INLINE DOME)<br />
EMBEDMENT PANEL DETECTABLE<br />
WARNING SURFACE SYSTEM<br />
PROJECT<br />
MATERIAL<br />
TRADE<br />
DETECTABLE WARNING SURFACE<br />
SEE MATERIAL LIST<br />
PART NO.<br />
SCALE<br />
AS NOTED<br />
FULL SIZE<br />
ITEM<br />
DESCRIPTION<br />
PART NO. QT'Y<br />
MATERIAL LIST<br />
WWW.<strong>ADA</strong>TILE.COM<br />
24.000<br />
PART O.A.<br />
42<br />
www.adatile.com • 800-372-0519
Cast-In-Place Tactile<br />
24”x48” Tile<br />
2.35” Dome Spacing<br />
DETAIL "A"<br />
48.000<br />
PART O.A.<br />
TOP OF PANEL<br />
48.000<br />
PART O.A.<br />
INTERNAL EMBEDMENT<br />
FLANGE @ 3" C/C<br />
BOTTOM OF PANEL<br />
0.625" DIA. HOLE<br />
EMBEDMENT FLANGES<br />
MATERIAL LIST<br />
ITEM DESCRIPTION<br />
PART NO. QT'Y<br />
SCALE<br />
AS NOTED<br />
FULL SIZE<br />
TRADE<br />
DETECTABLE WARNING SURFACE<br />
PART NO.<br />
SEE MATERIAL LIST<br />
MATERIAL<br />
PROJECT<br />
EMBEDMENT PANEL DETECTABLE<br />
WARNING SURFACE SYSTEM<br />
24" x 48" SOUND ATTENUATING<br />
CURB RAMP TILE (INLINE DOME)<br />
PLANS AND DETAILS<br />
DRAWING NO.<br />
REV. NO.<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
P.O. Box 3<br />
N.Billerica, Ma. 01862<br />
1<br />
2<br />
3<br />
4<br />
24.000<br />
PART O.A.<br />
1.200 21.600<br />
9 - EQUAL SPACES<br />
1.200<br />
24.000<br />
PART O.A.<br />
1.200<br />
2.3500<br />
DETAIL "A"<br />
INTERNAL EMBEDMENT<br />
FLANGE @ 3" C/C (SEE PLAN<br />
FOR ORIENTATION)<br />
.450<br />
1.160<br />
TYP.<br />
0.188<br />
+2° A/S DRAFT<br />
6.000<br />
DETAIL "B"<br />
2.3500<br />
9 -9 EQUAL SPACES<br />
1.200<br />
1.375<br />
.060<br />
0.750<br />
EQUAL SPACES OF .750<br />
.1875<br />
DIA.<br />
3.000<br />
.250<br />
.0600<br />
DIA.<br />
.900<br />
90°<br />
90°<br />
.1875<br />
0.625" DIA. HOLE<br />
EMBEDMENT FLANGES<br />
AS SHOWN IN PLAN<br />
.200<br />
.0450<br />
.0450<br />
DETAIL "B"<br />
DETAIL "C"<br />
.0900<br />
DIA.<br />
.09000<br />
DIA.<br />
DETAIL "C"<br />
WWW.<strong>ADA</strong>TILE.COM<br />
www.adatile.com • 800-372-0519<br />
43
1<br />
2<br />
3<br />
4<br />
Cast-In-Place Tactile<br />
24”x60” Tile<br />
1.67” Dome Spacing<br />
24.000<br />
PART O.A.<br />
1.670 1.145<br />
13 - 13 EQUAL SPACES<br />
DETAIL "B"<br />
1.145<br />
21.710 1.145<br />
13 - EQUAL SPACES<br />
DETAIL "A"<br />
1.434<br />
DETAIL "C"<br />
27 - 27 EQUAL SPACES<br />
1.670<br />
DETAIL "A"<br />
1.375<br />
.250<br />
TOP OF PANEL<br />
60.000<br />
PART O.A.<br />
0.750<br />
EQUAL SPACES OF .750<br />
.1875<br />
DETAIL "B"<br />
6.000<br />
3.000<br />
0.188<br />
+2° A/S DRAFT<br />
1.160<br />
TYP.<br />
.060<br />
.200<br />
.450<br />
DIA.<br />
.900<br />
DIA.<br />
FLANGE @ 3" C/C (SEE PLAN<br />
FOR ORIENTATION)<br />
.1875<br />
0.625" DIA. HOLE<br />
EMBEDMENT FLANGES<br />
AS SHOWN IN PLAN<br />
.0600<br />
DETAIL "C"<br />
0.090 0.090<br />
0.045<br />
90°<br />
90°<br />
0.045<br />
0.625" DIA. HOLE<br />
EMBEDMENT FLANGES<br />
BOTTOM OF PANEL<br />
INTERNAL EMBEDMENT<br />
FLANGE @ 3" C/C<br />
60.000<br />
PART O.A.<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
P.O. Box 3<br />
N.Billerica, Ma. 01862<br />
DRAWING NO. REV. NO.<br />
24" x 60" SOUND ATTENUATING<br />
CURB RAMP TILE (INLINE DOME)<br />
PLANS AND DETAILS<br />
EMBEDMENT PANEL DETECTABLE<br />
WARNING SURFACE SYSTEM<br />
PROJECT<br />
MATERIAL<br />
TRADE<br />
DETECTABLE WARNING SURFACE<br />
SEE MATERIAL LIST<br />
PART NO.<br />
AS NOTED<br />
FULL SIZE<br />
SCALE<br />
ITEM<br />
DESCRIPTION<br />
PART NO.<br />
QT'Y<br />
MATERIAL LIST<br />
WWW.<strong>ADA</strong>TILE.COM<br />
24.000<br />
PART O.A.<br />
44<br />
www.adatile.com • 800-372-0519
Cast-In-Place Tactile<br />
24”x60” Tile<br />
2.35” Dome Spacing<br />
1.200 2.3500<br />
DETAIL "A"<br />
0.750<br />
EQUAL SPACES OF .750<br />
.1875<br />
.450<br />
DIA.<br />
6.000<br />
DETAIL "B"<br />
.900<br />
DIA.<br />
90°<br />
90°<br />
.1875<br />
MATERIAL LIST<br />
ITEM DESCRIPTION<br />
PART NO. QT'Y<br />
SCALE<br />
AS NOTED<br />
FULL SIZE<br />
TRADE<br />
DETECTABLE WARNING SURFACE<br />
PART NO.<br />
SEE MATERIAL LIST<br />
MATERIAL<br />
PROJECT<br />
EMBEDMENT PANEL DETECTABLE<br />
WARNING SURFACE SYSTEM<br />
24" x 60" SOUND ATTENUATING<br />
CURB RAMP TILE (INLINE DOME)<br />
PLANS AND DETAILS<br />
DRAWING NO. REV. NO.<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
P.O. Box 3<br />
N.Billerica, Ma. 01862<br />
1<br />
2<br />
3<br />
4<br />
2.3500 1.200<br />
9 -9 EQUAL SPACES<br />
1.375<br />
.250<br />
.200<br />
.0450<br />
.0600<br />
.0450<br />
DETAIL "A"<br />
DETAIL "B"<br />
DETAIL "C"<br />
60.000<br />
PART O.A.<br />
INTERNAL EMBEDMENT<br />
FLANGE @ 3" C/C (SEE PLAN<br />
FOR ORIENTATION)<br />
60.000<br />
PART O.A.<br />
.0900<br />
DIA.<br />
.09000<br />
DIA.<br />
DETAIL "C"<br />
0.625" DIA. HOLE<br />
EMBEDMENT FLANGES<br />
AS SHOWN IN PLAN<br />
24.000<br />
PART O.A.<br />
1.200<br />
21.600<br />
1.200<br />
9 - EQUAL SPACES<br />
24.000<br />
PART O.A.<br />
TOP OF PANEL<br />
1.160<br />
TYP.<br />
0.188<br />
+2° A/S DRAFT<br />
3.000<br />
INTERNAL EMBEDMENT<br />
FLANGE @ 3" C/C<br />
BOTTOM OF PANEL<br />
0.625" DIA. HOLE<br />
EMBEDMENT FLANGES<br />
WWW.<strong>ADA</strong>TILE.COM<br />
.060<br />
www.adatile.com • 800-372-0519<br />
45
1<br />
2<br />
3<br />
4<br />
Cast-In-Place Tactile<br />
36”x48” Tile<br />
1.67” Dome Spacing<br />
1.670<br />
20 -20 EQUAL SPACES<br />
1.300<br />
0.775<br />
DETAIL "B"<br />
1.300<br />
36.000<br />
PART O.A.<br />
33.400<br />
20 - EQUAL SPACES<br />
1.300<br />
DETAIL "A"<br />
DETAIL "B"<br />
DETAIL "A"<br />
6.000<br />
3.000<br />
.1875<br />
.1875<br />
0.625" DIA. HOLE<br />
EMBEDMENT FLANGES<br />
AS SHOWN IN PLAN<br />
0.188<br />
+2° A/S DRAFT<br />
1.160<br />
TYP.<br />
1.375<br />
.060<br />
.250<br />
.200<br />
.0600<br />
0.750<br />
EQUAL SPACES OF .750<br />
.450<br />
DIA.<br />
.900<br />
DIA.<br />
35 -35 EQUAL SPACES<br />
1.670<br />
FLANGE @ 3" C/C (SEE PLAN<br />
FOR ORIENTATION)<br />
DETAIL "C"<br />
Sect. A-A<br />
0.090 0.090<br />
DETAIL "C"<br />
0.625" DIA. HOLE<br />
EMBEDMENT FLANGES<br />
90°<br />
TOP OF PANEL BOTTOM OF PANEL<br />
90°<br />
0.045<br />
0.045<br />
"A" "A"<br />
INTERNAL EMBEDMENT<br />
FLANGE @ 3" C/C<br />
48.000 48.000<br />
PART O.A.<br />
PART O.A.<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
P.O. Box 3<br />
N.Billerica, Ma. 01862<br />
DRAWING NO. REV. NO.<br />
36" x 48" SOUND ATTENUATING<br />
CURB RAMP TILE (INLINE DOME)<br />
PLANS AND DETAILS<br />
EMBEDMENT PANEL DETECTABLE<br />
WARNING SURFACE SYSTEM<br />
PROJECT<br />
MATERIAL<br />
TRADE<br />
DETECTABLE WARNING SURFACE<br />
SEE MATERIAL LIST<br />
PART NO.<br />
AS NOTED<br />
FULL SIZE<br />
SCALE<br />
ITEM<br />
DESCRIPTION<br />
PART NO.<br />
QT'Y<br />
MATERIAL LIST<br />
WWW.<strong>ADA</strong>TILE.COM<br />
36.000<br />
PART O.A.<br />
46<br />
www.adatile.com • 800-372-0519
Cast-In-Place Tactile<br />
36”x60” Tile<br />
1.67” Dome Spacing<br />
DETAIL "A"<br />
DETAIL "B"<br />
60.000<br />
PART O.A.<br />
60.000<br />
PART O.A.<br />
DETAIL "C"<br />
DETAIL "C"<br />
DETAIL "A"<br />
MATERIAL LIST<br />
ITEM DESCRIPTION<br />
PART NO.<br />
QT'Y<br />
SCALE<br />
AS NOTED<br />
FULL SIZE<br />
TRADE<br />
DETECTABLE WARNING SURFACE<br />
PART NO.<br />
SEE MATERIAL LIST<br />
MATERIAL<br />
PROJECT<br />
EMBEDMENT PANEL DETECTABLE<br />
WARNING SURFACE SYSTEM<br />
36" x 60" SOUND ATTENUATING<br />
CURB RAMP TILE (INLINE DOME)<br />
PLANS AND DETAILS<br />
DRAWING NO. REV. NO.<br />
<strong>ADA</strong> SOLUTIONS, INC.<br />
P.O. Box 3<br />
N.Billerica, Ma. 01862<br />
1<br />
2<br />
3<br />
4<br />
36.000<br />
PART O.A.<br />
33.400<br />
20 - EQUAL SPACES<br />
36.000<br />
PART O.A.<br />
INTERNAL EMBEDMENT<br />
FLANGE @ 3" C/C<br />
TOP OF PANEL BOTTOM OF PANEL<br />
0.625" DIA. HOLE<br />
EMBEDMENT FLANGES<br />
0.090 0.090<br />
1.300<br />
1.300<br />
0.045<br />
0.045<br />
0.775<br />
"A" "A"<br />
Sect. A-A<br />
90°<br />
1.670<br />
35 -35 EQUAL SPACES<br />
FLANGE @ 3" C/C (SEE PLAN<br />
FOR ORIENTATION)<br />
0.750<br />
EQUAL SPACES OF .750<br />
.450<br />
DIA.<br />
DIA.<br />
.900<br />
1.160<br />
TYP.<br />
6.000<br />
DETAIL "B"<br />
90°<br />
1.670<br />
20 -20 EQUAL SPACES<br />
1.300<br />
1.375<br />
.060<br />
.250<br />
.200<br />
.0600<br />
35.485<br />
.1875<br />
0.188<br />
+2° A/S DRAFT<br />
3.000<br />
.1875<br />
0.625" DIA. HOLE<br />
EMBEDMENT FLANGES<br />
AS SHOWN IN PLAN<br />
WWW.<strong>ADA</strong>TILE.COM<br />
www.adatile.com • 800-372-0519<br />
47
About the Law<br />
Summary<br />
To view the entire report published by the Access Board go to<br />
REVISED DRAFT GUIDELINES:<br />
http://www.access-board.gov/rowdraft.htm<br />
Accessible Public Rights-Of-Way (11/23/05)<br />
R304 Detectable Warning Surfaces<br />
R304.1 General. Detectable warnings shall consist of a surface of truncated domes aligned in a<br />
square or radial grid pattern and shall comply with R304.<br />
R304.1.1 Dome Size. Truncated domes in a detectable warning surface shall have a base<br />
diameter of 23 mm (0.9 in) minimum to 36 mm (1.4 in) maximum, a top diameter of 50<br />
percent of the base diameter minimum to 65 precent of the base diameter maximum, and a<br />
height of 5 mm (0.2 in).<br />
R304.1.2 Dome Spacing. Truncated domes in a detectable warning surface shall have a<br />
center-to-center spacing of 41 mm (1.6 in) minimum and 61 mm (2.4 in) maximum, and<br />
a base-to-base spacing of 17 mm (.65 in) minimum, measured between the most adjacent<br />
domes.<br />
R304.1.3 Contrast. Detectable warning surfaces shall contrast visually with adjacent gutter,<br />
street or highway, or walkway surface, either light-on-dark, or dark-on-light.<br />
R304.1.4 Size. Detectable warning surfaces shall extend 610 mm (24 in) minimum in the<br />
direction of travel and the full width of the curb ramp (exclusive of flares), the landing, or the<br />
blended transition.<br />
R304.2 Location and Alignment<br />
R304.2.1 Perpendicular Curb Ramps. Where both ends of the bottom grade break<br />
complying with R303.3.4 are 1.5 m (5.0 ft) or less from the back of the curb, the detectable<br />
warning shall be located on the ramp surface at the bottom grade break. Where either end of<br />
the bottom grade break is more than 1.5 m (5.0 ft) from the back of the curb, the<br />
detectable warning shall be located on the lower landing.<br />
R304.2.2 Landings and Blended Transitions. The detectable warning shall be located on<br />
the landing or blended transition at the back of the curb.<br />
R304.2.3 Alignment. The rows of truncated domes in a detectable warning surface shall be<br />
aligned to be perpendicular or radial to the grade break between the ramp, landing, or blended<br />
transition and the street.<br />
48<br />
www.adatile.com • 800-372-0519
THE ONLY COMPLETE DETECTABLE WARNING AND<br />
WAYFINDING SOLUTION FOR THE VISUALLY IMPAIRED<br />
49
www.adatile.com • 800-372-0519 8/11