TECHNICAL DATA - SINGLE<br />

H (kPa)<br />

H (m)<br />

45<br />

0<br />

4,5<br />

2 4 6 8 10 Q IMP gpm<br />

14<br />

40 4<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

P (W)<br />

3,5<br />

3<br />

2,5<br />

2<br />

1,5<br />

1<br />

0,5<br />

0<br />

0<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

0<br />

MODEL CODE<br />

EVOTRON 40/150 SAN 60143366<br />

EVOTRON 60/150 SAN 60143367<br />

EVOTRON 80/150 SAN 60143368<br />

0 2 4 6 8 10 12 Q US gpm<br />

0,5<br />

<strong>DAB</strong> PUMPS reserves the right to make modifications without notice<br />

1,0<br />

1,5<br />

0 2 4 6 8 10 Q IMP gpm<br />

30<br />

0,<br />

5<br />

Min<br />

Max<br />

Min<br />

1,<br />

0<br />

1,<br />

5<br />

2,0<br />

2,<br />

0<br />

2,5<br />

2,<br />

5<br />

0<br />

3,0 Q (m3/h)<br />

0 0.2 0.4 0.6 0.8 Q l/sec<br />

0 10 20 30 40 50 Q l/min<br />

0 2 4 6 8 10 12 Q US gpm<br />

3,<br />

0<br />

H (ft)<br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

Q (m3/h)<br />

0 0.2 0.4 0.6 0.8 Q l/sec<br />

0 10 20 30 40 50 Q l/min<br />

Thanks to the advanced technology employed, the<br />

permanent magnet synchronous motor, and the<br />

frequency converter, the new range of EVOTRON<br />

SAN circulators ensures high efficiency in all applications,<br />

bringing appreciable benefits in terms of energy saving.<br />

That‘s why the entire series of EVOTRON SAN circulators<br />

is included in energy efficiency class A.<br />

The circulator features an electronic device that detects<br />

the changes demanded by the heating system and<br />

automatically adapts circulator performance accordingly,<br />

always ensuring optimal efficiency and minimum energy<br />

consumption.<br />

Straightforward operation and an easy-to-ready control<br />

panel with display that shows the selected setting at each<br />

moment of operation.<br />

Improved and optimized energy consumption overnight<br />

(SMART SLEEP Function).<br />

Supplied with a special connector that enables simple<br />

and quick electrical connections on installation.<br />

CENTRE<br />

DISTANCE<br />

mm<br />

VOLTAGE<br />

50 Hz<br />

ELECTRICAL DATA UNIONS ON REQUEST<br />

P1 RANGE<br />

W<br />

EVOTRON SAN 40 EVOTRON SAN 60<br />

H (kPa)<br />

H (m)<br />

50<br />

40<br />

30<br />

20<br />

10<br />

5<br />

4<br />

3<br />

2<br />

1<br />

0 2 4 6 8 10 12 14 16 Q US gpm<br />

0 2 4 6 8 10 12 14 Q IMP gpm<br />

H<br />

ft<br />

60 6<br />

20<br />

Max<br />

Min<br />

0 0<br />

0 0,5 1,0 1,5 2,0 2,5 3,0 3,5<br />

0<br />

4,0 Q m³h<br />

0 0.2 0.4 0.6 0.8 1.0 Q l/sec<br />

P (W)<br />

In A<br />

EVOTRON SAN<br />

WET ROTOR ELECTRONIC CIRCULATORS<br />

HOT WATER SYSTEMS<br />

Supplied with an insulation housing kit which adds<br />

significantly reducing in heat dispersion.<br />

Operating range: from 0,4 to 4,2 m3/h with head of<br />

up to a 8 mt.<br />

Liquid temperature range: from -10°C a +110°C.<br />

Maximum working pressure: 10 bar (1000 kPa).<br />

Protection rating: IP 44.<br />

Insulation class: F.<br />

Installation: with HORIZONTAL MOTOR SHAFT.<br />

Standard voltage input: single-phase 1x230V/50/60 Hz.<br />

Liquid quality requirements: clean, free of solids<br />

and mineral oils, non-viscous, chemically neutral and<br />

approximating the properties of <strong>water</strong>.<br />

Special versions on request: alternative voltages<br />

and/or frequencies.<br />

BRASS COPPER<br />

150 1x230 V 5 - 27 0,05 - 0,26 ½” F - ¾” M - 1” F ø 22 - ø 28<br />

150 1x230 V 5 - 43 0,05 - 0,60 ½” F - ¾” M - 1” F ø 22 - ø 28<br />

150 1x230 V 5 - 66 0,06 - 0,60 ½” F - ¾” M - 1” F ø 22 - ø 28<br />

MINIMUM<br />

HEAD<br />

PRESSURE<br />

T° + 90°C<br />

m.c.a. 10<br />

T° + 90°C<br />

m.c.a. 10<br />

T° + 90°C<br />

m.c.a. 10<br />

0 10 20 30 40 50 60 Q l/min<br />

0 2 4 6 8 10 12 14 16 Q US gpm<br />

0 2 4 6 8 10 12 14 Q IMP gpm<br />

50<br />

45<br />

40<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

Min<br />

0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 Q m³h<br />

0 0.2 0.4 0.6 0.8 1.0 Q l/sec<br />

0 10 20 30 40 50 60 Q l/min<br />

16<br />

12<br />

8<br />

4<br />

CIRCULATORS AND IN-LINE PUMPS


CIRCULATORS AND IN-LINE PUMPS<br />

EVOTRON SAN 80<br />

H (kPa)<br />

H (m)<br />

80 8<br />

70 7<br />

60 6<br />

50 5<br />

40 4<br />

30 3<br />

20 2<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

Min<br />

0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 Q m³h<br />

0 0.2 0.4 0.6 0.8 1.0 1.2 Q l/sec<br />

0 10 20 30 40 50 60 70 Q l/min<br />

<strong>DAB</strong> PUMPS reserves the right to make modifications without notice<br />

Max<br />

10 1<br />

4<br />

Min<br />

0 0<br />

0<br />

0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 Q m³h<br />

0 0.2 0.4 0.6 0.8 1.0 1.2 Q l/sec<br />

0 10 20 30 40 50 60 70 Q l/min<br />

P (W)<br />

0 2 4 6 8 10 12 14 16 18 Q US gpm<br />

0 2 4 6 8 10 12 14 16 Q IMP gpm<br />

0 2 4 6 8 10 12 14 16 18 Q US gpm<br />

0<br />

80<br />

2 4 6 8 10 12 14 16 Q IMP gpm<br />

DIMENSIONS AND WEIGHTS<br />

L<br />

L1<br />

B1<br />

MODEL L L1 L2 B B1 H H1 F<br />

H<br />

ft<br />

24<br />

20<br />

16<br />

12<br />

8<br />

B<br />

L2<br />

EVOTRON SAN<br />

WET ROTOR ELECTRONIC CIRCULATORS<br />

H<br />

H1<br />

F<br />

PACKAGING DIMENSION<br />

L B H<br />

EVOTRON 40/150 SAN 150 158 79.5 147.5 53 140 85 1”1/2 148 193 217 3.0 120<br />

EVOTRON 60/150 SAN 150 158 79.5 147.5 53 140 85 1”1/2 148 193 217 3.0 120<br />

EVOTRON 80/150 SAN 150 158 79.5 147.5 53 140 85 1”1/2 148 193 217 3.0 120<br />

WEIGHT<br />

KG<br />

Q.TY<br />

x<br />

PALLET