®<br />

GFCI and<br />

Surge<br />

Protected<br />

Power Strip<br />

The GFCI protected<br />

power strip comes<br />

equipped with a three<br />

foot extension cord, six<br />

NEMA 5-15R outlets,<br />

and a lighted on/off<br />

switch. Each unit is<br />

both three mode surge<br />

protected (listed UL<br />

1449) to safeguard the<br />

most sensitive<br />

electronic equipment,<br />

and ground fault<br />

protected to guard<br />

against dangerous<br />

electrical shock<br />

hazards. Manual reset<br />

is required after trip<br />

and power outage to<br />

prevent unmonitored<br />

equipment startup.


FEATURES<br />

Model 14880-PS<br />

Cord Gauge: 14/3 Awg.<br />

NEMA 5 - 15 P & R<br />

Volts/Amps: 120V/15A<br />

Trip Level: 4 - 6 mA<br />

Overcurrent Circuit<br />

Breaker 15A<br />

MOV - 114 joules<br />

U.S. Patent No.<br />

4567456<br />

GFCI<br />

Protected<br />

Quad Box<br />

The Model 14880-QB,<br />

15 Amp quad box is<br />

enclosed in a heavy<br />

impact resistant<br />

polymer case with<br />

spring loaded covers to<br />

protect each pair of<br />

receptacles. A "fast<br />

breaker" is built into<br />

the box for convenient<br />

reset should an<br />

overload condition<br />

occur, preventing<br />

tripping of the supply<br />

side distribution panel.<br />

The GFCI is an integral<br />

part of the male<br />

connector, providing<br />

protection to the entire<br />

cord as well as tools<br />

attached to the four<br />

NEMA 5-15<br />

receptacles in the box.<br />

GFCI color is optional<br />

in high visibility yellow<br />

or black. Available in


2', 6', 25', and 50'<br />

lengths.<br />

These quad boxes are<br />

built to withstand<br />

outdoor - rugged type<br />

construction<br />

applications. Manual<br />

reset is required after<br />

GFCI trip and power<br />

outage to prevent<br />

unmonitored equipment<br />

startup.<br />

FEATURES<br />

Model 14880-QB<br />

Cord Gauge: 12/3 Awg.<br />

NEMA 5 - 15 P & R<br />

Volts/Amps: 120V/15A<br />

Trip Level: 4 - 6 mA<br />

U.S. Patent No.<br />

4567456<br />

GFCI<br />

Protected<br />

Quad Box<br />

The Model<br />

25080L-QB, 20 Amp<br />

quad box is enclosed in<br />

a heavy impact<br />

resistant polymer case<br />

with spring loaded<br />

covers to protect each<br />

pair of receptacles. A<br />

"fast breaker" is built<br />

into the box for<br />

convenient reset should<br />

an overload condition<br />

occur, preventing<br />

tripping of the supply<br />

side distribution panel.<br />

The GFCI is located at<br />

the power end of units,<br />

providing protection to<br />

the cord as well as tools<br />

attached to the four<br />

NEMA 5-20<br />

receptacles in the box.<br />

Two of these<br />

receptacles are T -<br />

slotted, to allow both<br />

15 and 20 ampere rated<br />

tools, with either<br />

NEMA 5-15 or NEMA


5-20 plugs. Available<br />

in 2', 6', 25', and 50'<br />

lengths.<br />

These quad boxes are<br />

built to withstand<br />

outdoor - rugged type<br />

construction<br />

applications. Manual<br />

reset is required after<br />

GFCI trip and power<br />

outage to prevent<br />

unmonitored equipment<br />

startup.<br />

FEATURES<br />

Model 25080L-QB<br />

Cord Gauge: 12/3 Awg.<br />

NEMA 5 - 20 P & R<br />

Volts/Amps: 120V/20A<br />

Trip Level: 4 - 6 mA<br />

U.S. Patent No.<br />

4567456<br />

GFCI<br />

Protected<br />

Tri-Cord<br />

The Model 14880-TC,<br />

GFCI protected tri-cord<br />

has three NEMA 5-15<br />

receptacles at the end of<br />

a heavy duty molded<br />

T-head. The GFCI is an<br />

integral part of the male<br />

plug providing<br />

protection for the extra<br />

heavy duty cord itself<br />

and three attached tools.<br />

This cord set is supplied<br />

with 12 gauge cord and<br />

is ideal for outdoor -<br />

rugged construction<br />

type environments.<br />

Available in 2', 6', 25',<br />

50' and 99' lengths.<br />

Manual reset is required<br />

after GFCI trip and<br />

power outage to prevent<br />

unmonitored equipment<br />

startup.<br />

FEATURES


Model 14880-TC<br />

Cord Gauge: 12/3 Awg.<br />

NEMA 5 - 15 P & R<br />

Volts/Amps: 120V/15A<br />

Trip Level: 4 - 6 mA<br />

U.S. Patent No.<br />

4567456<br />

Inline GFCI<br />

Protected<br />

Tri-Cord<br />

The Model 26020-TC,<br />

GFCI protected tri-cord<br />

has three NEMA 5-15<br />

receptacles at the end of<br />

a heavy duty molded<br />

T-head. The inline<br />

GFCI is an integral part<br />

built into of the male<br />

plug providing<br />

protection for the extra<br />

heavy duty cord itself<br />

and three attached tools.<br />

This cord set is supplied<br />

with 12 gauge cord and<br />

is ideal for outdoor -<br />

rugged construction<br />

type environments.<br />

Available in 2', 6', 25',<br />

50' and 99' lengths.<br />

Manual reset is required<br />

after GFCI trip and<br />

power outage to prevent<br />

unmonitored equipment<br />

startup.<br />

FEATURES<br />

Model 26020-TC<br />

Cord Gauge: 12/3 Awg.<br />

NEMA 5 - 15 P & R<br />

Volts/Amps: 120V/15A<br />

Trip Level: 4 - 6 mA<br />

U.S. Patent No.<br />

4567456


GFCI<br />

Protected<br />

Trouble Light<br />

The Model 14880-TL,<br />

GFCI protected trouble<br />

light is surrounded by<br />

an all metal housing<br />

and includes one extra<br />

NEMA 5-15<br />

convenience receptacle<br />

at the light end. The<br />

GFCI is an integral part<br />

of the male plug<br />

providing protection for<br />

a 25 foot extension<br />

cord, tools or<br />

appliances plugged into<br />

the extra outlet and the<br />

light itself. The trouble<br />

light is right for all<br />

industrial uses where a<br />

light is necessary and<br />

electrical safety is a key<br />

concern. Manual reset<br />

is required after GFCI<br />

trip and power outage<br />

to prevent unmonitored<br />

equipment startup.<br />

FEATURES<br />

Model 14880-TL<br />

Cord Gauge: 16/3 Awg.<br />

NEMA 5 - 15 P & R<br />

Volts/Amps: 120V/13A<br />

Trip Level: 4 - 6 mA<br />

U.S. Patent No.<br />

4567456