TRC/MILLS TALBOT COMPANY 14880TC-2-502 - Transcat
TRC/MILLS TALBOT COMPANY 14880TC-2-502 - Transcat
TRC/MILLS TALBOT COMPANY 14880TC-2-502 - Transcat
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
®<br />
GFCI and<br />
Surge<br />
Protected<br />
Power Strip<br />
The GFCI protected<br />
power strip comes<br />
equipped with a three<br />
foot extension cord, six<br />
NEMA 5-15R outlets,<br />
and a lighted on/off<br />
switch. Each unit is<br />
both three mode surge<br />
protected (listed UL<br />
1449) to safeguard the<br />
most sensitive<br />
electronic equipment,<br />
and ground fault<br />
protected to guard<br />
against dangerous<br />
electrical shock<br />
hazards. Manual reset<br />
is required after trip<br />
and power outage to<br />
prevent unmonitored<br />
equipment startup.
FEATURES<br />
Model 14880-PS<br />
Cord Gauge: 14/3 Awg.<br />
NEMA 5 - 15 P & R<br />
Volts/Amps: 120V/15A<br />
Trip Level: 4 - 6 mA<br />
Overcurrent Circuit<br />
Breaker 15A<br />
MOV - 114 joules<br />
U.S. Patent No.<br />
4567456<br />
GFCI<br />
Protected<br />
Quad Box<br />
The Model 14880-QB,<br />
15 Amp quad box is<br />
enclosed in a heavy<br />
impact resistant<br />
polymer case with<br />
spring loaded covers to<br />
protect each pair of<br />
receptacles. A "fast<br />
breaker" is built into<br />
the box for convenient<br />
reset should an<br />
overload condition<br />
occur, preventing<br />
tripping of the supply<br />
side distribution panel.<br />
The GFCI is an integral<br />
part of the male<br />
connector, providing<br />
protection to the entire<br />
cord as well as tools<br />
attached to the four<br />
NEMA 5-15<br />
receptacles in the box.<br />
GFCI color is optional<br />
in high visibility yellow<br />
or black. Available in
2', 6', 25', and 50'<br />
lengths.<br />
These quad boxes are<br />
built to withstand<br />
outdoor - rugged type<br />
construction<br />
applications. Manual<br />
reset is required after<br />
GFCI trip and power<br />
outage to prevent<br />
unmonitored equipment<br />
startup.<br />
FEATURES<br />
Model 14880-QB<br />
Cord Gauge: 12/3 Awg.<br />
NEMA 5 - 15 P & R<br />
Volts/Amps: 120V/15A<br />
Trip Level: 4 - 6 mA<br />
U.S. Patent No.<br />
4567456<br />
GFCI<br />
Protected<br />
Quad Box<br />
The Model<br />
25080L-QB, 20 Amp<br />
quad box is enclosed in<br />
a heavy impact<br />
resistant polymer case<br />
with spring loaded<br />
covers to protect each<br />
pair of receptacles. A<br />
"fast breaker" is built<br />
into the box for<br />
convenient reset should<br />
an overload condition<br />
occur, preventing<br />
tripping of the supply<br />
side distribution panel.<br />
The GFCI is located at<br />
the power end of units,<br />
providing protection to<br />
the cord as well as tools<br />
attached to the four<br />
NEMA 5-20<br />
receptacles in the box.<br />
Two of these<br />
receptacles are T -<br />
slotted, to allow both<br />
15 and 20 ampere rated<br />
tools, with either<br />
NEMA 5-15 or NEMA
5-20 plugs. Available<br />
in 2', 6', 25', and 50'<br />
lengths.<br />
These quad boxes are<br />
built to withstand<br />
outdoor - rugged type<br />
construction<br />
applications. Manual<br />
reset is required after<br />
GFCI trip and power<br />
outage to prevent<br />
unmonitored equipment<br />
startup.<br />
FEATURES<br />
Model 25080L-QB<br />
Cord Gauge: 12/3 Awg.<br />
NEMA 5 - 20 P & R<br />
Volts/Amps: 120V/20A<br />
Trip Level: 4 - 6 mA<br />
U.S. Patent No.<br />
4567456<br />
GFCI<br />
Protected<br />
Tri-Cord<br />
The Model 14880-TC,<br />
GFCI protected tri-cord<br />
has three NEMA 5-15<br />
receptacles at the end of<br />
a heavy duty molded<br />
T-head. The GFCI is an<br />
integral part of the male<br />
plug providing<br />
protection for the extra<br />
heavy duty cord itself<br />
and three attached tools.<br />
This cord set is supplied<br />
with 12 gauge cord and<br />
is ideal for outdoor -<br />
rugged construction<br />
type environments.<br />
Available in 2', 6', 25',<br />
50' and 99' lengths.<br />
Manual reset is required<br />
after GFCI trip and<br />
power outage to prevent<br />
unmonitored equipment<br />
startup.<br />
FEATURES
Model 14880-TC<br />
Cord Gauge: 12/3 Awg.<br />
NEMA 5 - 15 P & R<br />
Volts/Amps: 120V/15A<br />
Trip Level: 4 - 6 mA<br />
U.S. Patent No.<br />
4567456<br />
Inline GFCI<br />
Protected<br />
Tri-Cord<br />
The Model 26020-TC,<br />
GFCI protected tri-cord<br />
has three NEMA 5-15<br />
receptacles at the end of<br />
a heavy duty molded<br />
T-head. The inline<br />
GFCI is an integral part<br />
built into of the male<br />
plug providing<br />
protection for the extra<br />
heavy duty cord itself<br />
and three attached tools.<br />
This cord set is supplied<br />
with 12 gauge cord and<br />
is ideal for outdoor -<br />
rugged construction<br />
type environments.<br />
Available in 2', 6', 25',<br />
50' and 99' lengths.<br />
Manual reset is required<br />
after GFCI trip and<br />
power outage to prevent<br />
unmonitored equipment<br />
startup.<br />
FEATURES<br />
Model 26020-TC<br />
Cord Gauge: 12/3 Awg.<br />
NEMA 5 - 15 P & R<br />
Volts/Amps: 120V/15A<br />
Trip Level: 4 - 6 mA<br />
U.S. Patent No.<br />
4567456
GFCI<br />
Protected<br />
Trouble Light<br />
The Model 14880-TL,<br />
GFCI protected trouble<br />
light is surrounded by<br />
an all metal housing<br />
and includes one extra<br />
NEMA 5-15<br />
convenience receptacle<br />
at the light end. The<br />
GFCI is an integral part<br />
of the male plug<br />
providing protection for<br />
a 25 foot extension<br />
cord, tools or<br />
appliances plugged into<br />
the extra outlet and the<br />
light itself. The trouble<br />
light is right for all<br />
industrial uses where a<br />
light is necessary and<br />
electrical safety is a key<br />
concern. Manual reset<br />
is required after GFCI<br />
trip and power outage<br />
to prevent unmonitored<br />
equipment startup.<br />
FEATURES<br />
Model 14880-TL<br />
Cord Gauge: 16/3 Awg.<br />
NEMA 5 - 15 P & R<br />
Volts/Amps: 120V/13A<br />
Trip Level: 4 - 6 mA<br />
U.S. Patent No.<br />
4567456