Performance<br />
Data<br />
(25 Ton)<br />
High Efficiency<br />
Table PD-30 — Evaporator Fan Performance — 25 Ton — TC*301C — Standard Refrigeraton System<br />
External Static Pressure (Inches of Water)<br />
.10 .20 .30 .40 .50 .60 .70 .80 .90 1.00<br />
CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP<br />
7.5 HP Standard Motor & Field Supplied Extra Low Static Drive (1) 7.5 HP Standard Motor & Low Static Drive Accessory<br />
5000* — — — — — — — — — — 576 1.56 606 1.71 635 1.88 663 2.05 690 2.22<br />
6500* — — — — 576 2.11 601 2.27 625 2.43 649 2.59 674 2.78 698 2.97 722 3.18 746 3.38<br />
7000* — — 579 2.32 608 2.54 633 2.73 656 2.89 678 3.06 700 3.25 723 3.44 745 3.65 768 3.87<br />
7500* 582 2.59 611 2.78 640 3.02 665 3.24 687 3.43 708 3.61 729 3.79 749 3.98 770 4.19 792 4.41<br />
8000 616 3.07 645 3.31 672 3.56 696 3.80 719 4.02 739 4.22 759 4.41 778 4.60 797 4.81 817 5.03<br />
8500 650 3.66 678 3.90 704 4.16 728 4.43 750 4.68 771 4.90 790 5.10 808 5.31 826 5.52 844 5.74<br />
9000 685 4.31 712 4.56 737 4.83 760 5.12 782 5.39 802 5.65 821 5.88 839 6.09 856 6.30 873 6.53<br />
9500 721 5.04 746 5.30 770 5.58 792 5.88 814 6.18 834 6.46 853 6.72 870 6.96 887 7.18 903 7.41<br />
10000 756 5.85 780 6.12 803 6.41 825 6.72 846 7.04 866 7.35 884 7.64 902 7.90 918 8.14 934 8.38<br />
10500 791 6.74 814 7.03 836 7.33 858 7.64 878 7.98 898 8.31 916 8.62 — — — — — —<br />
11000 827 7.71 849 8.02 870 8.33 891 8.63 — — — — — — — — — — — —<br />
7.5 HP Standard Motor & Drive<br />
7.5 HP Standard Motor & Higher Static Drive Accessory<br />
Table PD-30 — Evaporator Fan Performance — 25 Ton — TC*301C — Continued<br />
External Static Pressure (Inches of Water)<br />
1.10 1.20 1.30 1.40 1.50<br />
CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP<br />
7.5 HP Standard Motor & Drive<br />
5000* 716 2.41 741 2.60 765 2.80 789 3.00 812 3.20<br />
6500* 769 3.59 792 3.80 814 4.01 836 4.22 857 4.44<br />
7000* 790 4.09 812 4.31 833 4.53 854 4.76 875 4.99<br />
7500* 813 4.65 833 4.88 854 5.12 874 5.36 894 5.59<br />
8000 837 5.26 857 5.51 876 5.76 896 6.01 915 6.26<br />
8500 863 5.97 881 6.21 900 6.46 919 6.73 937 6.99<br />
9000 890 6.76 908 7.00 925 7.25 943 7.52 961 7.79<br />
9500 919 7.64 936 7.88 952 8.13 969 8.40 985 8.67<br />
10000 949 8.62 — — — — — — — —<br />
10500 — — — — — — — — — —<br />
11000 — — — — — — — — — —<br />
7.5 HP Standard Motor & High Static Drive Accessory<br />
For Standard Evaporator Fan Speed (RPM), reference Table PD-31.<br />
For Standard Motor & High Static Drive Accessory Fan Speed (RPM),<br />
reference Table PD-32.<br />
For Standard Motor & Low Static Drive Accessory Fan Speed (RPM),<br />
reference Table PD-34.<br />
Fan motor heat (MBH) = 3.15 x Fan BHP<br />
*Unit applications below 8000 CFM<br />
• <strong>Electric</strong> heaters restricted on applications below 8000<br />
CFM.<br />
• Dehumidification (Hot Gas Reheat) or TXV <strong>with</strong> Frostat<br />
and Crankcase <strong>Heat</strong>ers are required on applications<br />
below 8000 CFM.<br />
Notes:<br />
Data includes pressure drop due to wet coils and filters.<br />
No accessories or options are included in pressure drop data.<br />
Refer to Table PD-35 to determine add’l static pressure drop due to<br />
other options/accessories.<br />
Factory supplied motors, in commercial<br />
equipment, are definite purpose motors,<br />
specifically designed and tested to operate<br />
reliably and continuously at all cataloged<br />
conditions. Using the full horsepower range<br />
of our fan motors as shown in our tabular<br />
data will not result in nuisance tripping or<br />
premature motor failure. Our product’s<br />
warranty will not be affected.<br />
*Indicates both downflow and horizontal units.<br />
44 RT-PRC002-EN