Chapter 8 Constant-volume AHU with warm-up, pre-cool, and communications<br />

Table 24: Modified constant-volume AHU variables data definition (continued)<br />

Variable Name Notes<br />

Local binary variables Supply Fan Failure Sourced from a program<br />

Exhaust Fan Failure<br />

Sourced from a program<br />

Sensor Failure<br />

Sourced from a program<br />

Duct Humidity Limit Sourced from a program<br />

Low OA Temp Alarm Sourced from a program<br />

Fan Failure Reset<br />

Sourced from operator display and a program<br />

Alarm Reset<br />

Sourced from operator display and a program<br />

Manual Reset Alarm Sourced from a program<br />

Auto Reset Alarm<br />

Sourced from a program<br />

Thumbwheel SP Enable Sourced from operator display<br />

Heat/Cool Mode<br />

Sourced from a program<br />

OK to Economize<br />

Sourced from a program<br />

Humidify<br />

Sourced from a program<br />

Dehumidify<br />

Sourced from a program<br />

Night Heat/Cool<br />

Sourced from a program<br />

Warm-Up<br />

Sourced from a program<br />

Pre-Cool<br />

Sourced from a program<br />

<strong>Tracer</strong> Summit analog variables Not Used<br />

Local analog variables Space Temp SP (OD) Setpoint sourced from the operator display<br />

Eff Occ Cool SP<br />

Sourced from a program<br />

Eff Occ Heat SP<br />

Sourced from a program<br />

Effective Cool SP<br />

Sourced from a program<br />

Effective Heat SP<br />

Sourced from a program<br />

Economizer Changeover SP Sourced from the operator display<br />

Discharge Air SP<br />

Sourced from a program<br />

Low OA Temp SP<br />

Setpoint sourced from the operator display<br />

Mixed Air Temp SP<br />

Setpoint sourced from the operator display<br />

Dehumidification SP Setpoint sourced from the operator display<br />

Humidification SP<br />

Setpoint sourced from the operator display<br />

Ex Fan OA Damper SP Setpoint sourced from the operator display<br />

Ex Fan OA Damper Dbd Setpoint sourced from the operator display<br />

Before you write the program, configure these inputs, outputs, and variables<br />

in your <strong>Tracer</strong> MP580/581 controller. Because you are programming<br />

a constant-volume air-handling unit, set the controller to use the Space<br />

Comfort Controller (SCC) profile. For more information about configuring<br />

the controller, including setting it to use the SCC profile, see the <strong>Tracer</strong><br />

MP580/581 Programmable Controller <strong>Programming</strong> guide<br />

(CNT-SVP01A-EN). The SCC profile provides the configuration data<br />

listed in Table 25 on page 197, and the network variable inputs and out-<br />