4. Reassemble conveyor drive chain cover and then<br />

reassemble the bottom cover to the drive chain cover.<br />

Install both upper end plugs.<br />

SECTION 4<br />

MAINTENANCE<br />

III. MAINTENANCE - EVERY 3 MONTHS<br />

WARNING<br />

Shut OFF all electrical power and lock/tag out the<br />

switch before attempting maintenance work.<br />

Shut OFF gas supply to oven.<br />

NOTE: It is recommended that the 3-month maintenance<br />

be performed by an authorized Middleby Marshall<br />

technician.<br />

A. Cleaning the Blower/Fan Motor<br />

To gain access to the blower/fan motor, open the control<br />

cabinet door by removing the three screws. Clean the<br />

motor, burner blower motor, the conveyor drive motor and<br />

the surrounding area, using either compressed air or CO 2<br />

.<br />

Thoroughly blow out the motor compartment and vents<br />

inside the motor (Figure 4-38). Failure to do this can cause<br />

premature failure of blower fan motor.<br />

Figure 4-35.<br />

CAUTION<br />

Not cleaning the blower/fan motor properly can<br />

cause premature failure.<br />

Figure 4-36.<br />

39