4. Reassemble conveyor drive chain cover and then<br />
reassemble the bottom cover to the drive chain cover.<br />
Install both upper end plugs.<br />
SECTION 4<br />
MAINTENANCE<br />
III. MAINTENANCE - EVERY 3 MONTHS<br />
WARNING<br />
Shut OFF all electrical power and lock/tag out the<br />
switch before attempting maintenance work.<br />
Shut OFF gas supply to oven.<br />
NOTE: It is recommended that the 3-month maintenance<br />
be performed by an authorized Middleby Marshall<br />
technician.<br />
A. Cleaning the Blower/Fan Motor<br />
To gain access to the blower/fan motor, open the control<br />
cabinet door by removing the three screws. Clean the<br />
motor, burner blower motor, the conveyor drive motor and<br />
the surrounding area, using either compressed air or CO 2<br />
.<br />
Thoroughly blow out the motor compartment and vents<br />
inside the motor (Figure 4-38). Failure to do this can cause<br />
premature failure of blower fan motor.<br />
Figure 4-35.<br />
CAUTION<br />
Not cleaning the blower/fan motor properly can<br />
cause premature failure.<br />
Figure 4-36.<br />