26.09.2014 Views

Asbestos - Rules of Abatement - Oregon OSHA

Asbestos - Rules of Abatement - Oregon OSHA

Asbestos - Rules of Abatement - Oregon OSHA

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Provision Class I Class II Class III Class IV<br />

Training Equivalent to <strong>Asbestos</strong><br />

Hazard Emergency<br />

Response Act<br />

(AHERA) worker training<br />

See (k)(9)(iii) & (k)(9)(iv) Equivalent to AHERA<br />

operations and<br />

maintenance course<br />

Equivalent to AHERA<br />

awareness training<br />

Decontamination<br />

procedures<br />

Full decon unit required<br />

if > 25 linear feet or 10<br />

square feet <strong>of</strong> thermal<br />

insulation or surfacing<br />

materials removal:<br />

• Connected shower/<br />

clean room required<br />

• Vacuum, change,<br />

shower elsewhere<br />

• Detailed procedures<br />

Lunch area required<br />

if < 25 linear feet or 10<br />

square feet <strong>of</strong> thermal<br />

insulation or surfacing<br />

materials removal or<br />

>PEL or no NEA:<br />

• Equipment room/area<br />

required<br />

If >PEL or no NEA:<br />

• Equipment room/area<br />

required<br />

• Drop cloths required<br />

• Area must<br />

accommodate<br />

cleanup<br />

• Must decontaminate<br />

all personal protective<br />

equipment<br />

• Must enter regulated<br />

area through<br />

equipment room/<br />

decon area<br />

No smoking in work<br />

area<br />

If >PEL or no NEA:<br />

• Equipment room/area<br />

required<br />

• Drop cloths required<br />

• Area must<br />

accommodate<br />

cleanup<br />

• Must decontaminate<br />

all personal protective<br />

equipment<br />

• Must enter regulated<br />

area through<br />

equipment room/<br />

decon area<br />

If NEA, must vacuum<br />

No smoking in work<br />

area<br />

If >PEL or no NEA:<br />

• Equipment room/area<br />

required<br />

• Drop cloths required<br />

• Area must<br />

accommodate<br />

cleanup<br />

• Must decontaminate<br />

all personal protective<br />

equipment<br />

• Must enter regulated<br />

area through<br />

equipment room/<br />

decon area<br />

No smoking in work<br />

area<br />

Class I continues<br />

on page 36<br />

DEQ/LRAPA<br />

Friable<br />

Training required by a<br />

DEQ accredited trainer<br />

<strong>OSHA</strong> requirements<br />

apply<br />

DEQ/LRAPA<br />

Nonfriable<br />

<strong>OSHA</strong> competent<br />

person requirements<br />

apply<br />

<strong>OSHA</strong> requirements<br />

apply<br />

35