26.09.2014 Views

Parallel Bipolar - Lumenis Aesthetic

Parallel Bipolar - Lumenis Aesthetic

Parallel Bipolar - Lumenis Aesthetic

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Skin Renewal<br />

with FACES technology<br />

Selective Radiothermoplasty<br />

The first radio frequency device for skin<br />

tightening and wrinkle reduction to use radio<br />

frequency energy in a truly targeted and<br />

selective manner<br />

<strong>Parallel</strong> <strong>Bipolar</strong><br />

FACES –Functional Aspiration Controlled<br />

Electrothermal Stimulation<br />

Aluma's unique FACES technology combines <strong>Bipolar</strong> RF with<br />

vacuum to target heat safely and virtually painlessly deep in the<br />

dermis for effective wrinkle treatment and skin tightening.<br />

FACES uses vacuum to:<br />

●<br />

●<br />

Position the skin for optimum targeting of collagen-rich<br />

dermal tissue so RF flows in a straight path through the<br />

dermal tissue.<br />

Ensure 100% contact with electrodes to eliminate the<br />

risk of arcing.<br />

FACES vacuum<br />

assisted parallel<br />

bipolar radio<br />

frequency delivery<br />

concentrates heat<br />

deep in the dermis<br />

A coupling medium reduces the impedence of the epidermis<br />

allowing the RF energy to pass through it without creating heat.<br />

As the RF meets the impedance in the dermis, heat is<br />

generated. The result: safe and effective deep dermal heating<br />

with little or no discomfort.<br />

<strong>Parallel</strong> Electrodes<br />

<strong>Parallel</strong> bipolar electrodes placed<br />

in egg whites demonstrate heat<br />

generated centrally between<br />

electrodes resulting in deeper,<br />

targeted opacification


About Radio Frequency<br />

Radio frequency energy always takes the shortest path from source to ground. As it meets impedance in the tissue,<br />

heat is generated. For effective skin tightening and treatment of wrinkles and fine lines, heat must be created deep in<br />

the dermis without injuring the epidermis. RF systems come in three basic configurations: monopolar, flush bipolar, and<br />

Aluma's parallel bipolar design.<br />

Other RF Systems<br />

Monopolar Systems:<br />

In monopolar systems, a grounding<br />

pad is used. While the majority of<br />

the energy is converted to heat at<br />

the surface of the skin, much flows<br />

through the body to the grounding<br />

pad. These types of systems<br />

require cooling and can be painful<br />

to patients.<br />

<strong>Bipolar</strong> Systems with Flush Electrode Placement<br />

As RF follows the shortest path from source to ground, it flows primarily<br />

across the epidermis depositing heat superficially and having little impact<br />

on dermal collagen. Another disadvantage of flush bipolar systems is the<br />

potential for arcing and epidermal burns if complete electrode contact<br />

with tissue is compromised.<br />

Current flows<br />

through body to<br />

grounding pad<br />

Current flow<br />

localized — only<br />

between<br />

electrodes<br />

Flush bipolar RF<br />

generates heat<br />

in upper layers<br />

of skin<br />

Flush Electrodes<br />

Flush bipolar electrodes<br />

placed in egg whites<br />

demonstrate superficial<br />

heat generation resulting<br />

in shallow opacification<br />

<strong>Lumenis</strong> Inc.<br />

2400 Condensa Street<br />

Santa Clara, CA 95051 USA<br />

Tel 408 764 3000<br />

877 586 3647<br />

Fax 408 764 3999<br />

800 505 1133<br />

<strong>Lumenis</strong> (GERMANY) GmbH<br />

Dreieich-Dreieichenhain,<br />

Germany<br />

Tel + 49 6103 8335 0<br />

Fax + 49 6103 8335 300<br />

<strong>Lumenis</strong> (FRANCE) SARL<br />

Orsay, France<br />

Tel + 33 1 69 33 14 20<br />

Fax + 33 1 60 19 57 23<br />

<strong>Lumenis</strong> (ITALY) Srl.<br />

Formello (RM), Italy<br />

Tel + 39 06 90 75 230<br />

Fax + 39 06 90 75 269<br />

<strong>Lumenis</strong> (UK) Ltd.<br />

London, UK<br />

Tel + 44 20 8324 4200<br />

Fax + 44 20 8324 4222<br />

<strong>Lumenis</strong> (JAPAN) Co. Ltd.<br />

Tokyo, Japan<br />

Tel + 81 3 5789 8300<br />

Fax + 81 3 5789 8310<br />

<strong>Lumenis</strong> (CHINA) Ltd.<br />

Beijing, China<br />

Tel + 86 10 6510 2620<br />

Fax + 86 10 6510 2621<br />

<strong>Lumenis</strong> (HK) Ltd.<br />

Hong Kong<br />

Tel + 852 2174 2800<br />

Fax + 852 2722 5151<br />

internet: www.lumenis.com<br />

email: information@lumenis.com<br />

©2006, the <strong>Lumenis</strong> group of Companies. All rights reserved. <strong>Lumenis</strong>, its logo, Aluma and FACES are trademarks of the <strong>Lumenis</strong> group of companies.<br />

Printed in the U.S.A.<br />

PB-005897 Rev. A

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!