Hour Meter<br />

The hour meter is located on the control console next to<br />

the operator seat.<br />

Testing<br />

1. Disconnect wire harness connector from hour meter.<br />

2. Connect the positive (+) terminal of a 12 VDC source<br />

to the positive (+) terminal of the hour meter.<br />

3. Connect the negative (--) terminal of the voltage<br />

source to the other terminal of the hour meter.<br />

4. The hour meter should move a 1/10 of an hour in six<br />

(6) minutes.<br />

1<br />

2<br />

Figure 27<br />

1. Positive (+) terminal 2. Negative ( -) terminal<br />

5. Disconnect voltage source from the hour meter. Reconnect<br />

harness connector to hour meter.<br />

Audio Alarm<br />

The audio alarm for low engine oil pressure or high engine<br />

coolant temperature is attached to the control console<br />

next to the operator seat.<br />

Testing<br />

1. Disconnect wire harness connector from alarm.<br />

IMPORTANT: Make sure to observe polarity on the<br />

alarm terminals when testing. Damage to the alarm<br />

may result from an improper connection.<br />

2. Correctly connect 12VDC source to the alarm terminals<br />

(Fig. 28).<br />

3. Alarm should sound. Remove voltage source from<br />

the alarm.<br />

4. Reconnect harness connector to alarm.<br />

1 3<br />

2<br />

1. Top view<br />

2. Bottom view<br />

Figure 28<br />

3. Positive (+) terminal<br />

4. Negative ( -) terminal<br />

4<br />

Electrical<br />

System<br />

Groundsmaster 4100--D Page 5 - 19 Electrical System