Counterbalance Manifold Service<br />

35 to 40 ft -lb<br />

(47to54N-m)<br />

2<br />

4<br />

35 to 40 ft -lb<br />

(47to54N-m)<br />

3<br />

2<br />

35 to 40 ft -lb<br />

(47to54N-m)<br />

5<br />

3<br />

1<br />

UP<br />

FRONT<br />

1. Manifold body<br />

2. Pilot valve<br />

Figure 95<br />

3. Seal kit<br />

4. Relief valve (counterbalance)<br />

5. Seal kit<br />

NOTE: The ports on the manifold are marked for easy<br />

identification of components. Example: C1 is the connection<br />

port from the LH deck lift cylinder and CHG is the<br />

charge circuit connection (See Hydraulic Schematic in<br />

Chapter 9 -- Foldout Drawings to identify the function of<br />

the hydraulic lines and cartridge valves at each port).<br />

Counterbalance Manifold Service (Fig. 95)<br />

For cartridge valve service procedures, see 4WD Manifold<br />

Service in this section. Refer to Figure 95 for counterbalance<br />

manifold cartridge valve installation torque.<br />