5. Remove lock nuts, flat washers, cap screws, and<br />

coupler spacers that secure rubber coupling to pump<br />

hub.<br />

6. Remove four (4) flange head screws and flange nuts<br />

that secure pump to pump mount bracket.<br />

7. Remove pump from machine.<br />

8. If needed, loosen set screws in pump hub. Pull hub<br />

from pump shaft. Locate and remove key from pump<br />

shaft. Remove set screws from pump hub. Clean<br />

threads of set screws and hub.<br />

9. Secure pump to mounting bracket by tightening<br />

flange head screws and flange nuts.<br />

10.Position front and rear guard plates to pump mount<br />

bracket. Install and tighten flange head screw and<br />

flange nut to guard plates. Install flange nuts to secure<br />

guard plates to pump mount bracket.<br />

11.Install pressure and suction hoses to correct barb fittings<br />

(Fig. 7). Secure hoses with hose clamps.<br />

9. If needed, remove pressure dampener, tee fitting<br />

(pressure), and elbow fitting (pressure) from pump outlet<br />

(Fig. 8).<br />

10.If needed, remove suction dampener and tee fitting<br />

(suction) from pump inlet (Fig. 8).<br />

Installation (Fig. 6)<br />

NOTE: Coat all spray system O--rings with vegetable<br />

oil before installation to reduce the chance of damage<br />

during assembly.<br />

2<br />

1<br />

1. Apply PTFE tape to threads of removed tee fitting<br />

(pressure), elbow fitting (pressure), and tee fitting (suction).<br />

Position new O--rings and gaskets on suction and<br />

pressure fittings that were removed during disassembly.<br />

2. If removed, install tee fitting (suction) and suction<br />

dampener to pump inlet. Orientate tee toward rear of<br />

machine (Fig. 8).<br />

1. Pressure hose 2. Suction hose<br />

10<br />

8<br />

9<br />

Figure 7<br />

6<br />

7<br />

6<br />

3. If removed, install elbow fitting (pressure), tee fitting<br />

(pressure), and pressure dampener to pump outlet.<br />

Orientate elbow toward rear of machine (Fig. 8).<br />

4. If pump hub was removed, apply antiseize lubricant<br />

to pump shaft. Install key in shaft and slide pump hub<br />

onto shaft.<br />

11<br />

12<br />

13<br />

14<br />

15<br />

5<br />

4<br />

3<br />

2<br />

1<br />

Spray<br />

System<br />

5. Position pump on pump mounting bracket and install<br />

flange head screws and flange nuts to pump and mounting<br />

bracket. Leave fasteners loose.<br />

17<br />

16<br />

9<br />

6. Place coupling spacers into rubber coupling. Install<br />

cap screws, flat washers, and lock nuts to secure rubber<br />

coupling to pump hub. Make sure that cap screw<br />

threads extend through lock nut.<br />

7. If pump hub was removed, apply Loctite #242 (or<br />

equivalent) to threads of pump hub set screws. Install<br />

set screws into pump hub to secure hub to pump shaft.<br />

8. Turn pump shaft by hand and position pump on<br />

mounting bracket to best align the coupling assembly<br />

between the pump shaft and the hydraulic motor shaft.<br />

1. Spray pump<br />

2. Pressure hose (1”)<br />

3. Hose clamp<br />

4. Hose barb<br />

5. Nut<br />

6. Gasket<br />

7. Tee fitting (pressure)<br />

8. Elbow fitting (pressure)<br />

9. O -ring<br />

Figure 8<br />

10. Pressure dampener<br />

11. Suction hose (1 1/2”)<br />

12. Hose clamp<br />

13. Nut<br />

14. Seal<br />

15. Tee fitting (suction)<br />

16. Suction dampener<br />

17. Hose barb<br />