Service and Repairs<br />

Suction Dampener<br />

The suction dampener is mounted to the suction line at<br />

the spray pump (Fig. 2) and is used to dampen suction<br />

pulses to smooth suction flow. During normal pump operation,<br />

the suction dampener diaphragm will move.<br />

IMPORTANT: Make sure to neutralize and remove<br />

chemicals from pump and hoses before loosening<br />

and removing spray system components.<br />

A damaged suction dampener diaphragm will allow a<br />

suction leak and will cause improper pump operation. If<br />

the diaphragm is damaged, remove diaphragm from<br />

dampener housing and replace it (Fig. 3).<br />

2<br />

3<br />

1<br />

Figure 2<br />

1. Spray pump 3. Suction hose<br />

2. Suction dampener<br />

1<br />

4<br />

2<br />

3<br />

Figure 3<br />

1. Spray pump 3. Dampener housing<br />

2. O–ring 4. Diaphragm<br />

Spray System Page 6 – 8 <strong>Multi</strong> <strong>Pro</strong> <strong>5700</strong>–D