Fuel Pump<br />

The fuel pump is attached to the frame just outboard of<br />

the fuel injection pump (Fig. 40).<br />

DANGER<br />

7. Wipe up any spilled fuel.<br />

8. Reconnect electrical connector to the fuel stop solenoid.<br />

9. Bleed fuel system (see Operator’s Manual).<br />

Because diesel fuel is highly flammable, use caution<br />

when handling it. Do not smoke while testing<br />

the fuel pump. Do not test fuel pump while engine<br />

is hot. Make sure that there is adequate ventilation<br />

when testing. Always wipe up any spilled<br />

fuel before starting the engine.<br />

Operational Test<br />

1. Disconnect electrical connector from the fuel stop<br />

solenoid to prevent the engine from firing (see Fuel Stop<br />

Solenoid in this section).<br />

2. Disconnect pump fuel discharge hose from the fuel<br />

filter.<br />

3. Make sure fuel hoses attached to the fuel pump are<br />

free of obstructions.<br />

4. Place pump discharge fuel hose into a large, graduated<br />

cylinder sufficient enough to collect 1 liter (33.8 fluid<br />

ounces).<br />

IMPORTANT: When testing the fuel pump, DO NOT<br />

turn ignition switch to START.<br />

Note: Machines that are equipped with a Biodiesel<br />

Conversion Kit will have the same fuel pump as machines<br />

with serial numbers above 280000000.<br />

Figure 40<br />

1. Fuel pump 2. Fuel discharge hose<br />

Fuel Pump Specifications<br />

1 2<br />

Fuel pump specifications for machines with serial numbers<br />

below 270999999 are as follows:<br />

Pump Capacity<br />

Pressure<br />

Current Draw<br />

23.5 fl oz/min (700 ml/min)<br />

3.3 PSI (22.8 kPa)<br />

0.9 amp<br />

Fuel pump specifications for machines with serial numbers<br />

above 280000000 are as follows:<br />

Electrical<br />

System<br />

5. Collect fuel in the graduated cylinder by turning ignition<br />

switch to the RUN position. Allow pump to run for<br />

time listed below, then return switch to OFF.<br />

A. For machines with serial numbers below<br />

270999999, the amount of fuel collected in the graduated<br />

cylinder should be approximately 11.8 fl oz<br />

(350 ml) after thirty (30) seconds.<br />

B. For machines with serial numbers above<br />

280000000, the amount of fuel collected in the graduated<br />

cylinder should be approximately 16 fl oz (475<br />

ml) after fifteen (15) seconds.<br />

6. Replace fuel pump as necessary. Install fuel hose to<br />

the fuel filter.<br />

Pump Capacity<br />

Pressure<br />

Current Draw<br />

64 fl oz/min (1.9 liters/min)<br />

7 PSI (48.3 kPa)<br />

2.0 amp<br />

<strong>Multi</strong> <strong>Pro</strong> <strong>5700</strong>--D Page 5 - 25 Rev. C<br />