Spray Pump, Agitation and Boom Control Switches<br />

The spray pump (on/off), agitation (on/off) and boom<br />

(on/off) control switches are located on the spray control<br />

console (Fig. 27).<br />

Testing<br />

3<br />

2<br />

1. Make sure ignition switch is off. Remove console<br />

panel, locate switch and unplug machine wire harness<br />

connector from switch.<br />

4<br />

6<br />

2. The switch terminals are marked as shown in Figure<br />

28. In the ON position, continuity should exist between<br />

terminals 2 and 3 and also between terminals 5 and 6.<br />

In the OFF position, continuity should exist between terminals<br />

1 and 2 and also between terminals 4 and 5.<br />

5<br />

1<br />

3. Terminals 7 (–) and 8 (+) are used for the indicator Figure 27<br />

light in the switch. The light should be illuminated when 1. Spray control console 4. RH boom switch<br />

the switch is in the ON position. 2. Agitation switch 5. Center boom switch<br />

3. Spray pump switch 6. LH boom switch<br />

4. Reconnect the harness connector to the switch after<br />

testing.<br />

7 4 5 6<br />

8 1 2 3<br />

BACK OF SWITCH<br />

Figure 28<br />

Electrical<br />

System<br />

<strong>Multi</strong> <strong>Pro</strong> <strong>5700</strong>–D Page 5 – 17 Electrical System