GDC Specifications<br />

Feature Using Stand-Alone Controller Using SitePro Central Software<br />

Number of wire paths 2 4<br />

Maximum stations per wire path 100 800<br />

Maximum stations per system 200 3200<br />

Simultaneous solenoids per wire path 20 100<br />

GDC System<br />

Maximum distance from central to<br />

2.7 miles 2.7 miles<br />

decoder (using 14 gauge wire)<br />

Maximum distance from decoder to<br />

400 ft 400 ft<br />

sprinkler (using 14 gauge wire)<br />

Solenoids per output 2 2<br />

Wireless remote control N/A HHRI<br />

Maximum number of programs 10 Unlimited<br />

Mapping capabilities N/A T.Map<br />

Stations per decoder 1, 2 or 4 1, 2 or 4<br />

Pump station integration No Yes<br />

Sensors Rain, pressure Rain, pressure<br />

Decoder wiring 14 gauge 14 gauge<br />

Solenoids DCLS-P DCLS-P<br />

Sensor decoder available Pulse or switch Pulse or switch<br />

Decoder identification Unique 6-character address Unique 6-character address<br />

Operating temperature 32°F to 140°F (0°C to 60°C) 32°F to 140°F (0°C to 60°C)<br />

Storage temperature -22°F to 212°F (-30°C to 100°C) -22°F to 212°F (-30°C to 100°C)<br />

Gateway output voltage 38 V ac max 38 V ac max<br />

Gateway output Power 98VA max 98VA max<br />

Cabinet type<br />

Non-corrosive lockable wall mount,<br />

indoor/outdoor installation<br />

Non-corrosive lockable wall mount,<br />

indoor/outdoor installation<br />

Input power supply<br />

100 V ac, 50/60 Hz<br />

120 V ac, 50/60 Hz<br />

220–240 V ac, 50/60 Hz<br />

100 V ac, 50/60 Hz<br />

120 V ac, 50/60 Hz<br />

220–240 V ac, 50/60 Hz<br />

Specifying Information<br />

DEC-SA-200<br />

Type Communication Sta. Count<br />

DEC SA 200<br />

DEC—Decoder SA—Stand-alone 200—200<br />

Stations<br />

Specifying Information—<br />

Decoder<br />

DEC-ISP-XXX<br />

Type<br />

DEC<br />

DEC-ISP—Decoder<br />

Configuration<br />

XX<br />

1—1-station<br />

2—2-station<br />

4—4-station<br />

SEN—Sensor<br />

Decoder<br />

Example: A 2-station GDC Decoder<br />

would be specified as: DEC-ISP-2<br />

Specifying Information—GDC System<br />

SP-0X-X-0X<br />

Type Computer Hardware Service Field Hardware<br />

SP 0X X 0X<br />

SP—SitePro<br />

1—Standard Computer<br />

4—Premium Computer<br />

1—1-year NSN 8—GDC System<br />

5—5-years NSN<br />

Example: A SitePro Central standard computer with 1-year of NSN<br />

and GDC System field hardware would be specified as: SP-1-01-08<br />