16.09.2014 Views

Golf Irrigation Catalog - Toro

Golf Irrigation Catalog - Toro

Golf Irrigation Catalog - Toro

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Features<br />

• Operates as stand-alone controller<br />

(great for new construction)<br />

or under full management of a<br />

central controller<br />

• Advanced modular design,<br />

12 to 24 stations in four-station<br />

increments<br />

• User-friendly interface for<br />

simple-operation<br />

• Maximum lightning protection<br />

with EHCs<br />

• Global or independent<br />

program-adjust<br />

• Eight independent programs<br />

available—up to four may<br />

run simultaneously<br />

- 14-day CALendar or<br />

1- to 30-day INTerval scheduling<br />

by program<br />

- 0 to 3 repeats per program<br />

- 0- to 59-minute soak time per<br />

program<br />

- Up to 12 starts per program<br />

• Station run times from<br />

one minute to eight hours<br />

and 59 minutes<br />

• 24 V ac actuation<br />

• Selective pause/cancel/resume<br />

control<br />

• Water manually with On/Off<br />

switches<br />

• Percent adjust by program<br />

(10 to 250%)<br />

• Syringe %, allows 10 to 100%<br />

operating adjustment<br />

• Up to two non-irrigation (switch)<br />

programs available with SitePro ®<br />

central software<br />

• Non-volatile memory saves<br />

program data for up to 10 years<br />

without power<br />

• Manual operation by program<br />

(normal or syringe), independent<br />

station or multiple stations<br />

(up to six)<br />

Network LTC ® with<br />

Electric-hydraulic<br />

Converters<br />

12 to 24 stations in four-station increments<br />

Operates as stand-alone or with central controller<br />

Maximum lightning protection<br />

Specifications<br />

Electrical<br />

Input power:<br />

• 115/230 V ac, 50/60 Hz<br />

• 0.15 amps @ 115 V ac, 60 Hz (no load)<br />

• 1.09 amps @ 115 V ac, 60 Hz (maximum load)<br />

• 0.15 amps @ 230 V ac, 50 Hz (no load)<br />

• 0.59 amps @ 230 V ac, 50 Hz (maximum load)<br />

UL listed, CSA certified, TUV licensed<br />

Mechanical<br />

Dimensions:<br />

• 16” W x 39” H x 16” D (41 W x 99 H x 41cm D)<br />

Specifying Information—Network LTC Satellite w/EHC<br />

LTC-XX-X-1-0X<br />

Model Configuration Cabinet Output Surge Protection Options<br />

LTC XX X 1 0 X<br />

LTC—Network LTC<br />

Satellite<br />

12—12 Stations<br />

24—24 Stations<br />

P—Plastic<br />

1—Normally Open<br />

Hydraulic<br />

0—Standard<br />

3—Stand-alone<br />

4—LTC Modem<br />

5—VT Modem<br />

Expansion Module*<br />

MOD-S4—4-station Surge-protected Module Providing 24 V ac Electric Output<br />

EHC Base Expansion Kits**<br />

MOD4-WT-01—4-station Normally Open Hydraulic Expansion Module w/Terminal Strip<br />

EHC Add-On Expansion Kits***<br />

MOD1-LT-01—1-station Normally Open Hydraulic Expansion Module w/o Terminal Strip<br />

MOD4-LT-01—5- to 8-station Normally Open Hydraulic Expansion Module w/o Terminal Strip<br />

Example: When specifying a 20-station Network LTC Satellite with a plastic cabinet,<br />

normally open hydraulic output, standard surge protection and LTC modem, you would specify:<br />

LTC12P1-04, MOD-S4 (qty. 2), MOD4-LT-01 and MOD4-WT-01<br />

* 24 stations maximum.<br />

** Each Network LTC satellite is pre-wired to accommodate 16 EHC stations.<br />

*** To use the add-on expansion kit, you must have a base expansion kit with terminal strip installed.<br />

69<br />