18<br />

● Low Cost<br />

● Form A, B<br />

or Latching<br />

Contacts<br />

● Excellent RF<br />

Characteristics<br />

● High Isolation<br />

Voltage<br />

● Excellent<br />

Lifetime<br />

Characteristics<br />

● Reed switch<br />

connections<br />

via PCB<br />

‘through-hole’<br />

or flying lead<br />

4 Series<br />

Screened. 3.5kV, 3.5A<br />

Developed for RF applications (in the band 1-30MHz) the 4 series <strong>reed</strong> relay offers<br />

a highly fexible, low cost package available with form A (NO),form B (NC) and<br />

latching (bistable) contact configurations as well as switch connections for either<br />

PCB or flying lead mounting. The use of Crydom’s vacuum <strong>reed</strong> switches with<br />

rhodium contacts means that high isolation voltages, low contact resistance and<br />

long operating lifetimes are achieved. Additionally, RF screening is available to<br />

further enhance RF performance for more demanding applications.<br />

CONTACT UNITS CONDITIONS FORM A FORM B LATCHING<br />

Contact Material Rhodium Rhodium Rhodium<br />

Isolation across contacts kV DC or AC peak 3 3 3.5<br />

Max. carry current A DC or AC rms* 3.5 3.5 1.5<br />

Max. switching power W 10 10 10<br />

Max. switching voltage V DC or AC peak 20 20 20<br />

Max. switching current A DC or AC peak 0.5 0.5 0.5<br />

Capacitance across contacts pF coil/screen grounded


°<br />

19<br />

MECHANICAL<br />

<strong>radio</strong> <strong>frequency</strong><br />

<strong>reed</strong> <strong>relays</strong>


20<br />

● New fully<br />

screened<br />

miniature relay<br />

● Excellent RF<br />

Characteristics<br />

● Ambient<br />

operating<br />

temperatures<br />

up to 100°C<br />

● Carry current up<br />

to 4 amps (RMS)<br />

● Reed Switch<br />

connection<br />

via PCB<br />

‘through-hole’<br />

or flying lead<br />

5 Series<br />

Fully Screened. 3.5kV, 4A<br />

Developed closely with RF design Engineers in the <strong>radio</strong> communications<br />

industry, this new fully screened <strong>reed</strong> relay series offers the ultimate in low RF<br />

loss and current carrying capability. The relay coil section is totally enclosed in a<br />

copper screen, resulting in lower self-heating and ESR. Together with Crydom’s<br />

vacuum <strong>reed</strong> switches, benefits include higher carry currents for a given<br />

<strong>frequency</strong> and ambient temperature. Peak RF isolation voltages up to 3.5kV are<br />

achieved by clever coil design, maximising pin spacing. Switch connections are<br />

offered for either PCB or Flying Lead mounting.<br />

CONTACT UNITS CONDITIONS FORM A FORM B LATCHING<br />

Contact Material Rhodium Rhodium Rhodium<br />

Isolation across contacts kV DC or AC peak 3 3 3.5<br />

Max. carry current A DC or AC rms* 4 4 1.5<br />

Max. switching power W 10 10 10<br />

Max. switching voltage V DC or AC peak 20 20 20<br />

Max. switching current A DC or AC peak 0.5 0.5 0.5<br />

Capacitance across contacts pF coil/screen grounded


65°C<br />

85°C<br />

100°C<br />

21<br />

MECHANICAL<br />

" "<br />

(0.2")<br />

10.16<br />

(0.4")<br />

25.4<br />

(1.0")<br />

<strong>radio</strong> <strong>frequency</strong><br />

<strong>reed</strong> <strong>relays</strong>


SIP Series<br />

Reed Relay<br />

The SIP series <strong>reed</strong> <strong>relays</strong> are available in both voltage and current driven (line sense) versions. The SIP<br />

range requires only half the PCB area of the DIP series.<br />

The construction of the SIP series corresponds to the creepage and clearance requirements of the new<br />

European Standards; EN60950.<br />

CONTACT CONTACT DIAGRAM NOMINAL COIL MUST OPERATE MUST RELEASE MAXIMUM MAXIMUM RATED<br />

FORM TYPE VOLTAGE RESISTANCE VOLTAGE VOLTAGE VOLTAGE VOLTAGE POWER<br />

+/-10% MAXIMUM MINIMUM 20°C 60°C<br />

COIL VDC Ohm VDC VDC VDC VDC mW<br />

01 5 500 3.5 0.75 23 14 50<br />

1A 02 L/M/D/Q 12 1000 8.4 1.8 33 20 144<br />

02<br />

05 L/M/D/Q 15 2000 10.5 2.2 47 29 112<br />

03L 24 2000 16.8 3.6 47 29 288<br />

1A 02 01L M 5H 1000 3.5 0.75 33 20 25<br />

02LM 12H 2000 8.4 1.8 47 29 72<br />

Please note that the 5V types with contact 05 have a reduced coil resistance of 2OO.<br />

CONTACT CONTACT DIAGRAM NOMINAL COIL MUST OPERATE MUST RELEASE MAXIMUM MAXIMUM INDUCTANCE<br />

FORM TYPE VOLTAGE RESISTANCE VOLTAGE VOLTAGE VOLTAGE VOLTAGE AT 1KhZ<br />

+/-10% MAXIMUM MINIMUM 20°C 60°C +/-20%<br />

Line Sense Ohm VDC VDC VDC VDC mH<br />

Relay<br />

1A 11 01M 15 15 5 240 149 3,45<br />

Other coils on request<br />

• Designed to EN60950<br />

• High Sensitivity Coils<br />

up to 2,000 Ohms @<br />

12V<br />

CONFIGURATION<br />

01<br />

PART NUMBERING SYSTEM - SIP SERIES<br />

02 03<br />

• Line Sense Relay<br />

Option available<br />

• Magnetic and Diode<br />

option available<br />

• Insulation Voltage up<br />

to 4.25kVdc<br />

• Variants UL approved<br />

S 12 - 1A 02 01 - L H<br />

Series<br />

Dual in line package (SIP)<br />

Coil Voltage<br />

5V, 12V, 24V<br />

Contact Form<br />

1A<br />

Contact Type<br />

02, 05, 11<br />

SIP-2000UK<br />

High Resistance Version<br />

Options<br />

L : without diode<br />

M : with magnetic screen<br />

01D : Diode on pins 3 & 5,<br />

no magnetic screen<br />

01Q : diode pins 3 & 5,<br />

with magnetic screen<br />

02D : diode pins 2 & 6,<br />

no magnetic screen<br />

02Q : diode pins 2 & 6,<br />

with magnetic screen<br />

Configuration<br />

01, 02, 03<br />

Crydom Magnetics Ltd<br />

7 Cobham Road<br />

Ferndown Industrial Estate<br />

Wimborne<br />

Dorset BH21 7PE<br />

Tel: +44 (0) 1202 897969<br />

Fax: +44 (0) 1202 891918<br />

magnetics@crydom.com<br />

www.crydom.co.uk


SIP Series<br />

Reed Relay<br />

CONTACT CONDITIONS UNITS 02 05 11<br />

Contact Form A/dry A/d ry A/d ry<br />

Rated Power max W 15 10 5<br />

Switching Voltage max VDC 200 500 90<br />

Switching Current max A 1,0 0,5 0,5<br />

Carry Current A 1,25 1,0 1,0<br />

Contact resistance max mohms 150 200 200<br />

Breakdown Voltage (contact/contact) min VDC 250 1'500 100<br />

Operate time incl. bounce ms 0,5 0,5 0,5<br />

Release time ms 0,1 0,1 0,1<br />

RELAY CONDITIONS UNITS<br />

Shock at 11ms max g 35<br />

Vibration at 50-500Hz max g 20<br />

OperatingTemperature °C -20/+70<br />

Storage Temperature °C -35/+95<br />

Isolation coil/contact min kV 1,5 DC (4,25 DC /3,0 AC at diagram 03L)<br />

Insulation coil/contact min Gohms 100<br />

Life expectancy<br />

Dependent upon load, consult sales office<br />

Solder time/temperature max 10 sec,/260°C<br />

Washability<br />

Fully Sealed<br />

Data at 140% of the nominal voltage and 20°C. Other switches against inquiry.<br />

MECHANICAL<br />

19.80* max<br />

(0.78")<br />

7.80** max<br />

(0.31")<br />

5.08 max<br />

(0.20")<br />

19.60* max<br />

(0.78")<br />

3.20 min<br />

(0.126")<br />

4.60 max<br />

(0.18")<br />

5.00**** max<br />

(0.196“)<br />

15.24<br />

(0.60")<br />

0.60 max<br />

(0.023")<br />

5.08<br />

(0.20")<br />

0.25<br />

(0.10")<br />

3.5±0.20<br />

(0.14")(0.008")<br />

2.54<br />

(0.10")<br />

15.24<br />

(0.60")<br />

0.60 max<br />

(0.023")<br />

3.5±0.20<br />

(0.14") (0.008")<br />

0.25<br />

(0.10")<br />

Dimension with *(20.50 max) ** (8.30 max) ***(6.80 max) **** (6.00 max)<br />

Magnetic screen (0.807") (0.33") (0.27") (0.24")<br />

Every effort has been made to ensure that the descriptions and specifications quoted are correct, however, no liability can be<br />

accepted for any errors or omissions in this data. The detail specifications are subject to change without prior notice.<br />

Crydom Magnetics Ltd<br />

7 Cobham Road<br />

Ferndown Industrial Estate<br />

Wimborne<br />

Dorset BH21 7PE<br />

Tel: +44 (0) 1202 897969<br />

Fax: +44 (0) 1202 891918<br />

magnetics@crydom.com<br />

www.crydom.co.uk


DIP Series<br />

Reed Relay<br />

Moulded Dual-in Line package <strong>reed</strong> <strong>relays</strong> designed for ATE, telecom, alarm and other general purpose<br />

systems. Coils with optional diodes and/or screens and mercury wetted contacts are available. Please<br />

contacts sales office for details.<br />

CONTACT CONTACT DIAGRAM NOMINAL COIL MUST OPERATE MUST RELEASE MAXIMUM MAXIMUM RATED<br />

FORM TYPE VOLTAGE RESISTANCE VOLTAGE VOLTAGE VOLTAGE VOLTAGE POWER<br />

+/-10% MAXIMUM MINIMUM 20°C 60°C<br />

COIL VDC Ohm voc VDC VDC VDC mw<br />

01 01L/D/A 5 500 3.5 0.75 23.0 14.0 50<br />

1A 02 02L/D 12 1000 8.4 1.8 33.0 20.0 144<br />

05 15 2000 10.5 2.2 48.0 30.0 113<br />

Flat package 24 2000 16.8 3.6 48.0 30.0 288<br />

1A 01 02 01L H 5 1000 3.5 0.75 33.0 20.0 25<br />

Flat package High ohms type 12 2000 8.4 1.8 48.0 30.0 72<br />

01 03L 5 500 3.5 0.75 6.5 6.5 50<br />

1B 02 03D 12 1000 8.4 1.8 15.6 15.6 144<br />

05 15 2000 10.5 2.2 19.5 19.5 113<br />

High package 24 2000 16.8 3.6 31.2 30.0 288<br />

01 04L 5 200 3.5 0.75 14.0 9.0 125<br />

2A 02 04D 12 500 8.4 1.8 23.0 14.0 288<br />

05 15 2000 10.5 2.2 48.0 30.0 113<br />

High package 24 2000 16.8 3.6 48.0 30.0 288<br />

Flat package 05L 5 200 3.5 0.75 14.0 9.0 125<br />

1C 20 12 500 8.4 1.8 23.0 14.0 288<br />

15 2000 10.5 2.2 48.0 30.0 113<br />

High package 05D 24 2000 16.8 3.6 48.0 30.0 288<br />

Please note that the types with contact 05 form 1A and 1B have a reduced coil resistance of 2OOohms and 120ohms respectively.<br />

MECHANICAL<br />

High package<br />

Flat package<br />

• Low Profile Package<br />

• Standard and Non<br />

Standard Pin<br />

Configurations<br />

available<br />

• IC-pin compatible<br />

• Interface Directly<br />

with TTL-logic<br />

• Up to 4.25 KVDC<br />

Insulation available in<br />

02L configuration<br />

• Variants UL approved<br />

19.30 max<br />

(0.76")<br />

2.54<br />

(0.10")<br />

15.24<br />

(0.60")<br />

3.20<br />

(0.126")<br />

0.50<br />

(0.02")<br />

0.25 x 0.50<br />

(0.01") (0.02")<br />

7.00 max<br />

(0.27")<br />

7.50 max<br />

(0.30")<br />

15°<br />

7.62<br />

(0.30")<br />

5.70<br />

(0.22“)<br />

19.30 max<br />

(0.76")<br />

2.80<br />

(0.11“)<br />

2.54<br />

3.20<br />

(0.10")<br />

(0.126“) 15.24<br />

(0.60")<br />

7.62<br />

(0.30")<br />

(0.08“)<br />

2<br />

6.40 max<br />

(0.25“)<br />

5.10 max<br />

(0.20")<br />

15°<br />

0.25 x 0.50<br />

(0.01") (0.02")<br />

PART NUMBERING SYSTEM - DIP SERIES<br />

D 12 - 1A 01 01 - L H<br />

Series<br />

Dual in line package (DIP)<br />

Coil Voltage<br />

5V, 12V, 24V<br />

Contact Form<br />

1A, 1B, 2A, 1C<br />

Contact Type<br />

01, 02, 05, 20<br />

DIP-2000UK<br />

High Resistance Version<br />

Options<br />

L : without diode<br />

D : Diode on pins 2 & 6<br />

A : Diode on pins 6 & 9<br />

Configuration<br />

01, 02, 03, 04, 05<br />

Crydom Magnetics Ltd<br />

7 Cobham Road<br />

Ferndown Industrial Estate<br />

Wimborne<br />

Dorset BH21 7PE<br />

Tel: +44 (0) 1202 897969<br />

Fax: +44 (0) 1202 891918<br />

magnetics@crydom.com<br />

www.crydom.co.uk


DIP Series<br />

Reed Relay<br />

CONTACT CONDITIONS UNITS 01 02 05 20<br />

Contact Form A/dry A/dry A/d ry C/d ry<br />

Rated Power max W 10 15 10 3<br />

Switching Voltage max VDC 200 200 500 175<br />

Switching Current max A 0,5 1,0 0,5 0,25<br />

Carry Current A 1,0 1,25 1,0 1,2<br />

Contact resistance max 0Q 150 150 200 150<br />

Breakdown Voltage (contact/contact) min VDC 250 250 1'500 200<br />

Operate time incl. bounce MS 0,5 0,5 0,5 0,7<br />

Release time MS 0,1 0,1 0,1 1,0<br />

RELAY CONDITIONS UNITS<br />

Shock at 11ms max G 35<br />

Vibration at 50-500Hz max 920<br />

OperatingTemperature oc 20+70<br />

Storage Temperature oc 35 +95<br />

Isolation coil/contact min kV 1,5 DC (4,25 DC /3,0 AC diagram 02L)<br />

Insulation coil/contact min GQ 100<br />

Life expectancy<br />

Dependent upon load, consult sales office<br />

Solder time/temperature max 10 sec,/260'C<br />

Washability<br />

Fully Sealed<br />

Data at 140% of the nominal voltage and 20'C. Other switches against inquiry.<br />

CONFIGURATION<br />

01 02<br />

03 04 05<br />

14<br />

8<br />

14<br />

8<br />

14<br />

8<br />

14<br />

8<br />

14<br />

8<br />

1<br />

7<br />

2<br />

6<br />

1<br />

7<br />

1<br />

7<br />

1<br />

7<br />

Every effort has been made to ensure that the descriptions and specifications quoted are correct, however, no<br />

liability can be accepted for any errors or omissions in this data. The detail specifications are subject to change<br />

without prior notice.<br />

Crydom Magnetics Ltd<br />

7 Cobham Road<br />

Ferndown Industrial Estate<br />

Wimborne<br />

Dorset BH21 7PE<br />

Tel: +44 (0) 1202 897969<br />

Fax: +44 (0) 1202 891918<br />

magnetics@crydom.com<br />

www.crydom.co.uk


22<br />

● 15kV Isolation<br />

● Low Contact<br />

Resistance<br />

● High Power<br />

Switching<br />

● PCB or Panel<br />

Mount<br />

● Flying Lead &<br />

Solder Turret<br />

Options<br />

● Excellent AC<br />

Characteristics<br />

D Series<br />

15kV, 50W<br />

Capable of withstanding voltages up to 15kV, the D-series High Voltage Reed<br />

Relay is suitable for high reliability applications such as cardiac defibrillators,<br />

test equipment and high voltage power supplies. Two contact materials are<br />

available for low contact resistance or power switching applications.<br />

Standard coil voltages of 5, 12 and 24 volts are available with form A and B<br />

contact configurations.<br />

The D-series, range is now available with a new panel mounting option via nylon<br />

studs, as well as a choice of electrical connection methods (solder turret tag and<br />

flying lead) complementing the standard PCB ‘through-hole’ device. Choose the<br />

most appropriate device for your application using the part numbering system<br />

below.<br />

CONTACT UNITS CONDITIONS 10KV FORM A 10KV FORM B 15KV FORM A<br />

Contact material Rhodium Tungsten Rhodium Tungsten Tungsten<br />

Isolation across contacts kV DC or AC peak 10 10 10 10 15<br />

Max. switching power W 50 50 50 50 50<br />

Max. switching voltage V DC or AC peak 1000 7000 1000 7000 10000<br />

Max. switching current A DC or AC peak 3 2 3 2 2<br />

Capacitance across<br />

contacts pF coil/screen grounded


MECHANICAL<br />

23<br />

-<br />

+<br />

T<br />

T71210P)<br />

high voltage<br />

<strong>reed</strong> <strong>relays</strong>


8<br />

● Up to 8kVDC<br />

Isolation<br />

● 6A Carry<br />

Current<br />

(up to 30MHz)<br />

● Excellent RF<br />

Performance<br />

● Ideal for<br />

Antenna Tuning<br />

Units<br />

● Form A/B<br />

Contact<br />

Configuration<br />

● Customising<br />

Facility<br />

FRD12000 Series<br />

Screened. 8kV, 6A<br />

The FRD12000 series was one of Crydom’s first RF <strong>reed</strong> relay designs. With 8kV<br />

(DC) withstand voltage and 6A (30MHz) carry current capability, the FRD12000<br />

series has satisfied countless HF <strong>radio</strong> system specifications over the years,<br />

finding applications in commercial maritime (GMDSS) equipment and military HF<br />

<strong>radio</strong> units worldwide.<br />

CONTACT UNITS CONDITIONS FRD12015 FRD12021 FRD12014 FRD12049<br />

Action (form A, B or Latching) A B A B<br />

Switching Voltage V DC max 20 20 20 20<br />

Switching Current A DC max 1 1 1 1<br />

Carry Current A RMS max 6 6 6 6<br />

Isolation kV DC max 8 8 8 8<br />

Capacitance pF coil/screen gnd 0.4 0.6 0.4 0.6<br />

Lifetime operations dry switching 10 9 10 9 10 9 10 9<br />

Contact Resistance mOhms maximum (typical) 50 (15) 50 (15) 50 (15) 50 (15)<br />

Insulation Resistance Ohms minimum (typical) 10 10 (10 13 ) 10 10 (10 13 ) 10 10 (10 13 ) 10 10 (10 13 )<br />

ESR at 4.5A, 30MHz mOhms typical 100 150 100 150<br />

COIL at 20°C<br />

Nominal Working Voltage VDC 24 12 12 24<br />

Must Operate VDC max 15 8 8 14<br />

Must Release VDC min 2 2 2 4<br />

Nominal Resistance ohms +/10% 1000 380 340 1500<br />

RF Screening Part - Part -<br />

RF Screening Connection pin position 1 & 4 1 & 4<br />

Coil Connections pin position 2 & 3 2 & 3 2 & 3 2 & 3<br />

RELAY<br />

Operate time (including bounce) ms 2 3 3 3<br />

Release time ms 1 2 1 2<br />

Isolation contact to all<br />

other terminals kV DC max 10 10 10 10<br />

Isolation coil to screen kV DC max 0.5 N/A 0.5 N/A<br />

Capacitance contact to<br />

all other terminals pF contacts open 2.0 2.5 2.0 2.5<br />

CONTACT US NOW<br />

UNITED KINGDOM<br />

CRYDOM<br />

T +44 (0)1202 897969<br />

F +44 (0)1202 891918<br />

E magnetics@crydom.com<br />

W www.crydom.co.uk<br />

USA<br />

CRYDOM<br />

T +1 858 715 7200<br />

F +1 858 715 7280<br />

E sales@crydom.com<br />

W www.crydom.com<br />

ENVIRONMENTAL<br />

Storage temperature range °C -55 to +125<br />

Operating temperature range °C Limited current* -40 to +85<br />

Shock g 11ms 1/2 sine pk 100<br />

Bump g 6ms 1/2 sine pk 40<br />

Vibration g 10- 500Hz 10<br />

*see graphical data


Available with either 12 or 24V coils, in both form A and B contact<br />

configurations, this proven design is fully approved to MIL standards of<br />

bump, shock and vibration and features one of Crydom’s in-house<br />

manufactured, high vacuum <strong>reed</strong> switches for unsurpassed RF<br />

performance and reliability.<br />

Offering a cost effective alternative to vacuum ceramic <strong>relays</strong>, the<br />

FRD12000 Series RF Reed Relay has a greater lifetime, imperative for<br />

<strong>frequency</strong> hopping systems. As well as HF <strong>radio</strong>s, the FRD12000 Series<br />

has also found applications in electromedical, sonar and test equipment,<br />

which require high isolation and inherent reliability.<br />

9<br />

y<br />

MECHANICAL<br />

<strong>radio</strong> <strong>frequency</strong><br />

<strong>reed</strong> <strong>relays</strong>


14<br />

● Up to 3KV<br />

Isolation<br />

● 5A Carry<br />

Current<br />

(up to 30MHz)<br />

● Excellent RF<br />

Characteristics<br />

● Designed for<br />

HF Applications<br />

● Compact<br />

Package on<br />

0.1" Pin Pitch<br />

● Full<br />

Customising<br />

Facility<br />

FRS12000 Series<br />

Screened. 2kV, 5A<br />

Crydom’s FRS12000 series feature two Crydom <strong>reed</strong> switches connected in<br />

parallel for higher current capability. Available in both open frame and covered<br />

construction (depending upon voltage isolation requirements), the FRS12000<br />

series utilises materials with exceptional RF and temperature performance<br />

characteristics. In addition the coils are partially screened offering extended<br />

RF performance over the HF band.<br />

CONTACT UNITS CONDITIONS FRS12030 FRS12208<br />

Action (form A, B or Latching) A A<br />

Switching Voltage V DC max 20 20<br />

Switching Current A DC max 0.5 0.5<br />

Carry Current A RMS 5 5<br />

Isolation kV DC max 0.5 2<br />

Capacitance pF coil/screen gnd 0.3 0.3<br />

Contact Connections pin position 5 & 8 5 &12<br />

Lifetime operations dry switching 10 9 10 9<br />

Contact Resistance mOhms maximum (typical) 80 (30) 80 (30)<br />

Insulation Resistance Ohms minimum (typical) 10 10 (10 13 ) 10 10 (10 13 )<br />

ESR at 4.5A, 30MHz mOhms typical 90 90<br />

COIL at 20°C<br />

Nominal Working Voltage VDC 24 24<br />

Must Operate VDC max 15 15<br />

Must Release VDC min 4 4<br />

Nominal Resistance ohms +/10% 1150 1000<br />

RF Screening Part Part<br />

RF Screening Connection pin position 17 15<br />

Coil Connections pin position 3 & 11 4 & 13<br />

CONTACT US NOW<br />

UNITED KINGDOM<br />

CRYDOM<br />

T +44 (0)1202 897969<br />

F +44 (0)1202 891918<br />

E magnetics@crydom.com<br />

W www.crydom.co.uk<br />

USA<br />

CRYDOM<br />

T +1 858 715 7200<br />

F +1 858 715 7280<br />

E sales@crydom.com<br />

W www.crydom.com<br />

RELAY<br />

Construction Open Frame Covered<br />

Operate time (incl. bounce) mS 2 2<br />

Release time (incl. bounce) mS 1 1<br />

Contact to all<br />

other terminals kV DC max 0.5 2<br />

Coil to screen kV DC max 0.5 0.5<br />

Capacitance contact to<br />

all other terminals pF contacts open 2.5 3.0<br />

ENVIRONMENTAL<br />

Storage temperature range °C -55 to +125<br />

Operating temperature range °C Limited current* -40 to +85<br />

Shock g 11ms 1/2 sine pk 100<br />

*see graphical data


Many other variants in the FRS12000 family are available with different<br />

coil and contact configurations, as well as a number of pin footprints for<br />

drop-in replacements.<br />

15<br />

MECHANICAL<br />

<strong>radio</strong> <strong>frequency</strong><br />

<strong>reed</strong> <strong>relays</strong>


FRS12000 Series<br />

Miniature Single RF Reed Relay<br />

Offering outstanding RF performance for their size, the FRS12000 series can withstand RF voltages up to<br />

3kV and carry RF currents of 6A at 30MHz. Utilising plastic and encapsulant materials with exceptional<br />

RF and temperature characteristics, the FRS12000 Series RF Reed Relays feature in house manufactured<br />

<strong>reed</strong>switches, with copper plating and high vacuum much revered in the industry for their high power<br />

performance and reliability.<br />

Designed on a standard 0. 1" pin pitch (some variants available on 0.15"), the FRS12000 series can be<br />

fully customised to your requirements, with options for open frame or encapsulated, magnetic screening,<br />

coil voltages, and contact configuration. Crydom have also recently developed a 5kV version with contact<br />

pins exiting the cover for flying lead connection. Contact Crydom for details.<br />

Typical applications for the FRS12000 Series include antenna tuning units, as well as harmonic and co-site<br />

filtering over the HF band.<br />

CONTACT<br />

COIL at 20°C<br />

RELAY<br />

ENVIRONMENTAL<br />

UNITS CONDITIONS FRS12517 FRS12518<br />

Action (form A, B or Latching) A A<br />

Switching Voltage V DC max 20 20<br />

Switching Current A DC max 0.5 0.5<br />

Carry Current A RMS at 30MHz max 3 3<br />

Isolation kV DC max 0.3 3<br />

Capacitance pF coil/screen gnd 0.2 0.2<br />

Contact Connections pin position 5 & 8 5 & 8<br />

Nom. Working Voltage VDC 24 12<br />

Working Voltage Range VDC 18-32 8-16.5<br />

Must Operate VDC max 16 7<br />

Must Release VDC min 2 1<br />

Nominal Resistance ohms +/10% 1500 700<br />

RF Screening Inner/Outer/Full I I & 0<br />

RF Screening Connection pin position 11 11<br />

Coil Connections pin position 3 &10 3 &10<br />

Construction Single Single<br />

Open Frame<br />

With Cover<br />

Operate time (incl. bounce) mS 0.6 1<br />

Release time (incl. bounce) mS 0.4 0.5<br />

Contact to all<br />

other terminals kV DC max 0.1 1.5<br />

Coil to screen kV DC max 0.1 0.5<br />

Capacitance contact to<br />

all other terms pF contacts open 1.5 2.0<br />

Storage temperature range °C -55°C to +125°C<br />

Operating temperature rang °C -40°C to +85°C<br />

Lifetime ops dry switching 10 9<br />

ops Rated load Consult factory<br />

Shock g 11ms 1/2 sine pk 100<br />

Bump g 6ms 1/2 sine pk 40<br />

Vibration g 60-500Hz 20<br />

FRS12000S-2000UK<br />

Control over power<br />

• Up to 3KV Isolation<br />

• 6A Carry Current (up<br />

to 30MHz)<br />

• Excellent RF<br />

Characteristics<br />

• Designed for HF<br />

Applications<br />

• Compact Package on<br />

0.1 " Pin Pitch<br />

• Full Customising<br />

Facility<br />

Crydom Magnetics Ltd<br />

7 Cobham Road<br />

Ferndown Industrial Estate<br />

Wimborne<br />

Dorset BH21 7PE<br />

Tel: +44 (0) 1202 897969<br />

Fax: +44 (0) 1202 891918<br />

magnetics@crydom.com<br />

www.crydom.co.uk


FRS12000 Series<br />

Miniature RF Reed Relay<br />

MECHANICAL<br />

Control over power<br />

28.65 Max<br />

(1.13“)<br />

9.80 Max<br />

(0.38“)<br />

11.50<br />

(0.45“)<br />

SINGLE WITH COVER<br />

SINGLE<br />

WITH COVER<br />

SINGLE<br />

OPEN FRAME<br />

10.00<br />

(0.39“)<br />

11.50<br />

(0.15“)<br />

SINGLE<br />

OPEN FRAME<br />

8.00 Max<br />

(0.31“)<br />

25.40<br />

(1.00“)<br />

20.32<br />

(0.80“)<br />

1 2 3 4<br />

5 6<br />

7 8<br />

9<br />

10 11 12<br />

5.08<br />

(0.20“)<br />

2.54<br />

(0.10“)<br />

PIN SIZE (SINGLE)<br />

PINS 3, 10 & 11 0.63 SQUARE (0.025“)<br />

PINS 5 & 8<br />

0.7 (0.027“) dia.<br />

2.54<br />

(0.10“)<br />

17<br />

5<br />

9<br />

1 2 3 4<br />

13 14<br />

6 7 8<br />

10 11 12<br />

30.60<br />

(1.20“)<br />

15 16<br />

PIN SIZE (DOUBLE-EXTENDED FOOT)<br />

PINS 3, 11 & 17 0.63 SQUARE (0.025“)<br />

PINS 5 & 8<br />

0.7 (0.027“) dia.<br />

R<br />

E<br />

G<br />

IS<br />

D<br />

E<br />

R<br />

T E<br />

FM02050<br />

UKAS<br />

QUALITY<br />

MANAGEMENT<br />

003<br />

Crydom Magnetics Ltd<br />

7 Cobham Road<br />

Ferndown Industrial Estate<br />

Wimborne<br />

Dorset BH21 7PE<br />

Tel: +44 (0) 1202 897969<br />

Fax: +44 (0) 1202 891918<br />

magnetics@crydom.com<br />

www.crydom.co.uk


10<br />

● New Fully<br />

Screened Coil<br />

for Low RF Loss<br />

● Up to 9kVDC<br />

and 6A at<br />

30MHz<br />

● Drop-in<br />

replacement for<br />

FRD12000<br />

Series<br />

● Ideal for<br />

Antenna Tuning<br />

Units<br />

● Customising<br />

Facility<br />

FRD13000 Series<br />

Fully Screened. 9kV, 6A<br />

A development of the FRD12000 series, this design has a complete RF screen<br />

around the coil assembly, offering a very low loss transmission path. This results<br />

in better carry current performance at elevated temperatures. This device also<br />

features an anti-corona sleeve shrouding the <strong>reed</strong> switch contact for improved<br />

peak RF voltage isolation.<br />

CONTACT UNITS CONDITIONS FRD13503 FRD13504<br />

Action (form A, B or Latching) A B<br />

Switching Voltage V DC max 20 20<br />

Switching Current A DC max 1 1<br />

Carry Current A RMS max 6 6<br />

Isolation kV DC max 9 9<br />

Isolation kV RF peak (f=2MHz) 8 8<br />

Capacitance pF coil/screen gnd 0.5 0.5<br />

Lifetime operations dry switching 10 9 10 9<br />

Contact Resistance mOhms maximum (typical) 50 (15) 50 (15)<br />

Insulation Resistance Ohms minimum (typical) 10 10 (10 13 ) 10 10 (10 13 )<br />

ESR at 4.5A, 30MHz mOhms typical 30 30<br />

COIL at 20°C<br />

Nominal Working Voltage VDC 24 24<br />

Must Operate VDC max 15 16<br />

Must Release VDC min 3 3<br />

Nominal Resistance Ohms +/10% 900 900<br />

RF Screening Full Full<br />

RF Screening Connection pin position 1 & 8 1 & 8<br />

Coil Connections pin position 4 & 5 4 & 5(+)<br />

RELAY<br />

Operate time (incl. bounce) mS 2 1<br />

Release time mS 1 2<br />

Isolation contact to all other terminals kV DC max 9 9<br />

Isolation coil to screen kV DC max 0.5 0.5<br />

Capacitance contact to all other terminals pF contacts open 1.5 1.5<br />

CONTACT US NOW<br />

UNITED KINGDOM<br />

CRYDOM<br />

T +44 (0)1202 897969<br />

F +44 (0)1202 891918<br />

E magnetics@crydom.com<br />

W www.crydom.co.uk<br />

USA<br />

CRYDOM<br />

T +1 858 715 7200<br />

F +1 858 715 7280<br />

E sales@crydom.com<br />

W www.crydom.com<br />

ENVIRONMENTAL<br />

Storage temperature range °C -55 to +125<br />

Operating temperature range °C Limited current* -40 to +85<br />

Shock g 11ms 1/2 sine pk 100<br />

Bump g 6ms 1/2 sine pk 40<br />

Vibration g 10- 500Hz 10<br />

*see graphical data


11<br />

MECHANICAL<br />

<strong>radio</strong> <strong>frequency</strong><br />

<strong>reed</strong> <strong>relays</strong>


16<br />

● Bistable<br />

Latching Relay<br />

● 0.5 ms Coil<br />

Pulse length<br />

● 3.5kV DC<br />

Isolation<br />

● 1.5A Carry<br />

Current<br />

● RF & Magnetic<br />

Screening<br />

● Approved to MIL<br />

standards for<br />

Bump, Shock<br />

and Vibration<br />

FRS22012<br />

Fast Latching, Screened. 3.5kV, 1.5A<br />

The FRS22012 latching RF <strong>reed</strong> relay designed for manpack portable<br />

HF <strong>radio</strong> systems where power resources are limited. The relay is capable of<br />

withstanding 3.5kV between contacts and carrying 1.5A current at 30MHz.<br />

The device features RF and magnetic screening, allowing close mounting, and<br />

a unique coil design enabling switching with coil pulse lengths down to 0.5ms,<br />

further reducing power supply demands. The FRS22012 is an ideal choice for<br />

applications where board space is at a premium but where RF performance<br />

is demanded.<br />

CONTACT UNITS CONDITIONS FRS22012<br />

Action (form A, B or Latching)<br />

Latching<br />

Switching Voltage V DC max 20<br />

Switching Current A DC max 0.5<br />

Carry Current A RMS at 30MHz 1.5<br />

Isolation kV DC max 3.5<br />

Capacitance pF coil/screen gnd 0.2<br />

Contact Connections pin number 3 & 4<br />

Lifetime operations dry switching 10 9<br />

Contact Resistance mOhms maximum (typical) 80 (30)<br />

Insulation Resistance Ohms minimum (typical) 10 10 (10 13 )<br />

ESR at 1.5A, 30MHz mOhms typical 400<br />

COIL at 20°C<br />

Nom. Working Voltage VDC 12<br />

Min. pulse length ms Minimum 0.5<br />

Operate time ms diode fitted 0.5<br />

Release time ms diode fitted 0.5<br />

Nominal Resistance ohms +/10% 500<br />

RF Screening<br />

Part<br />

RF Screening Connection pin number 7<br />

Coil Connections Set pin number 1 & 2(+)<br />

Reset 5 & 6(+)<br />

CONTACT US NOW<br />

UNITED KINGDOM<br />

CRYDOM<br />

T +44 (0)1202 897969<br />

F +44 (0)1202 891918<br />

E magnetics@crydom.com<br />

W www.crydom.co.uk<br />

RELAY<br />

Isolation contact to coil/screen kV DC max 4<br />

Capacitance contact to all other terminals pF contacts open 2.5<br />

Capacitance contact to all other terminals pF contacts closed 4.0<br />

ENVIRONMENTAL<br />

Operating temperature range °C -40 to +85<br />

Storage temperature range °C -40 to +125<br />

USA<br />

CRYDOM<br />

T +1 858 715 7200<br />

F +1 858 715 7280<br />

E sales@crydom.com<br />

W www.crydom.com


17<br />

MECHANICAL<br />

1<br />

7<br />

<strong>radio</strong> <strong>frequency</strong><br />

<strong>reed</strong> <strong>relays</strong>


12<br />

● Up to 20A<br />

Carry Current<br />

at 30MHz<br />

● 6.5kV DC<br />

Isolation<br />

● Fully Screened<br />

Coil for Low RF<br />

Loss<br />

● Cost Effective<br />

alternative<br />

to Vacuum<br />

Ceramic<br />

Devices<br />

● Suitable for<br />

1 kW HF<br />

Transmitters<br />

FRD30000 Series<br />

Fully Screened. 6.5kV, 20A<br />

This flagship relay series offered by Crydom employs multiple high vacuum <strong>reed</strong><br />

switch contacts ensuring excellent performance and reliability for high voltage<br />

and heavy carry current applications. The two basic models, FRD32061 and<br />

FRD32062 will carry currents of 12 and 20A respectively at 30MHz and feature<br />

silver plated, fully screened coil assemblies for ultra-low RF losses. Typical<br />

applications include over the horizon (OTH) HF radar systems and 1kW base<br />

station transmitters.<br />

CONTACT UNITS CONDITIONS FRD32061 FRD32062<br />

Action (form A, B or Latching) A A<br />

Switching Voltage V DC max 20 20<br />

Switching Current A DC max 1 1<br />

Carry Current A RMS at 30MHz max 12 20<br />

Isolation kV DC max 6 6.5<br />

Capacitance (max.) pF coil/screen gnd 2 2<br />

Lifetime operations dry switching 10 9 10 9<br />

24V, 1A 10 7 -10 8 10 7 -10 8<br />

Contact Resistance mOhms maximum (typical) 50 (10) 50 (10)<br />

Insulation Resistance Ohms minimum (typical) 10 10 (10 13 ) 10 10 (10 13 )<br />

COIL at 20’C<br />

Nominal Working Voltage VDC 24 24<br />

Must Operate VDC max 16 16<br />

Must Release VDC min 4 4<br />

Nominal Resistance Ohms +/10% 430 270<br />

RF Screening Full Full<br />

RF Screening Connection pin number Via Mounting Screws Via Mounting Screws<br />

CONTACT US NOW<br />

UNITED KINGDOM<br />

CRYDOM<br />

T +44 (0)1202 897969<br />

F +44 (0)1202 891918<br />

E magnetics@crydom.com<br />

W www.crydom.co.uk<br />

RELAY<br />

Operate time (incl. bounce) mS 5 5<br />

Release time mS 3 3<br />

Isolation contact to all<br />

other terminals kV DC max 10 10<br />

Isolation coil to screen kV DC max 0.5 0.5<br />

Capacitance contact to<br />

all other terminals pF contacts open 6.0 6.0<br />

ENVIRONMENTAL<br />

Storage temperature range °C -55 to +125<br />

Operating temperature range °C -40 to +85<br />

USA<br />

CRYDOM<br />

T +1 858 715 7200<br />

F +1 858 715 7280<br />

E sales@crydom.com<br />

W www.crydom.com


13<br />

MECHANICAL<br />

( . "<br />

<strong>radio</strong> <strong>frequency</strong><br />

<strong>reed</strong> <strong>relays</strong>


24<br />

● Compact<br />

Footprint<br />

● Designed<br />

Specifically for<br />

High Voltage<br />

● Rhodium<br />

Contacts for<br />

Low Resistance<br />

● 3 or 5kV<br />

Isolation<br />

between<br />

Contacts<br />

● Excellent<br />

Lifetime<br />

Characteristics<br />

S Series<br />

5kV, 10W<br />

Developed for the high voltage ATE market, where PCB space is at a premium,<br />

the S Series High Voltage Reed Relay offers a 3 or 5kV isolation performance<br />

in a 30mm size package. With low contact resistance, the S Series High<br />

Voltage Reed Relay will satisfy the many high voltage applications at DC and<br />

low <strong>frequency</strong>, where performance and reliability are paramount.<br />

CONTACT UNITS CONDITIONS 3KV FORM A 5KV FORM A<br />

Contact material Rhodium Rhodium<br />

Isolation across contacts kV DC or AC peak 3 5<br />

Max. carry current A DC or AC rms (60Hz) 2 2<br />

Max. switching power W 10 10<br />

Max. switching voltage V DC or AC peak 20 20<br />

Max. switching current A DC or AC peak 0.5 0.5<br />

Capacitance across contacts pF coil/screen grounded


25<br />

MECHANICAL<br />