Case #2: Post-Placement Utilization of the<br />

Inclusive Tooth Replacement Solution<br />

A 41-year-old male presented with a chief complaint of:<br />

“I had my molar taken out over 10 years ago, and I would<br />

like an implant to replace it.” Following appropriate workup,<br />

a 5.2 mm x 8 mm Inclusive Tapered Implant was placed<br />

without complication in the edentulous area #19. The<br />

5.2 mm diameter implant features a platform-switching<br />

design that utilizes 4.5 mm diameter prosthetic components.<br />

A flaring Inclusive ® Healing Abutment 4.5 mm x 5.7 mm x<br />

3 mm was tightened to 15 Ncm into the implant in a singlestage<br />

procedure.<br />

To ensure proper tissue management specific to his anatomy,<br />

in the interest of gingival health and natural esthetics, the<br />

patient elected to take advantage of the custom healing<br />

features of the post-placement Tooth Replacement Solution.<br />

An advantage of the post-placement solution is that the<br />

custom temporary components are designed and milled<br />

based on an implant-level impression, mitigating or even<br />

eliminating any need for chairside adjustment of the custom<br />

components upon delivery. Continued on page 62<br />

Upon return to the office post-implant placement,<br />

the patient exhibited excellent soft tissue healing<br />

around the standard titanium healing abutment.<br />

The resulting tissue formation, however, is of a<br />

generic, round geometry commonly encountered<br />

with stock components, rather than being optimized<br />

for the anatomy of the edentulous space.<br />

1<br />

The stock healing abutment was removed so that<br />

a closed-tray impression coping could be seated<br />

on the implant and the closed-tray screw handtightened.<br />

2<br />