12a<br />
As sufficient initial implant stability was achieved in this case (35–40 Ncm), the decision was made to immediately<br />
temporize the implant with the custom temporary abutment and BioTemps crown.<br />
12b<br />
13<br />
Both the custom abutment and BioTemps crown<br />
exhibited excellent fit and orientation in all dimensions.<br />
It was further confirmed that the BioTemps<br />
crown was out of occlusion by 1.5 mm, which is<br />
desirable for immediate temporization so as to<br />
avoid any lateral micromotion on the neophyte<br />
implant that might compromise its osseointegration.<br />
The patient tolerated the procedure<br />
very well, and there were no operative complications.<br />
Postoperative home care instructions were<br />
reviewed thoroughly with her, and she was<br />
appointed in one month for follow-up.<br />
14<br />
A three-month postoperative checkup revealed<br />
excellent healing of the soft tissues. Final<br />
impressions were scheduled to follow one<br />
month later.<br />