11.09.2014 Views

PDF Download - Glidewell Dental Labs

PDF Download - Glidewell Dental Labs

PDF Download - Glidewell Dental Labs

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Case #1: Implant Placement and Immediate Non-Functional Temporization<br />

The patient is a 46-year-old female who initially presented<br />

to our office with a chief complaint of: “I have a brokendown<br />

tooth that I would like to have extracted and replaced<br />

with an implant.” After evaluation of the patient, the crown<br />

of tooth #4 was found to be fractured, and decay was noted<br />

subgingivally. The tooth was determined to be nonrestorable,<br />

and was atraumatically extracted under local anesthesia,<br />

with care taken to preserve the buccal plate. The socket<br />

was gently currettaged and Puros ® Cortico-Cancellous Particulate<br />

Allograft material (Zimmer <strong>Dental</strong>; Carlsbad, Calif.)<br />

was placed in the extraction site for socket preservation and<br />

covered with a BioMend ® Absorbable Collagen Membrane<br />

(Zimmer <strong>Dental</strong>). The membrane was then secured using<br />

4-0 Vicryl ® suture (Ethicon Inc; Somerville, N.J.).<br />

After four months, the patient returned to our office for<br />

evaluation, during which the extraction site and graft were<br />

determined to have adequately matured to proceed with<br />

implant placement. After reviewing the CBCT scan in the<br />

In2Guide implant planning software (Cybermed Inc.;<br />

Irvine, Calif.), the decision was made to place a 3.7 mm x<br />

10 mm Inclusive ® Tapered Implant.<br />

1a<br />

The requisite polyvinyl siloxane impressions were taken, as well as an accurate bite registration and preoperative intraoral<br />

photographs, including selection of the shade for the BioTemps ® provisional crown.<br />

1b<br />

2<br />

The diagnostic records were submitted,<br />

along with a completed Inclusive Tooth<br />

Replacement Solution digital Rx, to<br />

<strong>Glidewell</strong> Laboratories for fabrication<br />

of the Inclusive Tooth Replacement<br />

Solution components. Upon receipt of the<br />

patient’s diagnostic records and digital<br />

Rx, the Inclusive Tooth Replacement<br />

Solution components were fabricated<br />

and forwarded to our office for implant<br />

placement and temporization.<br />

✔<br />

James Smith<br />

10-5217558<br />

drjsmith6585@yahoo.com<br />

123 Main Street Suite #1 Anywhere, USA<br />

Jane<br />

Doe<br />

✔<br />

4 A3<br />

Please fabricate components for replacement of #4.<br />

J Smith<br />

555-555-5555<br />

✔<br />

✔<br />

✔<br />

✔<br />

1265287<br />

✔<br />

✔ Shade photos<br />

54<br />

– www.inclusivemagazine.com –

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!