EEG and Brain Connectivity: A Tutorial - Bio-Medical Instruments, Inc.
EEG and Brain Connectivity: A Tutorial - Bio-Medical Instruments, Inc.
EEG and Brain Connectivity: A Tutorial - Bio-Medical Instruments, Inc.
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Fig. 33 – Example of phase differences of the time series of instantaneous<br />
phase re-set for all 171 combinations of 19 electrodes. Analyses were<br />
produced using the NeuroGuide Lexicor demo from the download at<br />
www.appliedneuroscience.com<br />
40 – Bi-Spectral Cross-Frequency Power Correlations<br />
A common method of evaluating bi-spectral relations is to compute<br />
the cross-frequency power correlation (Linas et al, 2005). The method<br />
involves computing the covariance of power at each frequency bin with<br />
respect to all other frequency bins. An example is shown for the crossfrequency<br />
power correlations from 1 to 50 Hz in wakefulness, drowsiness<br />
<strong>and</strong> sleep in the same subject as shown in<br />
Fig. 34 – Example of bi-spectrum of cross-frequency power correlations<br />
from 1 to 50 Hz from Cz in the same subject but at different brain states, i.e.,<br />
wakefulness, drowsy <strong>and</strong> sleep.<br />
41- Cross-Frequency Phase Synchrony or m:n Phase Synchronization