(3) PI to P mode switch over by <strong>com</strong>paring Acceleration <strong>com</strong>mand.<br />

When the Acceleration <strong>com</strong>mand is less than Cn018 PI control is selected.<br />

When the Acceleration <strong>com</strong>mand is greater than Cn018 P control is selected.<br />

As shown in diagram below:<br />

Speed<br />

Cn018<br />

PI/P-Mode Switching Condition<br />

(Acceleration)<br />

Acceleration Command<br />

(4) PI to P mode switch over by <strong>com</strong>paring Position Error value.<br />

When the Position Error value is less than Cn019 PI control is selected.<br />

When the Position Error value is greater than Cn019 P control is selected.<br />

As shown in diagram below:<br />

(5) PI to P mode switch over by PCNT input contact.<br />

When the PCNT input contact is open PI control is selected.<br />

When the PCNT input contact is closed P control is selected.<br />

Note: Input contacts status “1” (ON) and “0” (OFF).<br />

Please check 5-6-1 to set the required high /Low signal levels (PNP/NPN) selection.<br />

Switch PI/P<br />

by PCNT input contact<br />

1<br />

0<br />

Status of contact PCNT<br />

Enable<br />

PI control<br />

P control<br />

PI control<br />

5-24