2-1-6 TB Terminal<br />

Name<br />

Control circuit power input<br />

terminal<br />

Main circuit power input<br />

terminal<br />

External regeneration<br />

resistance terminal<br />

Regeneration terminal<br />

<strong>com</strong>mon point<br />

Internal regeneration<br />

resistance terminal<br />

Motor-power output<br />

terminal<br />

Motor-case grounding<br />

terminal<br />

Terminal<br />

Sign<br />

r<br />

s<br />

R<br />

S<br />

T<br />

P<br />

PC<br />

P1<br />

U<br />

V<br />

W<br />

FG<br />

Detail<br />

Connecting to external AC Power.<br />

Single Phase 200~230VAC +10 ~ -15% , 50/60Hz ±5%<br />

Connecting to external AC Power.<br />

Single / 3 Phase 200~230VAC +10 ~ -15% , 50/60Hz ±5%<br />

Please refer to Cn012 to see resistance value, when using external<br />

regeneration resistance. After installing regeneration resistance, set the<br />

resistance power in Cn012.<br />

*If NOT using external regeneration resistance, PC-P1 is a short<br />

circuit, do not connect P terminal.<br />

*When using external regeneration, equip regeneration resistance<br />

between PC-P, do not connect P1 terminal.<br />

Motor terminal wire is red<br />

Motor terminal wire is white<br />

Motor terminal wire is black<br />

Motor terminal wire is green or yellow-green.<br />