Parameter Name & Function Default Unit<br />

★Hn514.0<br />

★Hn514.1<br />

DO-1<br />

Setting<br />

Explanation<br />

Signal<br />

Functions<br />

01 RDY Servo Ready<br />

02 ALM Alarm<br />

03 ZS Zero Speed<br />

04 BI Brake Signal<br />

05 INS In Speed<br />

06 INP In Position<br />

07 HOME HOME<br />

08 INT In Torque<br />

DO-1<br />

★Hn514.2 Setting<br />

Explanation<br />

0 Close, when the output is activated.<br />

1 Open, when the output is activated.<br />

DO-2<br />

★Hn515<br />

Plearse refer to Hn514<br />

★Hn516<br />

★Hn517<br />

DO-3<br />

Plearse refer to Hn514<br />

DO-4<br />

Plearse refer to Hn514<br />

New setting will be<strong>com</strong>e effective after re-cycling the power.<br />

01 X<br />

0 X<br />

002 X<br />

003 X<br />

006 X<br />

Setting<br />

Range<br />

01<br />

│<br />

08<br />

0<br />

│<br />

1<br />

001<br />

│<br />

108<br />

001<br />

│<br />

108<br />

001<br />

│<br />

108<br />

Control<br />

Mode<br />

Chapter<br />

ALL 5-6-1<br />

ALL 5-6-1<br />

ALL 5-6-1<br />

ALL 5-6-1<br />

Warning! If any of programmable Inputs of DI-1 ~ DI-13 are set for the same type of function<br />

then the logic state selection ( NO or NC selection) for these inputs must be the same type.<br />

Otherwise an Alarm will be displayed. AL-07 (Abnormal DI/DO programming).<br />

6-28