Setting for the Power of External Regeneration Resistor<br />

When using external regeneration resistor, the power value (Watts) must be set in parameter Cn012.<br />

Parameter Name Default Unit Setting Range Control Mode<br />

Cn012<br />

Watts setting for<br />

External Regeneration<br />

Resistor<br />

60 ~150 W 0~10000 ALL<br />

Wiring for External Regeneration Resistor<br />

When external Regeneration Resistor is used, must remove the link between PC and P1 on TB1 Terminal.<br />

Then the resistor should be installed between terminals P and PC.<br />

For safety, use of resistors with thermal protection is re<strong>com</strong>mended.<br />

The thermal switch contact can then be interlocked to disable drive or remove power if necessary.<br />

Refer to connection diagram below:<br />

When installing Regeneration Resistors care must be taken as the resistor absorbs the regeneration power,<br />

and it is possible to generate the high temperatures above 100°C.<br />

Provide the necessary cooling and use appropriate high temperature wires and ensure there has enough<br />

space between regeneration resistor and other materials.<br />