4.Parameter Setting for Electronic Gear Ratio<br />
Setting gear ratio Numerator and denominator parameters:<br />
Numerator and denominator values of the calculated electronic gear ratio must be entered in the required<br />
parameters.<br />
These two values have to be integer and with a value within the specified range in the table below.<br />
Parameter<br />
Setting Control<br />
Name Default Unit<br />
Signal<br />
Range Mode<br />
Pn302 Numerator of Electronic Gear Ratio 1 1 X 1~50000 Pi/Pe<br />
Pn303 Numerator of Electronic Gear Ratio 2 1 X 1~50000 Pi/Pe<br />
Pn304 Numerator of Electronic Gear Ratio 3 1 X 1~50000 Pi/Pe<br />
Pn305 Numerator of Electronic Gear Ratio 4 1 X 1~50000 Pi/Pe<br />
★Pn306 Denominator of Electronic Gear Ratio 1 X 1~50000 Pi/Pe<br />
New setting will be<strong>com</strong>e effective after re-cycling the power.<br />
This device provides 4 selections of Numerator for Electronic Gear Ratio.<br />
Input contacts GN1 and GN2 can be used to select the required Numerator for the Electronic Gear Ratio<br />
According to the table below.<br />
Input<br />
Contact GN2<br />
Input Contact<br />
GN1<br />
Numerator of Electronic Gear Ratio<br />
Control<br />
Mode<br />
0 0<br />
0 1<br />
1 0<br />
1 1<br />
Numerator of Electronic Gear Ratio 1<br />
Pn302<br />
Numerator of Electronic Gear Ratio 2<br />
Pn303<br />
Numerator of Electronic Gear Ratio 3<br />
Pn304<br />
Numerator of Electronic Gear Ratio 4<br />
Pn305<br />
Pi/Pe<br />
Note: Input contacts status “1” (ON) and “0” (OFF)<br />
Please check 5-6-1 to set the required high /Low signal levels (PNP/NPN) selection.<br />