5-4-1 External Pulse Command<br />

Four types of external position pulse <strong>com</strong>mand signals can be interfaced,<br />

These can be selected from the list below.<br />

Position pulse signal logic can be selected Positive or negative as required.<br />

Parameter<br />

Signal<br />

Name Setting Description<br />

0 (Pulse)+(Sign)<br />

Control<br />

Mode<br />

★Pn301.0<br />

Position pulse<br />

<strong>com</strong>mand selection<br />

1 (CCW)and (CW) pulse<br />

2 AB-Phase Pulsex2<br />

Pe<br />

3 AB-Phase Pulsex4<br />

★Pn301.1<br />

Position pulse 0 Positive Logic<br />

<strong>com</strong>mand logic<br />

selection 1 Negative Logic<br />

Pe<br />

New setting will be<strong>com</strong>e effective after re-cycling the power.<br />

Position pulse<br />

<strong>com</strong>mand types<br />

Positive Logic<br />

Negative Logic<br />

CCW Command CW Command CCW Command CW Command<br />

(Pulse)+<br />

(Sign)<br />

(CCW)/<br />

(CW) Pulse<br />

AB-Phase Pulse<br />

5-32