06.09.2014 Views

Hose and Flexible Tubing (MS-01-180;rev_6;en-US) - Swagelok

Hose and Flexible Tubing (MS-01-180;rev_6;en-US) - Swagelok

Hose and Flexible Tubing (MS-01-180;rev_6;en-US) - Swagelok

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

NG Series Nylon <strong>Hose</strong><br />

Features<br />

■ Electrically conductive nylon hose for CNG.<br />

■ Static dissipative, smooth-bore nylon core ().<br />

■ Size range of 1/4 <strong>and</strong> 3/8 in. <strong>and</strong> working pressures up to<br />

5000 psig (344 bar).<br />

■ Internal fiber reinforcem<strong>en</strong>t <strong>en</strong>hances hose pressure rating.<br />

■ Cover includes a blue stripe which provides an easily<br />

visible indicator of the static dissipative core.<br />

■ Perforated polyurethane cover resists abrasion.<br />

■ Designed for use with natural gas where static dissipation<br />

is required.<br />

Single hose<br />

Twin hose (high-pressure v<strong>en</strong>t)<br />

V<strong>en</strong>t hose (low-pressure v<strong>en</strong>t)<br />

<strong>Hose</strong> <strong>and</strong> <strong>Flexible</strong> <strong>Tubing</strong> 67<br />

■ Single, twin bonded, <strong>and</strong> v<strong>en</strong>t bonded hoses are available in<br />

custom assemblies.<br />

302 SS spring guard Fiber reinforcem<strong>en</strong>t<br />

316 SS <strong>en</strong>d<br />

connections<br />

Perforated polyurethane cover<br />

Static dissipative core<br />

Technical Data<br />

<strong>Hose</strong><br />

Style<br />

(Series)<br />

Single<br />

(NGS)<br />

Twin<br />

(NGT)<br />

V<strong>en</strong>t➀<br />

(NGV)<br />

Nominal<br />

<strong>Hose</strong> Size<br />

in. (mm)<br />

Inside<br />

Diameter<br />

in. (mm)<br />

Outside<br />

Diameter<br />

in. (mm)<br />

➀ Low-pressure v<strong>en</strong>t line does not have static dissipative core.<br />

Minimum<br />

Inside<br />

B<strong>en</strong>d<br />

Radius<br />

in. (cm)<br />

Temperature<br />

Range<br />

°F (°C)<br />

Working<br />

Pressure<br />

at 70°F (20°C)<br />

psig (bar)<br />

Burst<br />

Pressure<br />

at 70°F (20°C)<br />

psig (bar)<br />

Bulk<br />

<strong>Hose</strong><br />

Weight<br />

lb/ft (kg/m)<br />

0.12 (0.17)<br />

1/4 (6.4) 0.26 (6.6) 0.63 (16.0) 2.00 (5.08)<br />

5000 (344) 20 000 (1378)<br />

3/8 (9.6) 0.38 (9.6) 0.77 (19.6) 4.00 (10.2) 0.15 (0.22)<br />

1/4 (6.4) 0.26 (6.6) 0.63 (16.0) 2.00 (5.08) Fill <strong>and</strong> v<strong>en</strong>t Fill <strong>and</strong> v<strong>en</strong>t 0.25 (0.37)<br />

3/8 (9.6) 0.38 (9.6) 0.77 (19.6) 4.00 (10.2) –40 to 150 5000 (344) 20 000 (1378) 0.30 (0.44)<br />

(–40 to 65)<br />

Fill 0.26 (6.6) Fill 0.63 (16.0)<br />

1/4 (6.4)<br />

2.00 (5.08)<br />

0.15 (0.22)<br />

V<strong>en</strong>t 0.26 (6.6) V<strong>en</strong>t 0.63 (16.0)<br />

Fill 5000 (344) Fill 20 000 (1378)<br />

Fill 0.38 (9.6) Fill 0.38 (9.6)<br />

V<strong>en</strong>t 1500 (103) V<strong>en</strong>t 6 000 (413)<br />

3/8 (9.6)<br />

4.00 (10.2) 0.25 (0.37)<br />

V<strong>en</strong>t 0.26 (6.6) V<strong>en</strong>t 0.63 (16.0)<br />

NYLON<br />

Testing<br />

Every <strong>Swagelok</strong> NG series hose assembly is factory tested<br />

for electrical conductivity.<br />

Cleaning <strong>and</strong> Packaging<br />

<strong>Swagelok</strong> conductive core hose compon<strong>en</strong>ts are cleaned in<br />

accordance with <strong>Swagelok</strong> St<strong>and</strong>ard Cleaning <strong>and</strong> Packaging<br />

(SC-10), <strong>MS</strong>-06-62. Each hose is bagged individually <strong>and</strong><br />

boxed; longer hoses are coiled, bagged, <strong>and</strong> boxed.<br />

Warning:<br />

All equipm<strong>en</strong>t must be properly grounded to allow<br />

static dissipation <strong>and</strong> help to p<strong>rev</strong><strong>en</strong>t static sparking.<br />

Periodic inspection of hose assembly is<br />

recomm<strong>en</strong>ded. End-to-<strong>en</strong>d electrical resistance of<br />

the hose assembly must not exceed 5 M.<br />

See next page for ordering information.