According to assumptions <strong>and</strong> calculations the activated sludge system will give the best treatment<br />

efficiency in terms of BOD, nitrogen <strong>and</strong> phosphorous removal. An activated sludge system will achieve<br />

st<strong>and</strong>ard A requirements according to Malaysian recommendations <strong>and</strong> according to Malaysian st<strong>and</strong>ard<br />

the activated-sludge system will have an footprint area of around 1 ha if the system receives water from<br />

more than 10 000 people. The current pond received waste water from around 10 500 people at the time<br />

this report was written.<br />

The treatment technology will however be comparatively expensive to build <strong>and</strong> run. An activated sludge<br />

system is also less effective, compared to the other suggested alternatives, in removing pathogens <strong>and</strong><br />

there may be a need for some pathogen removal device after activated-sludge treatment.<br />

The second suggestion to upgrade the current treatment pond does not achieve the same treatment<br />

efficiency as the activated sludge system. On the other h<strong>and</strong> it is less expensive to run <strong>and</strong> easier to<br />

maintain. It will also reduce pathogens more effectively than an activated sludge system. According to<br />

assumptions <strong>and</strong> calculations it will be wise to install oxygen generators as the upgraded treatment pond<br />

system is overloaded <strong>and</strong> the oxygen the algae produce is not sufficient for organic breakdown. If<br />

conservative assumptions <strong>and</strong> calculations are made the treated water will barely fulfill the requirements<br />

for Malaysian st<strong>and</strong>ard A, but at a low price. If optimistic assumptions are made, the treatment result will<br />

reach down just below st<strong>and</strong>ard A.<br />

Our recommendations are for financing reasons <strong>and</strong> for simplicity to keep the old treatment plant,<br />

improve it by installing screening, installing aeration <strong>and</strong> baffles <strong>and</strong> redirecting the flow from parallel<br />

flow to serial flow through all four treatment ponds.<br />