Total Suspended Solids<br />
TSS analyses were made by filtering 100 ml of sampling through a microfilter (Whatman, GF/C<br />
glasfaser microfilter). In order to force the sampling water through the filter, an air compressor<br />
was used to create low pressure in the bottle receiving the filtered water (see Figure 7.2). The<br />
filters were measured before <strong>and</strong> after filtering. To eliminate the weight contribution of water, the<br />
filters were dried in an oven at around 110°C for one hour after filtering, but before final<br />
measuring.<br />
Figure 7.2: Sample water was filled in the upper glass container. The air compressor (right in the<br />
picture) created a low pressure in the receiving container (containing filtered water in the picture)<br />
(Sxabo & <strong>Engle</strong>, 2010).<br />