5. Vertical / Horizontal Adjustment<br />
- Receive the Retma signal (for PAL system)<br />
- Set all condition to the Normal I. (Push the NORMAL key of the service remocon.)<br />
5-1. V-CENTER<br />
- Push the V.C(P/N) key of the service remocon, then it is displayed like ‘Fig 2’<br />
- Adjust to use DATA UP/DOWN key so that the center of Retma Pattern may be located in the Vertical center of the CRT<br />
<br />
8<br />
13<br />
0<br />
0<br />
71<br />
71<br />
2<br />
H.P(P)<br />
H.P(N)<br />
V.C(P)<br />
V.C(N)<br />
V.H(P)<br />
V.H(N)<br />
V.L<br />
<br />
5-2. V-HEIGHT<br />
- Push the V.H(P/N) key of the service remocon, and the cursor indicate V.H(P) (Fig 2).<br />
- Adjust to use DATA UP/DOWN key so that the Height number “9” may be seen at the edge<br />
above or below from the end of the CRT.<br />