Chapter 3 Configuring and Setting a PLC System<br />

extension rack pasted follow the input/output device addresses<br />

assigned to the modules on the extension rack copied.<br />

• Comments about the modules: The comments about the modules on the extension rack copied<br />

are copied into the modules on the extension rack pasted.<br />

• Parameters in the modules: The parameters in the modules on the extension rack cut are<br />

copied into the modules on the extension rack pasted.<br />

• Data registers: The data register addresses assigned to the modules on the extension rack<br />

pasted follows the data registers addresses assigned to the modules on the<br />

extension rack copied.<br />

• Parameters in the intelligent modules: The setting of the parameters in the intelligent modules<br />

is not copied, and is restored to the default values.<br />

*. Some intelligent modules can be set by means of exclusive configuration tools. Please refer to section 3.4.4 for<br />

more information.<br />

3.2.2.14 Dragging an Extension Rack<br />

Drag an extension rack to another extension rack when the left mouse button is held. The two<br />

extension racks will be interchanged. When the extension rack is dragged, the input/output devices<br />

assigned to the modules on the extension rack, the comments about the modules on the extension<br />

rack, the parameters in the modules on the extension rack, the data registers assigned to the<br />

modules on the extension rack, and the parameters in the intelligent modules are also dragged.<br />

However, the main rack is always at the top of the system configuration area.<br />

3.2.2.15 Rearranging the Input/Output Devices<br />

During a module configuration, modules may be dragged or copied/cut/pasted several times. The<br />

input/output devices may be automatically assigned to the modules by the system, and may not be<br />

arranged in order. After users click Input/Output Device Rearrange on the File menu, the<br />

input/output devices assigned to all modules will be rearranged according to the slot numbers and<br />

the rack numbers.<br />

The rearrangement of the input/output devices does not change the data registers assigned to the<br />

modules. During the rearrangement, if the input/output devices assigned to the modules conflicts<br />

with the data registers assigned to the modules, the system will skip the data registers assigned to<br />

the module, and provide the devices which can be used.<br />