ISPSoft User Manual
ISPSoft User Manual ISPSoft User Manual
Chapter 17 Data Backup and Data Restoration which exists in the computer, the file will be overwritten after the data restoration is peformed. (4) After the users make sure that the summary in the CARD Utility window is consistent with the data restoration which will be performed, they can click Execute. If the users click Cancel in the process of restoring data to the AH500 series CPU module, the data will not be completely restored. To prevent the AH500 series CPU module from operating incorrectly, the users have to restore the AH500 series CPU module to the factory setting if they do not perform the data restoration again. Besides, the AH500 series CPU module will still performs the data restoration even if the users click Cancel in the process of restoring a backup file in the memory card inserted in the AH500 series CPU module. The users can turn off the AH500 series CPU module to stop the data restoration from being performed. If restoration source/restoration destination contains a password and an ID, the password and 17-11
ISPSoft User Manual the ID will be processed as follows. Data restoration Description a. The ID in the backup file must be the same as the ID in the CPU module, otherwise the data restoration will not be performed. b. If there is a PLC password in the CPU module, the password in the backup file must be the same as the PLC Memory cardCPU module password in the CPU module. Otherwise the data restoration will not be performed. c. If there is no PLC password in the CPU module, and there is a password in the backup file, the system will perform the data restoration, and the password in the backup file will become the PLC password in the CPU. a. The ID in the backup file must be the same as the ID in the CPU module, otherwise the data restoration will not be performed. b. If there is a PLC password in the CPU module, the password in the backup file must be the same as the PLC password in the CPU module. Otherwise the data ComputerCPU module restoration will not be performed, and a message will appear. c. If there is no PLC password in the CPU module, and there is a password in the backup file, the system will perform the data restoration, and the password in the backup file will become the PLC password in the CPU. The ID and the password in the backup file will become the Computer ISPSoft project program ID and the project password in an ISPSoft project. (7) After the data restoration is performed, the users can click Home or Close in the CARD Utility window. 17-12
- Page 546 and 547: ISPSoft User Manual • Linked Devi
- Page 548 and 549: ISPSoft User Manual Related setting
- Page 550 and 551: ISPSoft User Manual The present net
- Page 552 and 553: ISPSoft User Manual Setting area:
- Page 554 and 555: ISPSoft User Manual The indicators
- Page 556 and 557: ISPSoft User Manual Users can type
- Page 558 and 559: ISPSoft User Manual An Ether Link i
- Page 560 and 561: ISPSoft User Manual Information ar
- Page 562 and 563: ISPSoft User Manual (5) Type a data
- Page 564 and 565: ISPSoft User Manual If a specific n
- Page 566 and 567: ISPSoft User Manual • Method 2 Do
- Page 568 and 569: ISPSoft User Manual • Multiple no
- Page 570 and 571: ISPSoft User Manual • Multiple no
- Page 572 and 573: ISPSoft User Manual 16.4.9 Enabling
- Page 574 and 575: ISPSoft User Manual Additional rema
- Page 576 and 577: ISPSoft User Manual 16.4.10 Startin
- Page 578 and 579: ISPSoft User Manual ‣ Method 2 Se
- Page 580 and 581: ISPSoft User Manual After a node is
- Page 582 and 583: ISPSoft User Manual 16.5.2.2 Descri
- Page 584 and 585: ISPSoft User Manual (1) Users have
- Page 586 and 587: Chapter 17 Data Backup and Data Res
- Page 588 and 589: Chapter 17 Data Backup and Data Res
- Page 590 and 591: Chapter 17 Data Backup and Data Res
- Page 592 and 593: Chapter 17 Data Backup and Data Res
- Page 594 and 595: Chapter 17 Data Backup and Data Res
- Page 598 and 599: Appendix A USB Connection Table of
- Page 600 and 601: Appendix A USB Connection Specify a
- Page 602 and 603: Appendix A USB Connection *. The de
- Page 604 and 605: Appendix A USB Connection If the de
- Page 606 and 607: Appendix B Important Points Related
- Page 608 and 609: Appendix B Important Points Related
- Page 610 and 611: Appendix B Important Points Related
- Page 612 and 613: Appendix B Important Points Related
- Page 614 and 615: Appendix C Print Management Tool Ta
- Page 616 and 617: Appendix C Print Management Tool C.
Chapter 17 Data Backup and Data Restoration<br />
which exists in the computer, the file will be overwritten after the data restoration is<br />
peformed.<br />
(4) After the users make sure that the summary in the CARD Utility window is consistent with the<br />
data restoration which will be performed, they can click Execute.<br />
If the users click Cancel in the process of restoring data to the AH500 series CPU module, the<br />
data will not be completely restored. To prevent the AH500 series CPU module from operating<br />
incorrectly, the users have to restore the AH500 series CPU module to the factory setting if<br />
they do not perform the data restoration again. Besides, the AH500 series CPU module will still<br />
performs the data restoration even if the users click Cancel in the process of restoring a<br />
backup file in the memory card inserted in the AH500 series CPU module. The users can turn<br />
off the AH500 series CPU module to stop the data restoration from being performed.<br />
If restoration source/restoration destination contains a password and an ID, the password and<br />
17-11