ISPSoft User Manual
ISPSoft User Manual ISPSoft User Manual
Chapter 2 Starting and Setting 2.4.3.3 Setting Communication Parameters for DirectLink (USB) (1) Users can type a driver name in the Driver Name box. Special marks can not be used except _. (2) Select DirectLink (USB) in the Type drop-down list box in the Connection Setup section. (3) Users can select the number of times the sending of a command is retried if a connection error occurs in the Time of Auto-retry box, and select an interval of retrying the sending of a command in the Time Interval of Auto-retry box. 2.4.3.4 Setting Communication Parameters for Ethernet (1) Users can type a driver name in the Driver Name box. Special marks can not be used except _. (2) Select Ethernet (USB) in the Type drop-down list box in the Connection Setup section. (3) Select a network interface card in the Description drop-down list box. An IP address assigned to a network interface card selected is displayed in the lower left corner of the Ethernet Card section. (4) Owing to the characteristics of Ethernet, a computer can communicate with all devices on a network. Users can create the IP addresses of devices connected to this driver in the IP Address Setting section. ‣ Some devices support the Search function. After users click Search to search for IP addresses, results are displayed in the IP Address Setting section. ‣ After users click Add to add a new IP address to the list of IP addresses in the IP Address Setting section, they can type related information in the IP Address section, the Port Number column, and the Comment column. Users can type the IP address of a device connected in this column. Users can type a communication port number specified. If it is not necessary to specify a 2-41
ISPSoft User Manual communication port number, please use the default communication port number 502. Users can type a comment in this column. Users can not type a device in this column. After users click Search, a device which is found is displayed in this column. ‣ After users select an IP address, they can click Del or press DEL on the keyboard to delete the IP address from the list. (5) Users can select the number of times the sending of a command is retried if a connection error occurs in the Time of Auto-retry box, and select an interval of retrying the sending of a command in the Time Interval of Auto-retry box. *. When the Driver Properties window is opened, the information about the network interface cards in the computer is retrieved once. However, the information in the Description drop-down list box will not be updated. If a network interface card is added to the computer system after the Driver Properties window is opened, the network interface card will not be displayed in the Description drop-down list box. Users have to close the Driver Properties window, and open it again. 2.4.3.5 Setting Communication Parameters for DirectLink (Ethernet) (1) Users can type a driver name in the Driver Name box. Special marks can not be used except _. (2) Select DirectLink (Ethernet) in the Type drop-down list box in the Connection Setup section. (3) Select a network interface card in the Description drop-down list box. An IP address assigned to a network interface card selected is displayed in the lower left corner of the Ethernet Card section. (4) Owing to the characteristics of Ethernet, a computer can communicate with all devices on a network. Users can create the IP addresses of devices connected to this driver in the IP Address Setting section. ‣ Delta human-machine interfaces support the Search function. After users click Search to search for IP addresses, results are displayed in the IP Address Setting section. ‣ After users click Add to add a new IP address to the list of IP addresses in the IP Address Setting section, they can type related information in the IP Address section, the Port 2-42
- Page 4 and 5: Chapter 1 Introduction of the Softw
- Page 6 and 7: Chapter 1 Introduction of the Softw
- Page 8 and 9: Chapter 1 Introduction of the Softw
- Page 10 and 11: Chapter 1 Introduction of the Softw
- Page 12 and 13: Chapter 1 Introduction of the Softw
- Page 14 and 15: Chapter 2 Starting and Setting Tabl
- Page 16 and 17: Chapter 2 Starting and Setting Afte
- Page 18 and 19: Chapter 2 Starting and Setting Win
- Page 20 and 21: Chapter 2 Starting and Setting •
- Page 22 and 23: Chapter 2 Starting and Setting •
- Page 24 and 25: Chapter 2 Starting and Setting they
- Page 26 and 27: Chapter 2 Starting and Setting •
- Page 28 and 29: Chapter 2 Starting and Setting *1.
- Page 30 and 31: Chapter 2 Starting and Setting User
- Page 32 and 33: Chapter 2 Starting and Setting File
- Page 34 and 35: Chapter 2 Starting and Setting Afte
- Page 36 and 37: Chapter 2 Starting and Setting •
- Page 38 and 39: Chapter 2 Starting and Setting Afte
- Page 40 and 41: Chapter 2 Starting and Setting In t
- Page 42 and 43: Chapter 2 Starting and Setting Afte
- Page 44 and 45: Chapter 2 Starting and Setting •
- Page 46 and 47: Chapter 2 Starting and Setting •
- Page 48 and 49: Chapter 2 Starting and Setting *. I
- Page 50 and 51: Chapter 2 Starting and Setting Afte
- Page 52 and 53: Chapter 2 Starting and Setting ‣
- Page 56 and 57: Chapter 2 Starting and Setting Numb
- Page 58 and 59: Chapter 2 Starting and Setting they
- Page 60 and 61: Chapter 2 Starting and Setting (5)
- Page 62 and 63: Chapter 2 Starting and Setting Addi
- Page 64 and 65: Chapter 3 Configuring and Setting a
- Page 66 and 67: ISPSoft User Manual By means of the
- Page 68 and 69: ISPSoft User Manual (6) If the user
- Page 70 and 71: ISPSoft User Manual 3.2 Hardware Co
- Page 72 and 73: ISPSoft User Manual All hardware av
- Page 74 and 75: ISPSoft User Manual • Method 3 (1
- Page 76 and 77: ISPSoft User Manual • AH16AM10N-5
- Page 78 and 79: ISPSoft User Manual *. Please refer
- Page 80 and 81: ISPSoft User Manual 3.2.2.4 Deletin
- Page 82 and 83: ISPSoft User Manual 3.2.2.6 Searchi
- Page 84 and 85: ISPSoft User Manual *. If the Repla
- Page 86 and 87: ISPSoft User Manual There are two w
- Page 88 and 89: ISPSoft User Manual • Method 2 (1
- Page 90 and 91: ISPSoft User Manual *. An extension
- Page 92 and 93: ISPSoft User Manual 3.2.2.12 Replac
- Page 94 and 95: ISPSoft User Manual system configur
- Page 96 and 97: ISPSoft User Manual 3.3 Setting the
- Page 98 and 99: ISPSoft User Manual Users can ident
- Page 100 and 101: ISPSoft User Manual • Enable Remo
- Page 102 and 103: ISPSoft User Manual value and a min
Chapter 2 Starting and Setting<br />
2.4.3.3 Setting Communication Parameters for DirectLink (USB)<br />
(1) <strong>User</strong>s can type a driver name in the Driver Name box. Special marks can not be used except<br />
_.<br />
(2) Select DirectLink (USB) in the Type drop-down list box in the Connection Setup section.<br />
(3) <strong>User</strong>s can select the number of times the sending of a command is retried if a connection error<br />
occurs in the Time of Auto-retry box, and select an interval of retrying the sending of a<br />
command in the Time Interval of Auto-retry box.<br />
2.4.3.4 Setting Communication Parameters for Ethernet<br />
(1) <strong>User</strong>s can type a driver name in the Driver Name box. Special marks can not be used except<br />
_.<br />
(2) Select Ethernet (USB) in the Type drop-down list box in the Connection Setup section.<br />
(3) Select a network interface card in the Description drop-down list box. An IP address assigned<br />
to a network interface card selected is displayed in the lower left corner of the Ethernet Card<br />
section.<br />
(4) Owing to the characteristics of Ethernet, a computer can communicate with all devices on a<br />
network. <strong>User</strong>s can create the IP addresses of devices connected to this driver in the IP<br />
Address Setting section.<br />
‣ Some devices support the Search function. After users click Search to search for IP<br />
addresses, results are displayed in the IP Address Setting section.<br />
‣ After users click Add to add a new IP address to the list of IP addresses in the IP Address<br />
Setting section, they can type related information in the IP Address section, the Port<br />
Number column, and the Comment column.<br />
<strong>User</strong>s can type the IP address of a device connected in this column.<br />
<strong>User</strong>s can type a communication port number specified. If it is not necessary to specify a<br />
2-41