Chapter 15 Password Management and Data Protection<br />

If the subroutine is not protected by a subroutine password, there will be two boxes used to set a<br />

subroutine password in the Subroutine Password Setting window. If the users want to set a<br />

subroutine password, they have to type the same password in the two boxes, and click OK.<br />

If the subroutine is protected by a subroutine password, there will be one box used to unlock the<br />

subroutine password in the Subroutine Password Setting window. If the users want to unlock the<br />

subroutine password, they can type the correct password in the box, and click OK.<br />

The users can only type English letters, numerical digits, and spaces in the window. A POU<br />

password is case-sensitive. After the users set a subroutine password, the subroutine will be<br />

protected by the subroutine password. The window will be closed after the users click Cancel.<br />

15.6 Other Password Protection functions and Data<br />

Protection Functions<br />

15.6.1 Inactivating the Uploading of the Program from a DVP<br />

Series PLC<br />

<strong>User</strong>s can inactivate the uploading of the program from a DVP series PLC. If this function is used,<br />

the uploading of the program from the DVP series PLC will be prohibited. The uploading of the<br />

program from the DVP series PLC will be allowed only after the PLC is restored to the default setting.<br />

Besides, if a PLC password is set in the PLC, it has to be unlocked before this function is used. The<br />

data in the PLC do not need to be protected by a PLC password after the uploading of the program<br />

from the PLC is inactivated, and therefore the users can not set a PLC password.<br />

If the users want to inactivate the uploading of the program from the DVP series PLC, they can click<br />

the PLC menu, point to System Security, and click Program Upload Disable. After the uploading<br />

of the program from the PLC is inactivated, the data in the PLC can not be uploaded. As a result, the<br />

users have to decide whether they need to back the data in the PLC up in advance.<br />