<strong>ISPSoft</strong> <strong>User</strong> <strong>Manual</strong><br />

14.1 Online Monitoring Function<br />

14.1.1 Changing the Operating Status of a PLC<br />

<strong>User</strong>s need to constantly change the operating status of a PLC when they test and debug the<br />

program in the PLC. They can easily change the status of the PLC by means of <strong>ISPSoft</strong>. Before the<br />

operation status of a PLC is changed by means of <strong>ISPSoft</strong>, users have to make sure that <strong>ISPSoft</strong> is<br />

connected to the PLC normally. Please refer to section 2.4 for more information.<br />

After users click Run on the PLC menu or on the toolbar, the PLC will begin to run. The PLC<br />

will stop running after Stop on the PLC menu or on the toolbar is clicked.<br />

If the operating status of a PLC is changed by means of <strong>ISPSoft</strong>, users do not have to consider the<br />

state of the RUN/STOP switch on the PLC. After the operating status of a PLC is changed by means<br />

of <strong>ISPSoft</strong>, users still can change the operating status of the PLC again by means of the RUN/STOP<br />

switch on the PLC.<br />

14.1.2 Online Monitoring Function and Environment<br />

If <strong>ISPSoft</strong> is connected to the PLC normally, users can monitor the execution status of the PLC<br />

through the online monitoring modes. Please refer to section 2.4 for more information about setting<br />

the connection between <strong>ISPSoft</strong> and a PLC.<br />

In <strong>ISPSoft</strong>, there are two monitoring modes. One is the device monitoring mode, and the other is the<br />

program monitoring mode.<br />

Monitoring mode<br />

Description<br />

<strong>User</strong>s can monitor the statuses of the devices in the PLC through<br />

Device monitoring mode<br />

Program monitoring mode<br />

the monitoring table. In this mode, <strong>ISPSoft</strong> only needs to update the<br />

statuses of the devices. The present program in <strong>ISPSoft</strong> does not<br />

need to be the same as the program in the PLC.<br />

In this mode, the operating status of the program is displayed in the<br />

program editing window. As a result, the present program in <strong>ISPSoft</strong><br />

must be the same as the program in the PLC.<br />

*. The device monitoring function can be enabled independently. However, if the program monitoring function is<br />

enabled, the device monitoring function is also enabled.<br />

A fter users click Online Mode on the PLC menu, or on the toolbar, the online monitoring<br />

function will be enabled. The system will also enable the device monitoring mode and the program<br />

monitoring mode.<br />