ISPSoft User Manual
ISPSoft User Manual ISPSoft User Manual
Chapter 13 Auxiliary Editing Tools If the users click Clear All, the values in the Edit File Register Memory window will be cleared to 0. Besides, the users can clear the values on the present page by right-clicking the present page, clicking Select All on the context menu, right-clicking the present page again, clicking Clear as 0 on the context menu. 13-35
ISPSoft User Manual If the users want to clear the values in the cells for a range of file registers on the present page, they can drag across the cells, right-click the present page, and click Clear as 0 on the context menu. After the users click Transfer, the Transfer Setup window will appear. The users can download the values in the table to the PLC, or upload the values in the file registers from the PLC through the window. Before Transfer is clicked, the users have to make sure that ISPSoft is connected to the PLC normally. Please refer to section 2.4 for more information. Select Read form PLC or Write to PLC in the Transmission Type drop-down list box, and then select the All option button or the Part option button. After the setting is complete, the users can click OK. Before the values are written into the registers, users have to make sure that the operation does not affect the system, or cause damage to the system and staff. The values in the Edit File Register Memory window can be saved with the project. If the present window is the Edit File Register Memory window, the values in the Edit Register Memory window will be saved as a wft file whose primary filename is the project name in the folder in which the project (*.isp) is saved after the users click Save on the File menu or the toolbar. If the users want to open the Edit File Register Memory window in the project again, the system will open the wft file in the folder in which the project (*.isp) is saved. If no wft is in the folder in which the project is saved, the values in the Edit File Register Memory window will be 0. Besides, the users can save the values in the Edit File Register Memory window as a wft file in another folder after they click Save As on the File menu. If the users want to open the wft file which was saved previously, they can click Open on the File menu or the toolbar. 13-36
- Page 396 and 397: Chapter 12 Sequential Function Char
- Page 398 and 399: Chapter 12 Sequential Function Char
- Page 400 and 401: Chapter 12 Sequential Function Char
- Page 402 and 403: Chapter 12 Sequential Function Char
- Page 404 and 405: Chapter 12 Sequential Function Char
- Page 406 and 407: Chapter 12 Sequential Function Char
- Page 408 and 409: Chapter 12 Sequential Function Char
- Page 410 and 411: Chapter 12 Sequential Function Char
- Page 412 and 413: Chapter 13 Auxiliary Editing Tools
- Page 414 and 415: Chapter 13 Auxiliary Editing Tools
- Page 416 and 417: Chapter 13 Auxiliary Editing Tools
- Page 418 and 419: Chapter 13 Auxiliary Editing Tools
- Page 420 and 421: Chapter 13 Auxiliary Editing Tools
- Page 422 and 423: Chapter 13 Auxiliary Editing Tools
- Page 424 and 425: Chapter 13 Auxiliary Editing Tools
- Page 426 and 427: Chapter 13 Auxiliary Editing Tools
- Page 428 and 429: Chapter 13 Auxiliary Editing Tools
- Page 430 and 431: Chapter 13 Auxiliary Editing Tools
- Page 432 and 433: Chapter 13 Auxiliary Editing Tools
- Page 434 and 435: Chapter 13 Auxiliary Editing Tools
- Page 436 and 437: Chapter 13 Auxiliary Editing Tools
- Page 438 and 439: Chapter 13 Auxiliary Editing Tools
- Page 440 and 441: Chapter 13 Auxiliary Editing Tools
- Page 442 and 443: Chapter 13 Auxiliary Editing Tools
- Page 444 and 445: Chapter 13 Auxiliary Editing Tools
- Page 448 and 449: Chapter 13 Auxiliary Editing Tools
- Page 450 and 451: Chapter 13 Auxiliary Editing Tools
- Page 452 and 453: Chapter 14 Test Tools and Debugging
- Page 454 and 455: Chapter 14 Test Tools and Debugging
- Page 456 and 457: Chapter 14 Test Tools and Debugging
- Page 458 and 459: Chapter 14 Test Tools and Debugging
- Page 460 and 461: Chapter 14 Test Tools and Debugging
- Page 462 and 463: Chapter 14 Test Tools and Debugging
- Page 464 and 465: Chapter 14 Test Tools and Debugging
- Page 466 and 467: Chapter 14 Test Tools and Debugging
- Page 468 and 469: Chapter 14 Test Tools and Debugging
- Page 470 and 471: Chapter 14 Test Tools and Debugging
- Page 472 and 473: Chapter 14 Test Tools and Debugging
- Page 474 and 475: Chapter 14 Test Tools and Debugging
- Page 476 and 477: Chapter 14 Test Tools and Debugging
- Page 478 and 479: Chapter 14 Test Tools and Debugging
- Page 480 and 481: Chapter 14 Test Tools and Debugging
- Page 482 and 483: Chapter 14 Test Tools and Debugging
- Page 484 and 485: Chapter 14 Test Tools and Debugging
- Page 486 and 487: Chapter 14 Test Tools and Debugging
- Page 488 and 489: Chapter 15 Password Management and
- Page 490 and 491: Chapter 15 Password Management and
- Page 492 and 493: Chapter 15 Password Management and
- Page 494 and 495: Chapter 15 Password Management and
Chapter 13 Auxiliary Editing Tools<br />
If the users click Clear All, the values in the Edit File Register Memory window will be cleared to 0.<br />
Besides, the users can clear the values on the present page by right-clicking the present page,<br />
clicking Select All on the context menu, right-clicking the present page again, clicking Clear as 0 on<br />
the context menu.<br />
13-35