<strong>ISPSoft</strong> <strong>User</strong> <strong>Manual</strong><br />

inlet will be in the outlet, and the clamp from which the plate made its exit will receive another plate.<br />

During the whole process, a plate enters the inlet independently, and the plate in the outlet makes its<br />

exit from the outlet independently. However, the rotator does not rotate independently.<br />

When the system begins to operate, the cylinders under the clamps open the clamps. After the<br />

clamps are opened, the system will send readiness signals. After the readiness signals are sent, a<br />

plate will enter the inlet, and the plate in the outlet will make its exit from the outlet.<br />

After a plate enters the inlet, and the plate in the outlet makes its exit from the outlet, the system will<br />

receive completion signals, the corresponding readiness signals will be set to OFF, and the clamps<br />

will be closed. After the system makes sure that the clamps are closed, the system will send a<br />

trigger signal. After the rotator rotates 180 degrees, and the system receives a completion signal,<br />

the next cycle will begin.<br />