<strong>ISPSoft</strong> <strong>User</strong> <strong>Manual</strong><br />

• Compile<br />

Click Compile on the Compile menu, or<br />

on the toolbar.<br />

After the check is complete, the Compile Message page shows the result related to the check. If<br />

there is any error in the project, the Compile Message page will show the related message. After<br />

the message is clicked, the system will automatically lead users to the place where the error occurs.<br />

The users can enable the Check function or the Compile function after the error is eliminated.<br />

4.6 Testing and Debugging a Program<br />

4.6.1 Creating a Connection<br />

Before a program and parameters are downloaded to a PLC or monitored online, <strong>ISPSoft</strong> must be<br />

connected to the PLC. In this example, <strong>ISPSoft</strong> is connected to the CPU module AHCPU530-EN<br />

through a USB cable. Please refer to section 2.4 for more information about connecting <strong>ISPSoft</strong> to a<br />

PLC in other ways. Please refer to operation manuals for more information about wiring.<br />

Those who have connected <strong>ISPSoft</strong> to a PLC successfully in accordance with the contents of<br />

section 2.4 can skip this section.<br />

(1) Install the modules on the main backplane in accordance with the hardware configuration in<br />

HWCONFIG. Make sure that the wiring is correct, and then power the CPU module.<br />

(2) Connect the CPU module to the computer through a USB cable. If the USB driver for the<br />

AH500 series CPU module has been installed on the computer, Delta PLC will appear in the<br />

Device Manager Window, and a port number will be assigned to Delta PLC. Please refer to<br />

appendix A for more information about installing a USB driver.<br />

(3) Make sure that COMMGR is started, and the icon representing COMMGR is displayed on the<br />

system tray. If the icon representing COMMGR is not displayed on the system tray, users can<br />

start COMMGR by clicking the shortcut on the Start menu (Start>Programs>Delta Industrial<br />

4-24