different from the actual hardware configuration.<br />

Next, I/O Scan is clicked. The scan result will be the same as the actual hardware configuration.<br />

After AH16AN01R-5A (installed in slot 1) is double-clicked to open the Parameter Setting window,<br />

users will find that the parameter in the module is assigned the default value. The value of the<br />

parameter is different from the value of the parameter previously downloaded to the CPU module,<br />

that is to say, only the hardware configuration will be scanned after I/O Scan is clicked.<br />

Then, Upload is clicked. After the uploading is complete, users will find that the hardware<br />

configuration and the parameters in the modules which are uploaded are the same as the hardware<br />

configuration and the parameters in the modules which were previously downloaded to the CPU<br />

module. In other words, after Upload is clicked, the system parameters in the CPU module will read,<br />

and the actual hardware configuration will not be uploaded.<br />

Next, I/O Scan is clicked, and the scan result is downloaded to the CPU module. The BUS FAULT<br />

LED indicator on the CPU module will be OFF, that is to say, the hardware configuration in the CPU<br />

module is the same as the actual hardware configuration.<br />

3.5.6 Online Diagnosis<br />

<strong>User</strong>s not only can configure modules in HWCONFIG offline, but also can operate and inspect the<br />

system through the Online Mode function if <strong>ISPSoft</strong> is connected to the CPU module. Owing to the<br />

fact that HWCONFIG adopts the communication setting in <strong>ISPSoft</strong>, users have to make sure that<br />

<strong>ISPSoft</strong> is connected to the CPU module normally before the Online Mode function is enabled.<br />

Please refer to section 2.4 for more information about communication setting. If users want to<br />

enable the Online Mode function, but the name of the CPU module is different from the name<br />

attached to the model in the project management area, the system will remind the users to check<br />

the name of the CPU module and the name attached to the model in the project management area.<br />

Please refer to section 3.3.2.1 for more information.<br />

3.5.6.1 Online Mode<br />

(1) After users click Online Mode on the Option menu, or on the toolbar, the hardware<br />

configuration will be in the online mode. If the users click<br />

configuration will not be in the online mode.<br />

again, the hardware<br />