Chapter 3 Configuring and Setting a PLC System<br />

automatically send the email to user_1@delta.com.tw, and user_4@delta.com.tw.<br />

*. The parameters set in HWCONFIG must be downloaded to the CPU module so that they can take effect. (Please<br />

refer to section 3.3.6 or section 3.5.4 for more information.)<br />

3.3.5.6 Ethernet─Advance: Socket<br />

After users click the Ethernet─Advance tab at the top of the window, and the Socket tab at the<br />

bottom of the window, they can set the parameters for sockets through which data is transmitted.<br />

This function has to be used with specific applied instructions. Please refer to AH500 Programming<br />

<strong>Manual</strong> for more information.<br />

Sockets will not be introduced here. Please refer to related documents or manuals for more<br />

information about sockets.<br />

An AH500 system supports the transmission of data between the CPU module and other CPU<br />

modules or devices by means of the creation of sockets, and supports TCP and UDP. <strong>User</strong>s can set<br />

eight TCP connections and eight UDP connections. If users want to set a TCP connection, they<br />

have to select the Enable Socket Function checkbox, and double-click an item in the TCP Socket<br />

Connection table to open the TCP Socket Configuration window. If the users want to set a UDP<br />

connection, they have to select the Enable Socket Function checkbox, and double-click an item in<br />

the UDP Socket Connection table to open the UD Socket Configuration window.<br />

3-50