<strong>Household</strong> <strong>Water</strong> <strong>Treatment</strong> <strong>and</strong> <strong>Safe</strong> <strong>Storage</strong><br />
Product Sheet: Guardian Solid Form Biocide<br />
(SFB) Rope<br />
<strong>Storage</strong>:<br />
Maintenance:<br />
Cleaning is recommended if the Guardian SFB Rope is stored<br />
for more than a year without use.<br />
Clean every 4 months if the water source has low turbidity, total<br />
dissolved solids (TDS) <strong>and</strong> hardness. However, when hardness<br />
is higher than 400 ppm <strong>and</strong> TDS is higher than 600 ppm, it is<br />
recommended to clean every 3 months. If turbidity is higher than<br />
30 NTU, the Guardian SFB Rope needs to be cleaned every 2<br />
months.<br />
To clean, soak the Guardian SFB Rope in cleaning solution for 1<br />
hour. To make the cleaning solution, use the juice of 1 lemon or<br />
3 grams vitamin C powder or 4 tablespoons vinegar per 1 litre of<br />
water. Then rinse the Guardian SFB Rope with non-turbid water,<br />
<strong>and</strong> return to use.<br />
<strong>Treatment</strong> Efficiency*<br />
Bacteria Viruses Protozoa Helminths Turbidity Chemicals<br />
Laboratory 99.9999% 1 99.9999% 3 0% 0% 0% 0%<br />
Field 99.9999% 2 N/A 0% 0% 0% 0%<br />
* Efficiency depends on contact time <strong>and</strong> water conditions. These results are after 90 minutes <strong>and</strong> the initial water<br />
conditions were: pH= 6.3, Turbidity= 0.4 NTU, hardness= 284mg/L TDS= 360 mg/L <strong>and</strong> fluoride= 0.35 mg/L. Data<br />
provided by H2O, Inc.<br />
1 E.coli removal. Tested by EMS Lab in India, reported by H2O, Inc.<br />
2<br />
Tested in the field by Oxfam, reported by H20 Inc. These results are after 120-360 minutes contact time for three<br />
different water sources <strong>and</strong> stirring every 30 minutes.<br />
3<br />
Colipaghe-MS2 removal. Tested by EMS Lab in India, reported by H2O, Inc.<br />
N/A: Not available<br />
Further Information<br />
H2O <strong>Water</strong> Solutions Inc.<br />
760 Hobart Street<br />
Menlo Park, CA 94025 USA<br />
Tel: 1.650.325.5321<br />
Website: www.htwentyinc.com<br />
(Credit: www.htwentyinc.com)<br />
CAWST (Centre for Affordable <strong>Water</strong> <strong>and</strong> Sanitation Technology)<br />
Wellness through <strong>Water</strong>.... Empowering People Globally<br />
Calgary, Alberta, Canada<br />
Website: www.cawst.org<br />
Email: cawst@cawst.org<br />
Last Update: April 2011