19.0. SYSTEM CONTAMINATION PURGING PROCEDURE (Cont.):<br />
19.5.4. Install hose adapter fitting and attach low-pressure hose.<br />
!<br />
NOTE: ATTACH DISCHARGE TUBE TO FLUID CONTAINER TO<br />
ELIMINATE FLUID SPILLING.<br />
19.6. FLUSHING CYCLE<br />
19.6.1. Press the AIR PURGE / RESET pushbutton located on the front of<br />
<strong>Chip</strong>BLASTER’s electrical enclosure.<br />
19.6.2. Continue pressing the AIR PURGE /RESET pushbutton until 5 gallon container<br />
is full.<br />
19.6.3. Close the Air Bleeder Valves located on the upper portion of the filter.<br />
19.6.4. Press the AIR PURGE /RESET pushbutton again to continue flushing cycle. Fill<br />
the 5-gallon container an addition (3) times to complete the flushing cycle.<br />
19.7. REPLACE ALL PLUMBING FITTINGS AND PANELS TO THEIR<br />
ORIGINAL CONFIGURATION.<br />
REPLACE ALL GUARDS BEFORE OPERATING <strong>Chip</strong>BLASTER<br />
Any questions on the Contamination Purging Procedures, please contact the<br />
<strong>Chip</strong>BLASTER Service Department at (814) 724-6278. Have the model and serial<br />
number of your <strong>Chip</strong>BLASTER unit.<br />