<strong>Chip</strong>BLASTER, Inc. 66<br />

19.0. SYSTEM CONTAMINATION PURGING PROCEDURE (Cont.):<br />

19.5.4. Install hose adapter fitting and attach low-pressure hose.<br />

!<br />

NOTE: ATTACH DISCHARGE TUBE TO FLUID CONTAINER TO<br />

ELIMINATE FLUID SPILLING.<br />

19.6. FLUSHING CYCLE<br />

19.6.1. Press the AIR PURGE / RESET pushbutton located on the front of<br />

<strong>Chip</strong>BLASTER’s electrical enclosure.<br />

19.6.2. Continue pressing the AIR PURGE /RESET pushbutton until 5 gallon container<br />

is full.<br />

19.6.3. Close the Air Bleeder Valves located on the upper portion of the filter.<br />

19.6.4. Press the AIR PURGE /RESET pushbutton again to continue flushing cycle. Fill<br />

the 5-gallon container an addition (3) times to complete the flushing cycle.<br />

19.7. REPLACE ALL PLUMBING FITTINGS AND PANELS TO THEIR<br />

ORIGINAL CONFIGURATION.<br />

REPLACE ALL GUARDS BEFORE OPERATING <strong>Chip</strong>BLASTER<br />

Any questions on the Contamination Purging Procedures, please contact the<br />

<strong>Chip</strong>BLASTER Service Department at (814) 724-6278. Have the model and serial<br />

number of your <strong>Chip</strong>BLASTER unit.<br />