<strong>Chip</strong>BLASTER, Inc. 64<br />
19.0. SYSTEM CONTAMINATION PURGING PROCEDURE:<br />
19.1. Tools Required:<br />
19.1.1. 6mm Hex Head Wrench<br />
19.1.2. 7/8” Wrench (For Unit Without Pressure Switch Option)<br />
19.1.3. 1-1/4” Wrench (For Unit With Pressure Switch Option)<br />
19.1.4. 5 Gallon Fluid Container<br />
19.1.5. Section of Low Pressure Hose<br />
19.1.6. Adapter Fitting ( ½” SAE to Hose Connection)<br />
19.1.7. Small Phillips Screw Driver (For Unit With Pressure Switch Option)<br />
19.2. Change Filter Bag:<br />
19.2.1. Shut off all power to machine.<br />
19.2.2. Open the Air Bleeder Valves located on the upper portion of the filter and on<br />
post filter to release any pressure on filter housing.<br />
19.2.3 Visually check filter inlet and outlet pressure gauges for zero pressure.<br />
!<br />
IF THERE IS PRESSURE PRESENT DO NOT OPEN FILTER HOUSING<br />
SEEK ASSISTANCE FROM QUALIFIED MAINTENANCE<br />
PERSONNEL TO RELIEVE PRESSURE.<br />
19.2.4. Remove Filter Housing Lid.<br />
19.2.5. Remove and inspect the “O-ring.<br />
19.2.6. Remove Filter Displacement Device or Optional Hydrocyclonic Filter.<br />
19.2.7. Remove and discard old filter.<br />
DO NOT POUR REMAINING COOLANT FROM FILTER BAG BACK IN<br />
THE VESSEL OR CONTAMINATES WILL ENTER THE SYSTEM.<br />
19.2.8 Replace with a new filter bag, making sure that it is seated firmly against<br />
the top of the Filter Basket.<br />
19.2.9 Replace Filter Displacement Device or Optional Hydrocyclonic Filter.<br />
19.2.10 Fill filter housing with coolant.<br />
19.2.11 Replace the “O-ring, making sure it is properly seated in the rim of the Filter<br />
Body.<br />
19.2.10 Replace the lid, being careful not to displace “O-ring.<br />
19.2.11 Torque all Filter Lid fasteners to 360-480 in-lbs.(40.6 – 54.2 Nm)<br />
19.3 Remove access panel:<br />
19.3.1. Remove rear access panel from <strong>Chip</strong>BLASTER unit (Panel opposite to the<br />
Gauge Panel).<br />
19.4 For units without pressure switch:<br />
19.4.1. Remove SAE pipe plug fitting from the high-pressure manifold. This<br />
fitting is located on the lower right side of the high-pressure manifold. See<br />
Figure 8.<br />