<strong>Chip</strong>BLASTER, Inc. 60<br />
17.0. HIGH PRESSURE PUMP REPLACEMENT (SINGLE PUMP):<br />
(Cont.):<br />
17.3. THE REPLACEMENT PUMP:<br />
17.3.1. Remove the low pressure hose, high pressure hose, oil line hose, black<br />
drain line lines and the pulley from the defective pump. Remove the 4 bolts that<br />
secure the pump to the rails and remove the defective pump.<br />
17.3.2. Install the replacement pump on the rails using the hardware removed in<br />
step 17.3.1. above.<br />
17.3.3. Install the pulley (DO NOT TIGHTEN), low pressure hose, high pressure hose,<br />
oil line hose, black drain line on the replacement pump. NOTE: The upper port<br />
is the high pressure port and the lower port is the low pressure port.<br />
17.3.4. Torque all of the hex and square plumbing fittings to 36ft/lbs. (48.8 Nm).<br />
Using a straightedge to line up the pulleys on the pump and motor. Tighten pulley<br />
set screws.<br />
17.3.5. Torque bushing bolts to 108 in lb (12.2 Nm).<br />
17.0